Background Wearable cardioverter defibrillator (WCD) therapy is feasible and safe in patients as a transient protection against sudden cardiac death (SCD). However, the impact of WCD therapy on quality of life (QoL) has not been studied. Methods In our single-centre study, 109 consecutive patients with a prescription of WCD were retrospectively analysed. Quality of life has been assessed by a standardized questionnaire (EQ-5D-3L, modified). Additionally, clinical baseline and follow-up data and recorded arrhythmic episodes were evaluated. Results Mean WCD therapy time was 56.2 (± 42.4) days, with a daily wear time of 19.7 (± 5) hours. A total of 3441 arrhythmia episodes were detected. Of these, 27 (1%) were adequate but did not require shock therapy. Likewise, no inadequate shock therapy occurred. WCD therapy negatively affected quality of life: 43% of patients reported mental health issues. 37% reported pain or discomfort. Self-care, usual activities, and mobility were restricted in 17%, 48%, and 36%, respectively. 29% were afraid of receiving shock therapy, and 48% suffered from sleep disturbance. However, 64% indicated having felt safe during WCD therapy. Accordingly, average quality of life was rated 70/100 points. Conclusion In our cohort, no SCD was prevented by WCD therapy. In contrast, in this preliminary study quality of life was reduced. Thus, careful recommendation of WCD therapy for high risk patients should be considered.
Aims
Pulmonary vein isolation (PVI) either by balloon devices or radiofrequency forms the cornerstone of invasive atrial fibrillation (AF) treatment. Although equally effective cryoballoon (CB)-based PVI offers shorter procedure duration and a better safety profile. Beside the worldwide established Arctic Front Advance system, a novel CB device, POLARx, was recently introduced. This CB incorporates unique features, which may translate into improved efficacy and safety. However, multicentre assessment of periprocedural efficacy and safety is lacking up to date.
Methods and results
A total of 317 patients with paroxysmal or persistent AF were included and underwent POLARx CB-based PVI in 6 centres from Germany and Italy. Acute efficacy and safety were assessed in this prospective multicenter observational study. In 317 patients [mean age: 64 ± 12 years, 209 of 317 (66%) paroxysmal AF], a total of 1256 pulmonary veins (PVs) were identified and 1252 (99,7%) PVs were successfully isolated utilizing mainly the short tip POLARx CB (82%). The mean minimal CB temperature was −57.9 ± 7°C. Real-time PVI was registered in 72% of PVs. The rate of serious adverse events was 6.0% which was significantly reduced after a learning curve of 25 cases (9.3% vs. 3.0%, P = 0.018). The rate of recurrence-free survival after mean follow-up of 226 ± 115 days including a 90-day blanking period was 86.1%.
Conclusion
In this large multicentre assessment, the novel POLARx CB shows a promising efficacy and safety profile after a short learning curve.
Interrogation of CIED revealed potentially lethal ventricular arrhythmias in 9 of 70 patients investigated and enabled valid estimation of the day of death in 15 patients. We therefore conclude that routinely performed postmortem CIED interrogation may clarify time and cause of death.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.