BackgroundQuantitative single photon emission computed tomography (SPECT) is challenging, especially for pancreatic beta cell imaging with 111In-exendin due to high uptake in the kidneys versus much lower uptake in the nearby pancreas. Therefore, we designed a three-dimensionally (3D) printed phantom representing the pancreas and kidneys to mimic the human situation in beta cell imaging. The phantom was used to assess the effect of different reconstruction settings on the quantification of the pancreas uptake for two different, commercially available software packages.Methods3D-printed, hollow pancreas and kidney compartments were inserted into the National Electrical Manufacturers Association (NEMA) NU2 image quality phantom casing. These organs and the background compartment were filled with activities simulating relatively high and low pancreatic 111In-exendin uptake for, respectively, healthy humans and type 1 diabetes patients. Images were reconstructed using Siemens Flash 3D and Hermes Hybrid Recon, with varying numbers of iterations and subsets and corrections. Images were visually assessed on homogeneity and artefacts, and quantitatively by the pancreas-to-kidney activity concentration ratio.ResultsPhantom images were similar to clinical images and showed comparable artefacts. All corrections were required to clearly visualize the pancreas. Increased numbers of subsets and iterations improved the quantitative performance but decreased homogeneity both in the pancreas and the background. Based on the phantom analyses, the Hybrid Recon reconstruction with 6 iterations and 16 subsets was found to be most suitable for clinical use.ConclusionsThis work strongly contributed to quantification of pancreatic 111In-exendin uptake. It showed how clinical images of 111In-exendin can be interpreted and enabled selection of the most appropriate protocol for clinical use.
Development of trunk and head supportive devices for children with neuromuscular disorders requires detailed information about pelvis, trunk and head movement in interaction with upper extremity movement, as these are crucial for daily activities when seated in a wheelchair. Twenty-five healthy subjects (6–20 years old) were included to obtain insight in the physiological interactions between these segments and to assess maturation effects. Subjects performed a maximum range of trunk and head movement tasks and several daily tasks, including forward and lateral reaching. Movements of the arms, head, pelvis, and sub-sections of the trunk were recorded with an optical motion capture system. The range of motion of each segment was calculated. Contributions of individual trunk segments to the range of trunk motion varied with movement direction and therefore with the task performed. Movement of pelvis and all trunk segments in the sagittal plane increased significantly with reaching height, distance and object weight when reaching forward and lateral. Trunk movement in reaching decreased with age. Head movement was opposite to trunk movement in the sagittal (> 50% of the subjects) and transverse planes (> 75% of the subjects) and was variable in the frontal plane in most tasks. Both trunk and head movement onsets were earlier compared to arm movement onset. These results provide insight in the role of the upper body in arm tasks in young subjects and can be used for the design of trunk and head supportive devices for children with neuromuscular disorders.
A feasibility study was performed to evaluate the control interfaces for a novel trunk support assistive device (Trunk Drive), namely, joystick, force on sternum, force on feet, and electromyography (EMG) to be used by adult men with Duchene muscular dystrophy. The objective of this paper was to evaluate the performance of the different control interfaces during a discrete position tracking task. We built a one degree of freedom flexion-extension active trunk support device that was tested on 10 healthy men. An experiment, based on the Fitts law, was conducted, whereby subjects were asked to steer a cursor representing the angle of the Trunk Drive into a target that was shown on a graphical user interface, using the above-mentioned control interfaces. The users could operate the Trunk Drive via each of the control interfaces. In general, the joystick and force on sternum were the fastest in movement time (more than 40%) without any significant difference between them, but there was a significant difference between force on sternum on the one hand, and EMG and force on feet on the other. All control interfaces proved to be feasible solutions for controlling an active trunk support, each of which had specific advantages.
BackgroundPatients with Duchenne muscular dystrophy gradually lose the ability to use different muscles of their body. Consequently, they lose the ability to stabilize their trunk against gravity. This hinders them to effectively perform different daily activities. In this paper, we describe the design, realization and evaluation of a trunk orthosis for these patients that should allow them to move their trunk and maintain stability.MethodThis study aimed to primarily assess the effectiveness of the trunk support system in terms of unloading of trunk muscles, so only healthy participants were recruited for this phase of the study. Measurements were done on 10 healthy participants (23.4±2.07 [M±SD] years old, average body weight 68.42±24.22 [M±SD] kg). The experiment comprised maintaining a constant trunk posture in three different device conditions (control without orthosis and two conditions with different configurations of the orthosis), at four different flexion angles (10°, 20°, 30°, 40°) for each device condition and for two load conditions (with and without stretching the arms). Electromyography (EMG) signals from the trunk muscles were measured to estimate activation levels of the trunk muscles (iliocostalis, longissimus, external oblique and rectus abdominis) and a motion capture system was used to record the movement of the participants during the experiment.ResultsWearing the orthosis caused reductions in longissimus and iliocostalis activity. The average muscle activity level was 5%–10% of maximum voluntary contraction in the unsupported conditions for those particular muscles. This level was reduced to 3%–9% of maximal voluntary contraction for the supported conditions. No effect on external oblique and rectus abdominis activity was observed. Moreover, no pain or discomfort was reported by any of the participants during the experiment. The results from the current experiment also suggests the necessity of lumber stabilizing systems while using trunk orthosis.ConclusionThe developed orthosis reduces trunk muscle activation level and provides a solid step for further development of support systems for Duchenne muscular dystrophy patients.Trial registrationThe current study was approved by the medical ethics committee Arnhem-Nijmegen (study number: NL53143.091.15), The Netherlands.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.