This study aimed to determine the ultrasonographic features and reference values of the abdominal anatomy in mixed-breed dwarf rabbits. Complete abdominal ultrasonographic examination was performed in 21 mixed-breed rabbits (12 males and 9 females) referred for examination to the Department of Animal Medicine, Production and Health, University of Padua, Italy. All animals were sedated during the procedure. The ultrasonographic anatomy of the abdomen was determined, including measurement (mean±SD) of the right kidney (length 2.87±0.34 mm; width 1.62±0.17 mm; height 1.66±0.14 mm) and left kidney (length 2.86±0.33 mm; width 1.72±0.19; height 1.58±0.15 mm), left adrenal gland (width 0.38±0.11 mm; length 0.71±0.14), right adrenal gland (width 0.34±0.08 mm; length 0.73±0.15 mm) and thickness of the walls of the stomach (0.10±0.01 mm), pylorus (0.28±0.04 mm), duodenum (0.19±0.04 mm), sacculus rotundus (0.22±0.06 mm), caecum (0.08±0.01 mm), appendix (0.19±0.04 mm), spiral loop of the ascending colon (0.14±0.04 mm) and distal colon (0.10±0.02 mm). A significant positive correlation between bodyweight and kidney size, adrenal gland length, stomach wall and sacculus rotundus wall was detected.
BackgroundThe increasing popularity gained by pet birds over recent decades has highlighted the role of avian medicine and surgery in the global veterinary scenario; such a need for speciality avian medical practice reflects the rising expectation for high-standard diagnostic imaging procedures. The aim of this study is to provide an atlas of matched anatomical cross-sections and contrast-enhanced CT images of the coelomic cavity in three highly diffused psittacine species.ResultsContrast-enhanced computed tomographic studies of the coelomic cavity were performed in 5 blue-and-gold macaws, 4 African grey parrots and 6 monk parakeets by means of a 4-multidetector-row CT scanner. Both pre- and post-contrast scans were acquired. Anatomical reference cross-sections were obtained from 5 blue-and-gold macaw, 7 African grey parrot, and 9 monk parakeet cadavers. The specimens were stored in a −20 °C freezer until completely frozen and then sliced at 5-mm intervals by means of a band saw. All the slices were photographed on both sides. Individual anatomical structures were identified by means of the available literature. Pre- and post-contrast attenuation reference values for the main coelomic organs are reported in Hounsfield units (HU).ConclusionsThe results provide an atlas of matched anatomical cross-sections and contrast-enhanced CT images of the coelomic cavity in three highly diffused psittacine species.
The effects of two sedation protocols combining midazolam with ketamine (ketamine group) or dexmedetomidine (dexmedetomidine group) were studied in dwarf companion rabbits undergoing abdominal ultrasound scan. The onset of sedation was faster in the ketamine group; a few rabbits in the dexmedetomidine group required additional doses to lose the righting reflex, although sedation time was not different between groups. A semi-quantitative scale was used to score sedation quality, which was higher in rabbits that received dexmedetomidine rather than ketamine. Pulse rate was lower in the dexmedetomidine group (206 vs 240 bpm), although Doppler blood pressure was higher than in the ketamine group (109 vs 89 mm Hg). Respiratory rate decreased in relation to the baseline values with both protocols but arterial haemoglobin saturation with oxygen was maintained similar to the pre-sedation values throughout the entire procedure, regardless of protocol used and without oxygen supplementation. Both protocols allowed performance of ultrasound scanning, although dexmedetomidine may be preferred if a deep sedation level is required.
Echocardiographic evaluation was performed in six healthy young adult non-sedated terrapins (Trachemys scripta elegans). The best imaging quality was obtained through the right cervical window. Base-apex inflow and outflow views were recorded, ventricular size, ventricular wall thickness and ventricular outflow tract were measured, and fractional shortening was calculated. Pulsed-wave Doppler interrogation enabled the diastolic biphasic atrio-ventricular flow and the systolic ventricular outflow patterns to be recorded. The following Doppler-derived functional parameters were calculated: early diastolic (E) and late diastolic (A) wave peak velocities, E/A ratio, ventricular outflow systolic peak and mean velocities and gradients, Velocity-Time Integral, acceleration and deceleration times, and Ejection Time. For each parameter the mean, standard deviation and 95% confidence interval were calculated. Echocardiography resulted as a useful and easy-to-perform diagnostic tool in this poorly known species that presents difficulties during evaluation.
