Background
We describe a successful interdisciplinary liaison program that effectively reduced health care-acquired (HCA), methicillin-resistant Staphylococcus aureus (MRSA) in a university hospital setting.
Methods
Baseline was from January 2006 to March 2008, and intervention period was April 2008 to September 2009. Staff nurses were trained to be liaisons (link nurses) to infection prevention (IP) personnel with clearly defined goals assigned and with ongoing monthly education. HCA-MRSA incidence per 1,000 patient-days (PD) was compared between baseline and intervention period along with total and non-HCA-MRSA, HCA and non-HCA-MRSA bacteremia, and hand soap/sanitizer usage. Hand hygiene compliance was assessed.
Results
A reduction in MRSA rates was as follows in intervention period compared with baseline: HCA-MRSA decreased by 28% from 0.92 to 0.67 cases per 1,000 PD (incidence rate ratio, 0.72; 95% confidence interval: 0.62–0.83, P < .001), and HCA-MRSA bacteremia rate was reduced by 41% from 0.18 to 0.10 per 1,000 PD (incidence rate ratio, 0.59; 95% confidence interval: 0.42–0.84, P = .003). Total MRSA rate and MRSA bacteremia rate also showed significant reduction with nonsignificant reductions in overall non-HCA-MRSA and non-HCA-MRSA bacteremia. Hand soap/sanitizer usage and compliance with hand hygiene also increased significantly during IP.
Conclusion
Link nurse program effectively reduced HCA-MRSA. Goal-defined metrics with ongoing reeducation for the nurses by IP personnel helped drive these results.
Infection as a complication of long-term left ventricular assist device (LVAD) support leads to significant morbidity and mortality. Obesity, a possible risk factor for other postoperative cardiovascular surgical site infections, is an increasingly prevalent condition among recipients of LVAD devices. We retrospectively analyzed 145 LVADs that remained in place beyond 30 days over a nine-year period at a single medical institution. Statistical analysis was carried out using univariate and multivariable logistic regression and chi(2)-testing where indicated. Body mass index (BMI) had no effect on the incidence of infectious outcomes regardless of age, gender, underlying pathogen or device type. This included the morbidly obese population as well (BMI >or=40). Independent of BMI, device type did have an effect, with the HeartMate XVE increasing the risk for infections [odds ratio (OR) 4.3 with 95% confidence interval (CI) 2.1-8.8, P=0.0001] and the HeartMate II reducing the risk (OR 0.21 with 95% CI 0.09-0.50, P=0.0001). The risk for infection after LVAD placement for long-term support is likely to be a multi-factorial phenomenon. BMI, including morbid obesity, does not appear to be a statistically significant relevant factor in determining that risk. Device type may have an effect, however, on risk of infection in long-term support.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.