In vivo measurement, not only in animals but also in humans, is a demanding task and is the ultimate goal in experimental biomechanics. For that purpose, measurements in vivo must be performed, under physiological conditions, to obtain a database and contribute for the development of analytical models, used to describe human biomechanics. The knowledge and control of the mechanisms involved in biomechanics will allow the optimization of the performance in different topics like in clinical procedures and rehabilitation, medical devices and sports, among others. Strain gages were first applied to bone in a live animal in 40's and in 80's for the first time were applied fibre optic sensors to perform in vivo measurements of Achilles tendon forces in man. Fibre optic sensors proven to have advantages compare to conventional sensors and a great potential for biomechanical and biomedical applications. Compared to them, they are smaller, easier to implement, minimally invasive, with lower risk of infection, highly accurate, well correlated, inexpensive and multiplexable. The aim of this review article is to give an overview about the evolution of the experimental techniques applied in biomechanics, from conventional to fibre optic sensors. In the next sections the most relevant contributions of these sensors, for strain and force in biomechanical applications, will be presented. Emphasis was given to report of in vivo experiments and clinical applications.
The impact of five different water/powder (w/p) ratios in the characterization of high strength dental stone was evaluated, since the recommendations of the gypsum' manufacturers are not always correctly followed by the dental prosthesis technicians. Fiber Bragg grating (FBG) sensors were used to measure the setting expansion and temperature variation which occurred during the setting reaction for each w/p ratio, as well as the thermal expansion coefficient. Thick mixtures with low w/p ratios had more crystals impinging upon each other during crystal growth, resulting in more expansion and more heat released. This thermal behavior was only achieved to w/p ratios within the manufacturer-recommended mixing ratio range. The results also revealed the existence of boundary condition; this corresponding to the limit of the mixing ratio recommended by the gypsum' manufacturer. Data provided in this study are particularly important for dental technicians with a view to attaining the best results in accuracy of fit for their prosthetic works.
This paper describes the use of fibre Bragg grating (FBG) sensors to measure strains at a mandible surface that are caused by static or impact loads on a dental implant. The measuring apparatus uses a fixed optical filter reference scheme and is able to detect dynamic signals with frequency components of up to 10 kHz. A dried implanted cadaveric mandible was used with strain gauges and FBG sensors placed at the outer surface in the direction of the longitudinal axis of the implant. The implants were loaded statically and dynamically and uniaxial strains recorded. The study demonstrates the ability of the FBG as a biomechanical sensor.
The use of fibre Bragg grating sensors to study dental materials like resin-based composite and gypsum products is reported. Two commercially available composite resins and three types of gypsum products were tested in order to determine polymerization contraction and setting expansion. Temperature and strain evolution during the hardening phase of the material were also obtained. The presented technique can be a good tool for dentists in order to better manipulate a material and predict how it will behave in vivo.
The use of Fibre Bragg Grating sensors to study the setting expansion of dental materials like resin based composites and gypsum is reported. Temperature and strain evolution during the hardening phase of the material are obtained.
This work represents a study of a mathematical model that describes the biological response to different mechanical stimuli in a cellular dynamics model for bone remodelling. The biological system discussed herein consists of three specialised cellular types, responsive osteoblasts, active osteoblasts and osteoclasts, three types of signalling molecules, transforming growth factor beta (TGF-β), receptor activator of nuclear factor kappa-b ligand (RANKL) and osteoprotegerin (OPG) and the parathyroid hormone (PTH). Three proposals for mechanical stimuli were tested: strain energy density (SED), hydrostatic and deviatoric parts of SED. The model was tested in a two-dimensional geometry of a standard human femur. The spatial discretization was performed by the finite element method while the temporal evolution of the variables was calculated by the 4th order Runge-Kutta method. The obtained results represent the temporal evolution of the apparent density distribution and the mean apparent density and thickness for the cortical bone after 600 days of remodelling simulation. The main contributions of this paper are the coupling of mechanical and biological models and the exploration of how the different mechanical stimuli affect the cellular activity in different types of physical activities. The results revealed that hydrostatic SED stimulus was able to form more cortical bone than deviatoric SED and total SED stimuli. The computational model confirms how different mechanical stimuli can impact in the balance of bone homeostasis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.