ABSTRACT. Newborns are predisposed to neutropenia and thrombocytopenia during bacterial sepsis. The presence of peripheral cytopenias during overwhelming infec-
Neonates, especially those of very low birthweight (VLBW), have an increased risk of nosocomial infections secondary to deficiencies in development. We previously demonstrated that granulocyte-macrophage colony-stimulating factor (GM-CSF) production and mRNA expression from stimulated neonatal mononuclear cells are significantly less than that from adult cells. Recombinant murine GM-CSF administration to neonatal rats has resulted in neutrophilia, increased neutrophil production, and increased survival of pups during experimental Staphylococcus aureus sepsis. In the present study, we sought to determine the safety and biologic response of recombinant human (rhu) GM-CSF in VLBW neonates. Twenty VLBW neonates (500 to 1,500 g), aged < 72 hours, were randomized to receive either placebo (n = 5) or rhuGM-CSF at 5.0 micrograms/kg once per day (n = 5), 5.0 micrograms/kg twice per day (n = 5), or 10 micrograms/kg once per day (n = 5) given via 2-hour intravenous infusion for 7 days. Complete blood counts, differential, and platelet counts were obtained, and tibial bone marrow aspirate was performed on day 8. Neutrophil C3bi receptor expression was measured at 0 and 24 hours. GM-CSF levels were measured by a sandwich enzyme-linked immunosorbent assay at 2, 4, 6, 12, and 24 hours after the first dose of rhuGM-CSF. At all doses, rhuGM-CSF was well tolerated, and there was no evidence of grade III or IV toxicity. Within 48 hours of administration, there was a significant increase in the circulating absolute neutrophil count (ANC) at 5.0 micrograms/kg twice per day and 10.0 micrograms/kg once per day, which continued for at least 24 hours after discontinuation of rhuGM-CSF. When the ANC was normalized for each patient's first ANC, there was a significant increase in the ANC on days 6 and 7 at each dose level. By day 7, all tested doses of rhuGM- CSF resulted in an increase in the absolute monocyte count (AMC) compared with placebo-treated neonates. In those receiving rhuGM-CSF 5.0 micrograms/kg twice per day, there was additionally a significant increase in the day 7 and 8 platelet count. Tibial bone marrow aspirates demonstrated a significant increase in the bone marrow neutrophil storage pool (BM NSP) at 5.0 micrograms/kg twice per day and 10.0 micrograms/kg once per day. Neutrophil C3bi receptor expression was significantly increased 24 hours after the first dose of rhuGM-CSF at 5.0 micrograms/kg once per day. The elimination half-life (T1/2) of rhuGM-CSF was 1.4 +/- 0.8 to 3.9 +/- 2.8 hours.(ABSTRACT TRUNCATED AT 400 WORDS)
Myeloid engraftment after bone marrow transplantation (BMT) is influenced by a number of variables, including cytoreductive chemoradiotherapy, genetic disparity, number of reinfused committed myeloid progenitor cells, healthy microenvironment, and the presence of hematopoietic growth factors. Granulocyte colony-stimulating factor (G- CSF) stimulates proliferation of myeloid progenitor cells and enhances myeloid engraftment after BMT. We investigated the temporal relationship between endogenous G-CSF production and myeloid engraftment in both children and adults after allogeneic (ALLO) and autologous (AUTO) BMT. Circulating endogenous G-CSF levels ranged between 0 and 2552 pg/mL. The correlation coefficient between circulating serum G-CSF levels and the peripheral absolute neutrophil count (ANC) was r = -.875 (P less than .001). The endogenous serum G- CSF level was highest during the first week after BMT, when the ANC was less than or equal to 200/microL (699 +/- 82.3 pg/mL) (P less than .001). Both children and adults demonstrated a similar inverse relationship between circulating G-CSF level and degree of neutropenia. One patient failed to engraft after AUTO BMT and also failed to generate any endogenous G-CSF production. Lastly, once the serum G-CSF level decreased to less than 200 pg/mL, a mean of 6.1 +/- 0.9 days elapsed before the ANC was greater than or equal to 500/microL for 2 consecutive days. This study demonstrates that endogenous G-CSF production is associated with myeloid engraftment in both children and adults after AUTO and ALLO BMT and that the rate of increase and decrease in endogenous G-CSF may be predictive of either failure to engraft or duration of neutropenia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.