The influence of viewing time on the detectability of subtle and obvious lung cancers was studied. Frontal chest radiographs of 40 patients with subtle cancers, 40 patients with obvious cancers, and 40 healthy control subjects were shown to four observers for four different viewing times (0.25 second, 1 second, 4 seconds, and unlimited time). Receiver operating characteristic analysis was used to compare the detectability of lesions. Performance was degraded as viewing time decreased. The true-positive fractions for subtle and obvious cancers were 30% and 70% at 0.25 second and 74% and 98% at unlimited viewing time, respectively, for a given false-positive fraction of 20%. Thus, even with unlimited viewing time, the false-negative fraction for subtle cancers was 26%. The difference in detectability between subtle and obvious lung cancers was exaggerated at 1.0 second compared with 4 seconds and unlimited viewing time. The following conclusions were reached: (a) a substantial proportion of subtle lung lesions are missed, even with unlimited viewing time; (b) a large proportion of obvious lung cancers are detected with flash viewing; (c) the detectability of lesions decreases considerably as viewing time becomes less than 4 seconds; and (d) differences in detectability are exaggerated by short viewing times.
A new dual-screen, dual-emulsion-film combination that allows a decrease in radiation dose of approximately 66% was compared with a widely used single-screen, single-emulsion-film system in contact and magnification mammography. Clustered microcalcifications randomly superimposed on a breast phantom were detected, and the location and number of individual calcifications were determined by four observers. The detectability of calcifications, determined with a receiver operating characteristic (ROC) analysis area, was 0.92 for magnification and 0.82 for contact mammography with the single-emulsion-film system, compared with 0.84 and 0.72, respectively, with the dual-emulsion-film system. More clusters were correctly located and more individual calcifications were counted with magnification than with contact mammography. The dual-emulsion-film system with the magnification technique performs as well as the single-emulsion-film system with the contact technique, while retaining a decrease in required dose of approximately 40%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.