The aim of the paper is to present the possibilities and limitations of using the Digital Image Correlation systems. In order to assess the measurement inaccuracies the measuring volume 1250 × 1100 mm was analysed using two cameras with sensor resolution 6 megapixels. It was stated very good accuracy of the line segment length change. It causes that observation of crack widths can be considered as precisely. Some practical information concern how determine the compatibility between crack width measured traditionally and by using DIC are given. In the second part of the paper the results of the tests concerning capacity of interface between two concrete casting at the same time were presented. Use of the optical measurement system Aramis enables the analysis of the deformation, determination of failure mode of the tested specimens and limit displacement between edges of the interface.
The results of experimental test of nine thickset reinforced concrete slabs in punching are presented in the this paper. The aim of the tests was verifi cation of the Eurocode EC 2 procedure, by which the ultimate shear stresses v Rd,c depend on the slenderness of the slab. Besides of the performed tests results, the analysis of the foreign investigation of the fundaments is also included. The test results, as well as other tests, show the correctness of the function assumed in Eurocode 2, which gives correlation between ultimate stresses v Rd,c and shear slenderness.
In the paper the results of experimental investigations concerning flat slabs made from reinforced lightweight concrete with sintered fly ash aggregate CERTYD were presented. In the research program 6 models made in a natural scale were included. The main variable parameter was slab longitudinal reinforcement ratio. The aim of investigation was the experimental verification of efficiency of double-headed studs as punching shear reinforcement. In the existing technical approvals such kind of reinforcement was allowed only in normal concrete slabs. It was demonstrated that double-headed studs can be an effective transverse reinforcement of lightweight aggregate concrete slabs. The use of double-headed studs resulted in increase in the ultimate load from 19% to 44%, depending on the slab reinforcement ratio which ranged from 0.5% to 1.2%. The comparative analysis showed that the Eurocode 2 provisions were conservative in relation to the experimental results, which were on average 42% higher than the theoretical ones however with a very low 7% coefficient of variation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.