Advances in precision molecular imaging promise to transform our ability to detect, diagnose and treat disease. Here, we describe the engineering and validation of a new cystine knot peptide (knottin) that selectively recognizes human integrin αvβ6 with single-digit nanomolar affinity. We solve its 3D structure by NMR and x-ray crystallography and validate leads with 3 different radiolabels in pre-clinical models of cancer. We evaluate the lead tracer’s safety, biodistribution and pharmacokinetics in healthy human volunteers, and show its ability to detect multiple cancers (pancreatic, cervical and lung) in patients at two study locations. Additionally, we demonstrate that the knottin PET tracers can also detect fibrotic lung disease in idiopathic pulmonary fibrosis patients. Our results indicate that these cystine knot PET tracers may have potential utility in multiple disease states that are associated with upregulation of integrin αvβ6.
Dose-adjusted-EPOCH-R obviates the need for radiotherapy in most patients with primary mediastinal B-cell lymphoma. End-of-treatment PET, however, does not accurately identify patients at risk of treatment failure, thereby confounding clinical decision making. To define the role of PET in primary mediastinal B-cell lymphoma following dose-adjusted-EPOCH-R, we extended enrollment and follow up on our published phase II trial and independent series. Ninety-three patients received dose-adjusted-EPOCH-R without radiotherapy. End-of-treatment PET was performed in 80 patients, of whom 57 received 144 serial scans. One nuclear medicine physician from each institution blindly reviewed all scans from their respective institution. End-of-treatment PET was negative (Deauville 1-3) in 55 (69%) patients with one treatment failure (8-year event-free and overall survival of 96.0% and 97.7%). Among 25 (31%) patients with a positive (Deauville 4-5) end-of-treatment PET, there were 5 (20%) treatment failures (8-year event-free and overall survival of 71.1% and 84.3%). Linear regression analysis of serial scans showed a significant decrease in SUVmax in positive end-of-treatment PET non-progressors compared to an increase in treatment failures. Among 6 treatment failures, the median end-of-treatment SUVmax was 15.4 (range, 1.9-21.3), and 4 achieved long-term remission with salvage therapy. Virtually all patients with a negative end-of-treatment PET following dose-adjusted-EPOCH-R achieved durable remissions and should not receive radiotherapy. Among patients with a positive end-of-treatment PET, only 5/25 (20%) had treatment-failure. Serial PET imaging distinguished end-of-treatment PET positive patients without treatment failure, thereby reducing unnecessary radiotherapy by 80%, and should be considered in all patients with an initial positive PET following dose-adjusted-EPOCH-R (clinicaltrials.gov identifier 00001337).
Gastrin-releasing peptide receptors (GRPRs), part of the bombesin (BBN) family, are aberrantly overexpressed in many cancers, including those of the breast, prostate, pancreas, and lung, and therefore present an attractive target for cancer diagnosis and therapy. Different bombesin analogs have been radiolabeled and used for imaging diagnosis, staging, evaluation of biochemical recurrence, and assessment of metastatic disease in patients with prostate cancer. Recently, interest has shifted from BBN-like receptor agonists to antagonists, because the latter does not induce adverse effects and demonstrate superior in vivo pharmacokinetics. We review the preclinical and clinical literatures on the use of GRPRs as targets for imaging and therapy of prostate cancer, with a focus on the newer developments and theranostic potential of GRPR peptides.
Purpose To investigate whether the evaluation of tumors, lymphoid cell-rich organs, and immune-related adverse events (IRAE) with 18F-FDG PET/CT can predict the efficacy and outcome of immunotherapy. Methods Forty patients who underwent 18F-FDG-PET/CT scans before and after therapy with immune checkpoint inhibitors from December 2013 to December 2016 were retrospectively enrolled (malignant melanoma, n = 21; malignant lymphoma, n = 11; renal cell carcinoma, n = 8). SUVmax of the baseline and first restaging scans were evaluated in tumors, spleen, bone marrow, thyroid and pituitary glands, and were correlated to best overall response in the first year after therapy; IRAE-affected areas were also evaluated. Results Interval change between the baseline and first restaging scans showed that patients with a clinical benefit had a significant decrease in tumor parameters (P < 0.001). All patients with an increase of SUVmax in the thyroid of more than 1.5 (n = 5) on the first restaging scan had a complete response (CR) in 1 year. Patients with CR within 1 year (n = 22) were significantly associated with a favorable long-term outcome (P = 0.002). Nine patients with IRAE findings had CR at final evaluation. Among IRAE, thyroiditis was seen significantly earlier than arthritis (P = 0.040). Conclusions The decrease of tumor parameters at early time-point PET scans was seen in patients with immunotherapy who had clinical benefit within 1 year. PET-detectable IRAE was useful for prediction of a favorable outcome. Early development of thyroiditis may particularly represent an early response indicator to immunotherapy.
