Objectives To evaluate the usefulness of a negative D-dimer in peripheral or central venous blood to screen for asymptomatic catheter-related thrombosis in cancer patients. Methods D-dimer was measured in blood from central venous catheter and peripheral venous samples in 48 patients with cancer. Asymptomatic catheter-related thrombosis was identified via Doppler ultrasound. Bland and Altman's limits of agreement analysis was used to compare sample sites. Sensitivity and specificity of D-dimer was calculated. Results Overall, 33 of the central samples and 32 of the peripheral samples had D-dimer levels below the cutoff (≥0.3 mg/l). Mean central D-dimer was 0.31 ± 0.35 mg/l; peripheral 0.24 ± 0.22 mg/l (p = 0.5). Bland-Altman plot showed that the two sample sites were not equivalent. Catheter-related thrombosis was demonstrated in five patients, and there were three false negatives. Peripheral D-dimer had a negative predictive value of 90.9%. Conclusions A negative D-dimer may be useful for screening asymptomatic catheter-related thrombosis in patients with cancer, but the central and peripheral sample sites are not equivalent.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.