The paper presents the results of a comprehensive study on the evaluation of the effectiveness of a retrofit strategy of existing steel buildings against progressive collapse. In this respect, it investigates the performance and the design of a retrofit solution to increase the robustness of steel Moment Resisting Frame buildings. A truss steel system added at the building's rooftop level (i.e., 'roof-truss'), and intended to define an alternative load path, was investigated as a retrofit solution. The numerical model key components, including the plastic hinges and the beam-column connections, were validated against available experimental results. The validated models were then used to study the robustness of the structure under column loss scenarios by means of non-linear static and dynamic analyses performed in OpenSees. The simulations allowed for the identification of possible failure modes and alternative load paths together with the definition of the Dynamic Increase Factor (DIF). In this regard, it is shown that column buckling is critical for the selected case study. Moreover, the outcomes showed how the proposed retrofit solution allows the definition of effective alternative load paths when subjected to column loss scenarios and informs on the critical details that should be checked by employing this retrofit system.
Accidental events, such as impact loading or explosions, are rare events characterized by a very low probability of occurrence. However, their effects often lead to very high human losses and economic consequences as are likely to trigger the progressive collapse of the buildings. The progressive collapse of structures attracted the attention of many researchers and the topic has been widely investigated in recent years. In addition, increasing interest has been shown also on the definition of retrofit strategies able to increase the robustness of existing structures. The present work investigates the performance and the design of a retrofit solution to increase the robustness of steel moment resisting frames. A case study structure is selected and modelled in OpenSees, including both mechanical and geometrical non‐linearities. Non‐linear static analyses have been carried out on the frame, simulating a column loss scenario to investigate the subsequent load redistribution. The simulations showed that the case study was unable to redistribute the load and hence retrofitting was required. Among others, a truss system was added at the rooftop level of the building allowing the definition of an alternative load path. The analyses outcomes showed how the proposed retrofit method allows to increase the robustness of the case study structure and allowed for critical remarks on the checks required when this retrofit system is employed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.