Objectives The aim of the study was to evaluate the end-tidal concentration of isoflurane required to maintain heart and respiratory rate within ± 20% of basal measurement in cats undergoing ovariectomy that received buprenorphine, tramadol or a combination of both. Methods Thirty cats, divided into three groups, were enrolled in a simple operator-blinded, randomised study. Cats received acepromazine (0.03 mg/kg) and one of the following treatments: buprenorphine (0.02 mg/kg), tramadol (2 mg/kg) or a combination of both. Anaesthesia was induced with propofol and maintained with isoflurane titrated in order to maintain heart and respiratory rate within the target values recorded before premedication. Results Groups were similar for age, weight, dose of propofol administered, sedation and recovery scores. Cats receiving tramadol with buprenorphine were extubated earlier after isoflurane discontinuation. No statistical differences were detected in end-tidal fraction of isoflurane between buprenorphine alone or with tramadol. In cats that received tramadol or buprenorphine alone, ovarian pedicle traction caused a statistical increase in end-tidal isoflurane concentration compared with that measured during incision and suture of the skin. In cats that received the combination of tramadol plus buprenorphine no differences among surgical time points were observed. Conclusions and relevance Tramadol added to buprenorphine did not provide any advantage in decreasing the end-tidal fraction of isoflurane compared with buprenorphine alone, although it is speculated there may be an infra-additive interaction between tramadol and buprenorphine in cats.
OBJECTIVE To create an atlas of the normal CT anatomy of the head of blue-and-gold macaws (Ara ararauna), African grey parrots (Psittacus erithacus), and monk parakeets (Myiopsitta monachus). ANIMALS 3 blue-and-gold macaws, 5 African grey parrots, and 6 monk parakeets and cadavers of 4 adult blue-and-gold macaws, 4 adult African grey parrots, and 7 monk parakeets. PROCEDURES Contrast-enhanced CT imaging of the head of the live birds was performed with a 4-multidetector-row CT scanner. Cadaveric specimens were stored at -20°C until completely frozen, and each head was then sliced at 5-mm intervals to create reference cross sections. Frozen cross sections were cleaned with water and photographed on both sides. Anatomic structures within each head were identified with the aid of the available literature, labeled first on anatomic photographs, and then matched to and labeled on corresponding CT images. The best CT reconstruction filter, window width, and window level for obtaining diagnostic images of each structure were also identified. RESULTS Most of the clinically relevant structures of the head were identified in both the cross-sectional photographs and corresponding CT images. Optimal visibility of the bony structures was achieved via CT with a standard soft tissue filter and pulmonary window. The use of contrast medium allowed a thorough evaluation of the soft tissues. CONCLUSIONS AND CLINICAL RELEVANCE The labeled CT images and photographs of anatomic structures of the heads of common pet parrot species created in this study may be useful as an atlas to aid interpretation of images obtained with any imaging modality.
BackgroundRabbits are particularly sensitive to develop hypotension during sedation or anaesthesia. Values of systolic or mean non-invasive arterial blood pressure below 80 or 60 mmHg respectively are common under anaesthesia despite an ongoing surgery. A reliable method of monitoring arterial blood pressure is extremely important, although invasive technique is not always possible due to the anatomy and dimension of the artery. The aim of this study was to evaluate the agreement between a new oscillometric device for non-invasive arterial blood pressure measurement and the invasive method. Moreover the trending ability of the device, ability to identify changes in the same direction with the invasive methods, was evaluated as well as the sensibility of the device in identifying hypotension arbitrarily defined as invasive arterial blood pressure below 80 or 60 mmHg.ResultsBland-Altman analysis for repeated measurements showed a poor agreement between the two methods; the oscillometric device overestimated the invasive arterial blood pressure, particularly at high arterial pressure values. The same analysis repeated considering oscillometric measurement that match invasive mean pressure lower or equal to 60 mmHg showed a decrease in biases and limits of agreement between methods. The trending ability of the device, evaluated with both the 4-quadrant plot and the polar plot was poor. Concordance rate of mean arterial blood pressure was higher than systolic and diastolic pressure although inferior to 90%. The sensibility of the device in detecting hypotension defined as systolic or mean invasive arterial blood pressure lower than 80 or 60 mmHg was superior for mean oscillometric pressure rather than systolic. A sensitivity of 92% was achieved with an oscillometric measurement for mean pressure below 65 mmHg instead of 60 mmHg. Non-invasive systolic blood pressure is less sensitive as indicator of hypotension regardless of the cutoff limit considered.ConclusionsAlthough mean invasive arterial blood pressure is overestimated by the device, the sensitivity of this non-invasive oscillometric monitor in detecting invasive mean pressure below 60 mmHg is acceptable but a cutoff value of 65 mmHg needs to be used.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.