We present a rheometer that combines the possibility to perform in-situ X-ray experiments with a precise and locally controlled uniaxial extensional flow. It thus allows to study the crystallization kinetics and morphology evolution combined with the rheological response to the applied flow field. A constant uniaxial deformation rate is ensured thanks to a fast control scheme that drives the simultaneous movement of the top and bottom plate during a pulling experiment. A laser micrometer measures the time evolution of the smallest diameter, where the highest stress is concentrated. The rheometer has a copper temperature-controlled oven with the ability to reach 250 • C and a N 2 connection to create an inert atmosphere during the experiments. The innovation of our rheometer is the fixed location of the midfilament position, which is possible because of the simultaneous movement of the two end plates. The copper oven has been constructed with four ad-hoc windows: two glass windows for laser access and two kapton windows for X-ray access.The key feature is the ability to perfectly align the midfilament of the sample to the laser micrometer and to the incoming X-ray beam in a synchrotron radiation facility, allowing to investigate structure and morphologies developed during extensional flow. The rheological response measured with our rheometer for LDPE is in agreement with the linear viscoelastic envelope and with the results obtained from existing extensional rheometers.To demonstrate the capability of the instrument we have performed in-situ time-resolved X-ray experiments on LDPE samples exhibiting extensional flow-induced crystallization.
We present a unique laser sintering setup that allows real time studies of the structural evolution during laser sintering of polymer particles. The device incorporates the main features of classical selective laser sintering (SLS) machines for 3D printing of polymers, and at the same time allows in-situ visualization of the sintering dynamics with optical microscopy as well as X-ray scattering.A main feature of the setup is the fact that it provides local access to one particle-particle bridge during sintering. In addition, due to the small scale of the device and the specific laser arrangement process parameters such as temperature, laser energy, laser pulse duration and spot size can be precisely controlled. The sample chamber provides heating up to 360 ºC, which allows for sintering of commodity as well as high performance polymers. The latter parameters are controlled by the use of a visible light laser combined with an acousto-optic modulator for pulsing, which allows small and precise spot sizes and pulse times and pulse energies as low as 500 μs and 17 μJ. The macrostructural evolution of the particle bridge during sintering is followed via optical imaging at high speed and resolution. Placing the setup in a high flux synchrotron radiation with a fast detector, simultaneously allows in-situ time-resolved X-ray characterizations. To demonstrate the capabilities of the device, we studied the laser sintering of two spherical PA12 particles. The setup provides crucial real-time information concerning the sintering dynamics as well as crystallization kinetics, which was not accessible up to now. a
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.