The FRANCE TAVI registry provided reassuring data regarding trends in TAVR performance in an all-comers population on a national scale. Nonetheless, given that TAVR indications are likely to expand to patients at lower surgical risk, concerns remain regarding potentially life-threatening complications and pacemaker implantation. (Registry of Aortic Valve Bioprostheses Established by Catheter [FRANCE TAVI]; NCT01777828).
Complete atrioventricular block (AVB) following radiotherapy has been reported rarely, usually after high dose mediastinal irradiation for Hodgkin's disease or lung or breast carcinoma. We report six new cases of episodic complete infranodal AVB, requiring permanent pacemaker implantation. The mean age was 48-years old (ranging from 25-60) at the first Adams Stokes attack, mean delay was 12 years after irradiation (10-18), and mean radiation dose was 5,200 rads (4,000-6,500). All patients had abnormal interval electrocardiograms (right bundle branch block in two, left bundle branch block in three, alternating left and right bundle branch block in one). Electrocardiograms during the episode of AVB or Holter recordings were consistent with infranodal block in all patients; electrophysiological study performed in five patients confirmed infranodal AVB in four, and one was normal. Pericardial disease was constant, which included pericardial constriction in four patients. Two patients died after failure of pericardiectomy to improve congestive heart failure, due to epicardial, myocardial, and endocardial involvement. Noncardiac mediastinal lesions were present in four cases. Since this delayed complication may occur in patients of such age that the relation between the AVB and the chest irradiation is questionable, we propose the following etiologic criteria; high radiation dose (over 4,000 rads); delay of 10 years or more; abnormal interval tracings; pericardial involvement; and associated cardiac or mediastinal radiation-induced lesions.
Urinary clearance of antidiuretic hormone (ADH) has been measured under basal conditions and during intravenous administration of arginine vasopressin in ten healthy subjects, and only under basal conditions in 18 patients with chronic renal failure and seven patients with acute renal failure at the polyuric phase of the disease. In healthy subjects studied under conditions of mild water diuresis plasma concentration, urinary excretion rate, urinary clearance and fractional clearance of ADH were 3.3 +/- 0.36 pg/ml, 25.2 +/- 5.5 pg/min, 7.5 +/- 1.2 ml/min and 6.4 +/- 1.0% (means +/- SEM) respectively. When plasma ADH was raised to levels between 7 and 26 pg/ml during intravenous administration of the hormone, urinary excretion rate and urinary clearance of ADH increased. Tubular reabsorption of ADH did not reach a plateau but progressively increased in the range of plasma ADH studied. In patients with chronic renal failure, plasma concentration, urinary excretion rate, urinary clearance and fractional clearance of ADH were 2.8 +/- 0.19 pg/ml, 9.4 +/- 2.0 pg/min, 3.4 +/- 0.6 ml/min and 10.0 +/- 2.9% (means +/- SEM) respectively. Urinary excretion rate and urinary clearance were significantly lower than in healthy subjects. In patients with acute renal failure, plasma concentration, urinary excretion rate, urinary clearance and fractional clearance of ADH were 4.6 +/- 0.47 pg/ml, 52.8 +/- 15.8 pg/min, 9.5 +/- 2.7 ml/min and 24.9 +/- 4.4% (means +/- SEM) respectively. Urinary excretion rate and fractional clearance were higher than in healthy subjects and patients with chronic renal failure.(ABSTRACT TRUNCATED AT 250 WORDS)
The feasibility and results of percutaneous double balloon valvuloplasty were evaluated in 2 patients with stenosis of porcine bioprostheses in the tricuspid valve position. The procedures were performed with a Trefoil 3 x 10 and a 15 mm balloon. Long inflations (4 and 3 minutes) were well tolerated. A significant immediate increase in the valve area, without significant valvular regurgitation, was achieved in both cases, from 0.65 to 1.15 cm2 in case 1 and from 0.9 to 1.65 cm2 in case 2. Both patients required valve replacement during the follow-up, at 14 and 21 months. There was no restenosis, but echocardiography showed right atrial thrombosis in case 1. Progressive restenosis with peripheral edema and increase of the mean doppler gradient occurred in case 2. The procedure is feasible, safe, and well tolerated. It provides significant immediate hemodynamic improvement, but it should be considered as a palliative technique since a normal valve area can not usually be obtained and a restenosis is likely to occur at midterm follow-up.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.