The aim of the study is to compare the efficacy of SPIO as a tracer in sentinel node biopsy (SNB) in breast cancer with Tc and patent blue in a multicentre prospective study and perform a meta-analysis of all published studies. It also aims to follow skin discoloration after SPIO injection and describe when and how it resolves. Totally 206 patients with early breast cancer were recruited. Tc and patent blue were administered in standard fashion. Patients were injected with SPIO (Sienna+) preoperatively. SNB was performed and detection rates were recorded for both methods. Skin discoloration was followed and documented postoperatively. Data extraction and subsequent meta-analysis of all previous studies were also performed. SN detection rates were similar between standard technique succeeded and SPIO both per patient (97.1 vs. 97.6 %, p = 0.76) as well as per node (91.3 vs. 93.3 %, p = 0.34), something which was not affected by the presence of malignancy. Concordance rates were also consistently high (98.0 % per patient and 95.9 % per node). Discoloring was present in 35.5 % of patients postoperatively, almost exclusively in breast conservation. It fades slowly and is still detectable in 8.6 % of patients after 15 months. Meta-analysis depicted similar detection rates (p = 0.71) and concordance rates (p = 0.82) per patient. However, it seems that SPIO is characterized by higher nodal retrieval (p < 0.001). SPIO is an effective method for the detection of SN in patients with breast cancer. It is comparable to the standard technique and seems to simplify logistics. Potential skin discoloration is something of consideration in patients planned for breast conservation.
Superparamagnetic iron oxide nanoparticles (SPIO) are non-inferior to radioisotope and blue dye (RI + BD) for sentinel lymph node (SLN) detection. Previously, 2 mL SPIO (Sienna+®) in 3 mL NaCl was used. In this dose-optimizing study, lower doses of a new refined SPIO solution (Magtrace®) (1.5 vs. 1.0 mL) were tested in different timeframes (0–24 h perioperative vs. 1–7 days preoperative) and injections sites (subareolar vs. peritumoral). Two consecutive breast cancer cohorts (n = 328) scheduled for SLN-biopsy were included from 2017 to 2019. All patients received isotope ± blue dye as back-up. SLNs were identified primarily with the SentiMag® probe and thereafter a gamma-probe. The primary endpoint was SLN detection rate with SPIO. Analyses were performed as a one-step individual patient-level meta-analysis using patient-level data from the previously published Nordic Trial (n = 206) as a third, reference cohort. In 534 patients, the SPIO SLN detection rates were similar (97.5% vs. 100% vs. 97.6%, p = 0.11) and non-inferior to the dual technique. Significantly more SLNs were retrieved in the preoperative 1.0 mL cohort compared with 1.5 and the 2.0 mL cohorts (2.18 vs. 1.85 vs. 1.83, p = 0.003). Lower SPIO volumes injected up to 7 days before the operation have comparable efficacy to standard SPIO dose and RI + BD for SLN detection.
Background: One-fifth of patients with a preoperative diagnosis of ductal carcinoma in situ (DCIS) have invasive breast cancer (IBC) on definitive histology. Sentinel lymph node dissection (SLND) is performed in almost half of women having surgery for DCIS in Sweden. The aim of the present study was to try to minimize unnecessary SLND by injecting superparamagnetic iron oxide (SPIO) nanoparticles at the time of primary breast surgery, enabling SLND to be performed later, if IBC is found in the primary specimen.Methods: Women with DCIS at high risk for the presence of invasion undergoing breast conservation, and patients with DCIS undergoing mastectomy were included. The primary outcome was whether this technique could reduce SLND. Secondary outcomes were number of SLNDs avoided, detection rate and procedure-related costs.Results: This was a preplanned interim analysis of 189 procedures. IBC was found in 47 and a secondary SLND was performed in 41 women. Thus, 78⋅3 per cent of patients avoided SLND (P < 0⋅001). At reoperation, SPIO plus blue dye outperformed isotope and blue dye in detection of the sentinel node (40 of 40 versus 26 of 40 women; P < 0⋅001). Costs were reduced by a mean of 24⋅5 per cent in women without IBC (€3990 versus 5286; P < 0⋅001).Conclusion: Marking the sentinel node with SPIO in women having surgery for DCIS was effective at avoiding unnecessary SLND in this study. Registration number: ISRCTN18430240
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.