Background Hearing impairment is the most frequent sensory deficit in humans, affecting more than 360 million people worldwide. In fact, hearing impairment is not merely a health problem, but it also has a great impact on the educational performance, economic income, and quality of life. Hearing impairment is therefore an important social concern. Objective We aimed to evaluate and compare the accuracy of self-perception, Hearing Handicap Inventory for the Elderly-Screening (HHIE-S) questionnaire, free-field voice test, and smartphone-based audiometry as tests for screening moderate hearing impairment in older adults in China. Methods In this study, 41 patients were recruited through a single otology practice. All patients were older than 65 years. Patients with otorrhea and cognitive impairment were excluded. Moderate hearing impairment was defined as mean hearing thresholds at 500, 1000, 2000, and 4000 Hz >40 dB hearing loss (pure-tone average > 40 dB hearing loss). All patients completed 5 hearing tests, namely, the self-perception test, HHIE-S questionnaire test, free-field voice test, smartphone-based audiometry test, and standard pure-tone audiometry by the same audiologist. We compared the results of these tests to the standard audiogram in the better-hearing ear. Results The sensitivity and the specificity of the self-perception test were 0.58 (95% CI 0.29-0.84) and 0.34 (95% CI 0.19-0.54), respectively. The sensitivity and the specificity of the HHIE-S questionnaire test were 0.67 (95% CI 0.35-0.89) and 0.31 (95% CI 0.316-0.51), respectively. The sensitivity and the specificity of the free-field voice test were 0.83 (95% CI 0.51-0.97) and 0.41 (95% CI 0.24-0.61), respectively. The sensitivity and the specificity of the smartphone-based audiometry test were 0.92 (95% CI 0.60-0.99) and 0.76 (95% CI 0.56-0.89), respectively. Smartphone-based audiometry correctly diagnosed the presence of hearing loss with high sensitivity and high specificity. Conclusions Smartphone-based audiometry may be a dependable screening test to rule out moderate hearing impairment in the older population.
Hearing impairment is a frequent human sensory impairment. It was estimated that over 50% of those aged >75 years experience hearing impairment in the United States. Several hearing impairment–related factors are detectable through screening; thus, further deterioration can be avoided. Early identification of hearing impairment is the key to effective management. However, hearing screening resources are scarce or inaccessible, underlining the importance of developing user-friendly mobile health care systems for universal hearing screening. Mobile health (mHealth) applications (apps) act as platforms for personalized hearing screening to evaluate an individual’s risk of developing hearing impairment. We aimed to evaluate and compare the accuracy of smartphone-based air conduction and bone conduction audiometry self-tests with that of standard air conduction and bone conduction pure-tone audiometry tests. Moreover, we evaluated the use of smartphone-based air conduction and bone conduction audiometry self-tests in conductive hearing loss diagnosis. We recruited 103 patients (206 ears) from an otology clinic. All patients were aged ≥20 years. Patients who were diagnosed with active otorrhea was excluded. Moderate hearing impairment was defined as hearing loss with mean hearing thresholds >40 dB. All patients underwent four hearing tests performed by a board-certified audiologist: a smartphone-based air conduction audiometry self-test, smartphone-based bone conduction audiometry self-test, standard air-conduction pure-tone audiometry, and standard bone conduction pure-tone audiometry. We compared and analyzed the results of the smartphone-based air conduction and bone conduction audiometry self-tests with those of the standard air conduction and bone conduction pure-tone audiometry tests. The sensitivity of the smartphone-based air conduction audiometry self-test was 0.80 (95% confidence interval CI = 0.71–0.88) and its specificity was 0.84 (95% CI = 0.76–0.90), respectively. The sensitivity of the smartphone-based bone conduction audiometry self-test was 0.64 (95% CI = 0.53–0.75) and its specificity was 0.71 (95% CI = 0.62–0.78). Among all the ears, 24 were diagnosed with conductive hearing loss. The smartphone-based audiometry self-tests correctly diagnosed conductive hearing loss in 17 of those ears. The personalized smartphone-based audiometry self-tests correctly diagnosed hearing loss with high sensitivity and high specificity, and they can be a reliable screening test to rule out moderate hearing impairment among the population. It provided patients with moderate hearing impairment with personalized strategies for symptomatic control and facilitated individual case management for medical practitioners.
As part of the new measures to prevent the spread of the 2019 coronavirus disease (COVID-19), medical students were advised to wear a mask in class and avoid touching their faces. Few studies have analyzed the influence of health education on the frequency of face- and smartphone-touching behaviors during the COVID-19 pandemic. This research compared the frequency of in-class face- and smartphone-touching behaviors of medical students before and after the delivery of personal hygiene education during the COVID-19 pandemic. A behavioral observational study was conducted involving medical students at Taipei Medical University. Eighty medical students were recruited during a lecture on otorhinolaryngology. All medical students were required to wear a mask. Their face- and smartphone-touching behavior was observed by viewing the 4k resolution video tape recorded in class. The recording lasted for 2 h, comprising 1 h prior to the health educational reminder and 1 h afterwards. The frequencies of hand-to-face contact and hand-to-smartphone contact were analyzed before and after the delivery of health education emphasizing personal hygiene. Comprehensive health education and reminders effectively reduce the rate of face- and smartphone-touching behaviors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.