A modified version of the QuEChERS method has been developed for the determination of a group of ten organophosphorus pesticides (i.e. ethoprofos, dimethoate, diazinon, malaoxon, chlorpyrifos-methyl, fenitrothion, malathion, chlorpyrifos, fenamiphos and phosmet) and one thiadiazine pesticide (buprofezin) in three different types of soils (forestal, ornamental and agricultural). The method was validated through linearity, recovery, precision and accuracy studies, and also by carrying out a matrix-matched calibration for the three soils owing to the existence of a strong matrix effect. Acceptable recovery values were obtained (between 45 and 96%) for all the pesticides and soils, except for malathion and malaoxon in forestal and ornamental soils, from which they could not be quantitatively extracted. Limits of detection of the whole method ranged between 0.48 and 7.78 ng/g. The method was finally applied to the determination of chlorpyrifos concentration in a treated soil for cultivation of potatoes.
Room temperature ionic liquids (RTILs) have been used as extraction solvents in dispersive liquid-liquid microextraction (DLLME) for the determination of eight multi-class pesticides (i.e. thiophanate-methyl, carbofuran, carbaryl, tebuconazole, iprodione, oxyfluorfen, hexythiazox, and fenazaquin) in table grapes and plums. The developed method involves the combination of DLLME and high-performance liquid chromatography with diode array detection. Samples were first homogenized and extracted with acetonitrile. After evaporation and reconstitution of the extract in water containing sodium chloride, a quick DLLME procedure that used the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM][PF(6)]) and methanol was developed. The RTIL dissolved in a very small volume of acetonitrile was directed injected in the chromatographic system. The comparison between the calibration curves obtained from standards and from spiked sample extracts (matrix-matched calibration) showed the existence of a strong matrix effect for most of the analyzed pesticides. A recovery study was also developed with five consecutive extractions of the two types of fruits spiked at three concentration levels. Mean recovery values were in the range of 72-100% for table grapes and 66-105% for plum samples (except for thiophanate-methyl and carbofuran, which were 64-75% and 58-66%, respectively). Limits of detection (LODs) were in the range 0.651-5.44 microg/kg for table grapes and 0.902-6.33 microg/kg for plums, representing LODs below the maximum residue limits (MRLs) established by the European Union in these fruits. The potential of the method was demonstrated by analyzing 12 commercial fruit samples (six of each type).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.