In this study nitrogen removal via nitrite >80% was achieved after approximately 80days in a sequencing batch reactor (SBR) treating pre-treated industrial wastewater originating from the potato industry. Thereafter, SBR performance was investigated during the formation of aerobic nitrite granules (ANG). The first granules appeared after 26days leading to full granulation after 64days. ANG showed excellent settling properties, as the Sludge Volume Index (SVI) went down to 16mL/g and a SVI/SVI=1 was obtained. qPCR analysis showed that slow growing organisms, especially polyphosphate accumulating organisms (PAO) were stimulated by an anaerobic feeding strategy. The average nitrogen removal was 95.3% over the entire operational period, and it mainly followed the "nitrite-route". Moreover, with ANG also phosphorus removal efficiencies up to 65.7% could be achieved. However, it has to be mentioned that nitrous oxide was an important denitrification product, which implies some environmental concerns.
In this study, petrochemical wastewater from the port of Antwerp was used for the development of aerobic granular sludge. Two different reactor setups were used, (1) a completely aerated sequencing batch reactor (SBR) with a feast/famine regime and (2) a sequencing batch reactor operated with an anaerobic feast/aerobic famine strategy (SBR). The seed sludge showed poor settling characteristics with a sludge volume index (SVI) of 285mL.gMLSS and a median particle size by volume of 86.0µm±1.9µm. In both reactors, granulation was reached after 30days with a SVI of 71mL.gMLSS and median granule size of 264.7µm in SBR and a SVI of 56mL.gMLSS and median granule size of 307.4µm in SBR. The chemical oxygen demand (COD) and dissolved organic carbon (DOC) removal was similar in both reactors and above 95%. The anaerobic DOC uptake increased from 0.13% to 43.2% in 60days in SBR.
The present study compares conventional wastewater treatment technologies (coagulation-flocculation and activated sludge) and powdered activated carbon (PAC) treatment for the removal of acute ecotoxicity from wastewater generated by tank truck cleaning (TTC) processes. Ecotoxicity was assessed with a battery of four commercially available rapid biological toxicity testing systems, verified by the US Environmental Protection Agency. Chemical coagulation-flocculation of raw TTC wastewater had no impact on the inhibition of the bioluminescence by Vibrio fischeri (BioTox assay). Subsequent biological treatment with activated sludge without PAC resulted in BioTox inhibition-free effluent (<10% inhibition). In contrast, activated sludge treatment without PAC produced an effluent that significantly inhibited (>50%) (i) the bioluminescence by Photobacterium leiognathi (ToxScreen³ test kit), (ii) the photosynthesis by the green algae Chlorella vulgaris (LuminoTox SAPS test kit), and (iii) the particle ingestion by the crustacean Thamnocephalus platyurus (Rapidtoxkit test kit). The lowest inhibition was measured after activated sludge treatment with the highest PAC dose (400 mg/L), demonstrating the effectiveness of PAC treatment for ecotoxicity removal from TTC wastewater. In conclusion, the combination of bioassays applied in the present study represents a promising test battery for rapid ecotoxicty assessment in wastewater treatment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.