Rationale: Novel radiopharmaceuticals for positron emission tomography (PET) are evaluated for the diagnosis of biochemically recurrent prostate cancer (BCR PC). Here, we compare the gastrin releasing peptide receptors (GRPR) -targeting 68 Ga-RM2 with the prostate specific membrane antigen (PSMA) -targeting 68 Ga-PSMA11 and 18 F-DCFPyL.Methods: Fifty patients had both 68 Ga-RM2 PET/MRI and 68 Ga-PSMA11 PET/CT (n=23) or 18 F-DCFPyL PET/CT (n=27) at an interval ranging from 1 to 60 days (mean±SD: 15.8±17.7).Maximum standardized uptake values (SUV max ) were collected for all lesions.Results: RM2 PET was positive in 35 and negative in 15 of the 50 patients. PSMA PET was positive in 37 and negative in 13 of the 50 patients. Both scans detected 70 lesions in 32 patients.Forty-three lesions in 18 patients were identified only on one scan: 68 Ga-RM2 detected 7 more lesions in 4 patients, while PSMA detected 36 more lesions in 13 patients.Conclusions: 68 Ga-RM2 remains a valuable radiopharmaceutical even when compared with the more widely used 68 Ga-PSMA11/ 18 F-DCFPyL in the evaluation of BCR PC. Larger studies are needed to verify that identifying patients for whom these two classes of radiopharmaceuticals are complementary may ultimately allow for personalized medicine.
BackgroundA newly introduced PET/CT scanner (Discovery Meaningful Insights—DMI, GE Healthcare) includes the silicon photomultiplier (SiPM) with time-of-flight (TOF) technology first used in the GE SIGNA PET/MRI. In this study, we investigated the impact of various acquisition times on image quality using this SiPM-based PET/CT.MethodsWe reviewed data from 58 participants with cancer who were scanned using the DMI PET/CT scanner. The administered dosages ranged 295.3–429.9 MBq (mean ± SD 356.3 ± 37.4) and imaging started at 71–142 min (mean ± SD 101.41 ± 17.52) after administration of the radiopharmaceutical. The patients’ BMI ranged 19.79–46.16 (mean ± SD 26.55 ± 5.53). We retrospectively reconstructed the raw TOF data at 30, 60, 90, and 120 s/bed and at the standard image acquisition time per clinical protocol (180 or 210 s/bed depending on BMI). Each reconstruction was reviewed blindly by two nuclear medicine physicians and scored 1–5 (1—poor, 5—excellent quality). The liver signal-to-noise ratio (SNR) was used as a quantitative measure of image quality.ResultsThe average scores ± SD of the readers were 2.61 ± 0.83, 3.70 ± 0.92, 4.36 ± 0.82, 4.82 ± 0.39, and 4.91 ± 0.91 for the 30, 60, 90, and 120 s/bed and at standard acquisition time, respectively. Inter-reader agreement on image quality assessment was good, with a weighted kappa of 0.80 (95% CI 0.72–0.81). In the evaluation of the effects of time per bed acquisition on semi-quantitative measurements, we found that the only time point significantly different from the standard time were 30 and 60 s (both with P < 0.001). The effects of dose and BMI were not statistically significant (P = 0.195 and 0.098, respectively). There was a significant positive effect of time on SNR (P < 0.001), as well as a significant negative effect of weight (P < 0.001).ConclusionsOur results suggest that despite significant delays from injection to imaging (due to comparison with standard PET/CT) compared to standard clinical operations and even in a population with average BMI > 25, images can be acquired as fast as 90 s/bed using the SiPM PET/CT and still result in very good image quality (average score > 4).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.