Cryptococcus neoformans can cause disseminated meningoencephalitis and evade immunosurveillance with expression of a major virulence factor, the polysaccharide capsule. Direct diagnostic assays often rely on the presence of the cryptococcal glucuronoxylomannan capsular antigen (CrAg) or visualization of the capsule. Strain specific phenotypic traits and environmental conditions influence differences in expression that can thereby compromise detection and timely diagnosis. Immunocompetent hosts may manifest clinical signs and symptoms indolently, often expanding the differential and delaying appropriate treatment and diagnosis. We describe a 63-year-old man who presented with a progressive four-year history of ambulatory dysfunction, headache, and communicating hydrocephalus. Serial lumbar punctures (LPs) revealed elevated protein (153–300 mg/dL), hypoglycorrhachia (19–47 mg/dL), lymphocytic pleocytosis (89–95% lymphocyte, WBC 67–303 mg/dL, and RBC 34–108 mg/dL), and normal opening pressure (13–16 cm H2O). Two different cerebrospinal fluid (CSF) CrAg assays were negative. A large volume CSF fungal culture grew unencapsulated C. neoformans. He was initiated on induction therapy with amphotericin B plus flucytosine and consolidation/maintenance therapy with flucytosine, but he died following discharge due to complications. Elevated levels of CSF Th1 cytokines and decreased IL6 may have affected the virulence and detection of the pathogen.
Background
Single-use flexible bronchoscopes eliminate cross contamination from reusable bronchoscopes and are cost-effective in a number of clinical settings. The present bench study aimed to compare the performance of a new single-use bronchoscope (Boston Scientific EXALT Model B) to a marketed single-use comparator (Ambu aScope 4), each in slim, regular and large diameters.
Methods
Three bronchoscopy tasks were performed: water suction and visualization, “mucus” mass (synthetic mucoid mixture) suctioned in 30 s, and “mucus” plug (thicker mucoid mixture) suction. Suction ability, task completion times, and subjective ratings of visualization and overall performance on a scale of one to 10 (best) were compared. All bronchoscopy tasks were completed by 15 physicians representing diversity in specialization including pulmonary, interventional pulmonary, critical care, anesthesia, and thoracic surgery. Each physician utilized the six bronchoscope versions with block randomization by bronchoscope and task.
Results
Aspirated mean mass of “mucus” using EXALT Model B Regular was comparable to that for an aScope 4 Large (41.8 ± 8.3 g vs. 41.5 ± 5.7 g respectively, p = 0.914). In comparisons of scopes with the same outer diameter, the aspirated mean mass by weight of water and “mucus” was significantly greater for EXALT Model B than for aScope 4 (p < 0.001 for all three diameters). Mean ratings for visualization attributes were significantly better for EXALT Model B compared to aScope 4 (p-value range 0.001−0.029).
Conclusion
A new single-use bronchoscope provided strong suction capability and visualization compared to same-diameter marketed single-use comparators in a bench model simulation.
Preserved cardiac specimen demonstrating thrombus layering inside the left ventricle.
Central MessageConsider and explore multiple treatment options for complex, advanced cardiovascular disease.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.