Diffusion-weighted (Dw) imaging has for a number of years been a diagnostic tool in the field of neuroradiology, yet only since the end of the 1990s, with the introduction of echoplanar imaging (EPI) and the use of sequences capable of performing diffusion studies during a single breath hold, has it found diagnostic applications at the level of the abdomen. The inherent sensitivity to motion and the magnetic susceptibility of Dw sequences nonetheless still create problems in the study of the abdomen due to artefacts caused by the heartbeat and intestinal peristalsis, as well as the presence of various parenchymal-gas interfaces. With regard to focal liver lesions, a review of the literature reveals that Dw imaging is able to differentiate lesions with high water content (cysts and angiomas) from solid lesions. With regard to the latter, although there are differences between benign forms [focal nodular hyperplasia (FNH), adenoma] and malignant forms [metastasis, hepatocellular carcinoma (HCC)] in their apparent diffusion coefficient (ADC) in the average values for histological type, there is a significant overlap in values when lesions are assessed individually, with the consequent problem of their correct identification. One promising aspect is the possibility of quantifying the degree of fibrosis in patients with chronic liver disease and cirrhosis given that the deposit of collagen fibres "restricts" the motion of water molecules and therefore reduces ADC values. However, even in this field, studies can only be considered preliminary and far from real clinical applications. The retroperitoneum is less affected by motion artefacts and similarly deserves the attention of Dw imaging. Here it is possible to differentiate mucin-producing tumours of the pancreas from pseudocystic forms on the basis of ADC values even though the limited spatial resolution of Dw imaging does not enable the identification of small lesions. Dw imaging may be applied to the study of the kidney to differentiate hydronephrosis from pyonephrosis and with regard to tumours, solid from pseudocystic forms. In addition, given that renal parenchyma has significantly variable ADC values on the basis of the anatomic section and physiological conditions, the possibility of assessing functional alterations is currently being studied. Indeed, a good correlation has been found between ADC values and glomerular filtration rate. With regard to musculoskeletal applications, the absence of motion artefacts in the regions studied has enabled the development of sequences less sensitive to magnetic susceptibility and with greater spatial resolution than EPI. Attempts have therefore been made to use Dw imaging in the characterization of soft-tissue tumours although the findings so far have been disputed. Greater agreement has been found regarding sensitivity of the technique in assessing response of these tumours to chemotherapy: tumour necrosis is thought to increase ADC whereas the persistence of vital neoplastic tissue tends to lower it. One of the most pr...
Purpose: The Italian Registry of Contrast Material use in Cardiac Computed Tomography (iRCM-CCT) is a multicenter, multivendor, observational study on the use of contrast media (CM) in patients undergoing cardiac computed tomography (CCT). The aim of iRCM-CCT is to assess image quality and safety profile of intravenous CM compounds. Materials and Methods: iRCM-CCT enrolled 1842 consecutive patients undergoing CCT (≥50 per site) at 20 cluster sites with the indication of suspected coronary artery disease. Demographic characteristics, CCT, and CM protocols, clinical indications, safety markers, radiation dose reports, qualitative (ie, poor vascular enhancement) and quantitative (ie, HU attenuation values) image parameters were recorded. A centralized coordinating center collected and assessed all image parameters. Results: The cohort included 891 men and 951 women (age: 63±14 y, body mass index: 26±4 kg/m2) studied with ≥64 detector rows computed tomography scanners and different iodinated intravenous CM protocols and compounds (iodixanol, iopamidol, iohexol, iobitridol, iopromide, and iomeprol). The following vascular attenuation was reported: 504±147 HU in the aorta, 451±146 HU in the right coronary artery, 474±146 HU in the left main, 451±146 HU in the left anterior descending artery, and 441±149 HU in the circumflex artery. In 4% of cases the image quality was not satisfactory due to poor enhancement. The following adverse reactions to CM were recorded: 6 (0.3%) extravasations and 17 (0.9%) reactions (11 mild, 4 moderate, 2 severe). Conclusions: In a multicenter registry on CM use during CCT the prevalence of CM-related adverse reactions was very low. The appropriate use of CM is a major determinant of image quality.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.