Paciente YB, 50 anos, sexo feminino, com hipotireoidismo, disfunção ventricular esquerda grave, ventrículo esquerdo não compactado e taquicardia ventricular mal tolerada, submetida a implante de cardioversor-des brilador implantável (CDI) de dupla câmara em fevereiro de 2012 com sucesso (gerador Secura DR Medtronic, eletrodo atrial 4076 Medtronic e eletrodo ventricular Sprint Quattro 6947 Medtronic). Retorna assintomática nove meses após o implante para avaliação de rotina.
Patient OG, 62 years, with arrhythmogenic cardiomyopathy in the right ventricle and low-tolerated sustained tachycardia, user of an implantable ventricular single-chamber cardiovascular defibrillator (ICD), returned asymptomatic for routine evaluation. Th ere was no registry of sustained arrhythmia, and the limits of stimulation and sensitivity were checked and were appropriate. However, facing the device’s telemetry, it was detected lack of sensitivity in a ventricular extra-systole.
Paciente OG, 62 anos, com cardiomiopatia arritmogênica do ventrículo direito e taquicardia ventricular sustentada mal tolerada, portador de cardioversor desfi brilador implantável (CDI) de câmara única ventricular, retornou assintomático para avaliação de rotina. Não havia registro de arritmias sustentadas, e os limiares de estimulação e sensibilidade foram checados e estavam adequados (Fig. 1). No entanto, diante da telemetria do dispositivo, foi identifi cada uma falha de sensibilidade de uma extra-sístole ventricular (Fig. 2).Desse modo, diante da possibilidade de que essa falha pudesse gerar falha de detecção de uma taquicardia ventricular lenta (Fig. 3), o autoganho de sensibilidade do CDI foi modifi cado, com correção da falha de sensibilidade intermitente da extra-sístole.Figura 1. Medidas eletrofi siológicas do cardioversor-desfi brilador na avaliação inicial e ausência de arrtmias ventriculares documentadas.
Patient YB, 50 years old, female, with hypothyroidism, severe left ventricular dysfunction, uncompressed left ventricle and poorly tolerated ventricular tachycardia, submitted to implantation of a dual chamber implantable cardioverter-defibrillator (ICD) in February 2012 (generator Secura DR Medtronic, 4076 Medtronic atrial electrode, and Sprint Quattro 6947 Medtronic ventricular electrode). Returns asymptomatic nine months after the implant for routine evaluation.
Paciente DT, 23 anos, sexo feminino, com transposição corrigida de grandes artérias, bloqueio atrioventricular total com QRS estreito (Fig. 1), submetida a implante de marcapasso bicameral aos 13 anos, com troca de gerador há três anos. Possui boa capacidade funcional, mas queixa-se de fadiga diante de esforços intensos.
Patient T.D., 23 years old, female, with corrected transposition of the great arteries, complete atrioventricular block with narrow QRS, submitted to bicameral pacemaker implantation at 13 years of age, with generator replacement three years ago. She has a good functional capacity, but complains of fatigue in the face of intense effort.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.