Background Hereditary motor and sensory neuropathies (HMSN), also known as Charcot-Marie-Tooth disease, are characterized by affected peripheral nerves. This often results in foot deformities that can be classified into four categories: (1) plantar flexed first metatarsal, neutral hindfoot, (2) plantar flexed first metatarsal, correctable hindfoot varus, (3) plantar flexed first metatarsal, uncorrectable hindfoot varus, and (4) hindfoot valgus. To improve management and for the evaluation of surgical interventions, a quantitative evaluation of foot function is required. The first aim of this study was to provide insight into plantar pressure of people with HMSN in relation to foot deformities. The second aim was to propose a quantitative outcome measure for the evaluation of surgical interventions based on plantar pressure. Methods In this historic cohort study, plantar pressure measurements of 52 people with HMSN and 586 healthy controls were evaluated. In addition to the evaluation of complete plantar pressure patterns, root mean square deviations (RMSD) of plantar pressure patterns from the mean plantar pressure pattern of healthy controls were calculated as a measure of abnormality. Furthermore, center of pressure trajectories were calculated to investigate temporal characteristics. Additionally, plantar pressure ratios of the lateral foot, toes, first metatarsal head, second/third metatarsal heads, fifth metatarsal head, and midfoot were calculated to measure overloading of foot areas. Results Larger RMSD values were found for all foot deformity categories compared to healthy controls (p < 0.001). Evaluation of the complete plantar pressure patterns revealed differences in plantar pressure between people with HMSN and healthy controls underneath the rearfoot, lateral foot, and second/third metatarsal heads. Center of pressure trajectories differed between people with HMSN and healthy controls in the medio-lateral and anterior-posterior direction. The plantar pressure ratios, and especially the fifth metatarsal head pressure ratio, differed between healthy controls and people with HMSN (p < 0.05) and between the four foot deformity categories (p < 0.05). Conclusions Spatially and temporally distinct plantar pressure patterns were found for the four foot deformity categories in people with HMSN. We suggest to consider the RMSD in combination with the fifth metatarsal head pressure ratio as outcome measures for the evaluation of surgical interventions in people with HMSN.
Background: Due to anatomical deviations, assumptions of the conventional calibration method for gait analysis may be violated in individuals with rotational deformities of the femur. We compared functional calibration methods with conventional methods in this group for 1) localization of the hip joint center (HJC) and knee axis orientation, and 2) gait kinematics. Methods: Twenty-four adolescents with idiopathic rotational deformity of the femur underwent gait analysis and a CT scan. During standing, distance between HJCs and knee axis orientation were compared between calibration methods, with CT serving as reference for HJC estimation. Gait kinematics were compared using statistical parameter mapping (SPM). Findings: Functional calibration methods estimated the HJC closer to the CT reference (26±21mm more lateral) than the conventional method (38±21mm more medial). In the full sample, orientation of the knee joint axis was not different between calibration methods, but in adolescents with increased femoral anteversion, the knee was more internally rotated with the functional method (3.3±6.2°). During gait, SPM revealed significantly more hip flexion, more internal hip rotation during the stance phase, less knee varus-valgus motion, and larger knee flexion angles when applying the functional calibration method. Interpretation: Functional calibration methods better approximated the HJC, and showed a knee axis orientation that was more towards the direction of the deformity. This resulted in less knee joint angle crosstalk during gait. Although differences between calibration methods on gait kinematics were within clinically acceptable limits for the sagittal plane, relatively larger differences on transversal hip kinematics may hold clinical importance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.