Background: Some studies have advocated the use of suture-button fixation during the Latarjet procedure to reduce complications associated with screw fixation. However, the sample size of these studies is relatively small, and their follow-up period is short. Purpose: To investigate the efficacy of the suture-button Latarjet procedure with at least 3 years of follow-up and remodeling of the coracoid graft. Study Design: Case series; Level of evidence, 4. Methods: A total of 152 patients who underwent the suture-button Latarjet procedure between February 2013 and February 2016 were selected, and 128 patients who met the inclusion criteria were enrolled in this study. Preoperative and postoperative clinical results were assessed. The position and healing condition of the coracoid graft and arthropathy of the glenoid and humeral head were also assessed using radiography and 3-dimensional computed tomography (CT). Results: The mean follow-up time was 40.3 ± 5.8 months. There were 102 patients included in this study. The mean visual analog scale score for pain during motion, the American Shoulder and Elbow Surgeons score, the Rowe score, and the Walch-Duplay score were improved considerably. A total of 100 grafts achieved bone union. The overall absorption rate was 12.6% ± 4.3%. Graft absorption mostly occurred on the edge and outside the “best-fit” circle of the glenoid. A vertical position was achieved in 98 grafts (96% of all cases) immediately postoperatively, with the mean graft midline center at the 4 o’clock position. In the axial view, CT showed that 89 grafts were flush to the glenoid, whereas 2 and 11 grafts were fixed medially and laterally, respectively. In all cases, the bone graft and glenoid tended to extend toward each other to form concentric circles during the remodeling process. During follow-up observations, the height of the 11 grafts that were positioned laterally (ie, above the glenoid level) exhibited a wave-curved change. No arthropathy was observed in any patient. Conclusion: Patient outcomes were satisfactory after the modified arthroscopic suture-button Latarjet technique. Graft absorption mostly occurred on the edge and outside the “best-fit” circle of the glenoid. The graft exhibited the phenomenon of ectatic growing when it fused with the glenoid and finally remodeled to a new concentric circle with the humeral head analogous to the original glenoid. Grafts positioned laterally did not cause arthropathy of the joints within the period of the study.
Background Different substances are combined to compensate for each other’s drawbacks and create an appropriate biomaterial. A novel Polyvinyl alcohol (PVA)/chitosan (CS) porous hydrogel was designed and applied to the treatment of osteochondral defects. Methods Hydrogels of various PVA/CS ratios were tested for physiochemical and mechanical properties in addition to cytotoxicity and biocompatibility. The hydrogels with the best PVA/CS ratio were used in the animal study. Osteochondral defects were created at the articular cartilage of 18 rabbits. They were assigned to different groups randomly ( n = 6 per group): the osteochondral defect only group (control group), the osteochondral defect treated with hydrogel group (HG group), and the osteochondral defect treated with hydrogel loaded with bone marrow mesenchymal stem cells (BMSCs) group (HG-BMSCs group). The cartilage was collected for macro-observation and histological evaluation at 12 weeks after surgery. Results The Hydrogel with PVA/CS ratio of 6:4 exhibited the best mechanical properties; it also showed stable physical and chemical properties with porosity and over 90% water content. Furthermore, it demonstrated no cytotoxicity and was able to promote cell proliferation. The HG-BMSCs group achieved the best cartilage healing. Conclusions The novel PVA/CS porous composite hydrogel could be a good candidate for a tissue engineering material in cartilage repair. Electronic supplementary material The online version of this article (10.1186/s12891-019-2644-7) contains supplementary material, which is available to authorized users.
Although both techniques provided satisfactory clinical results, DB-ACLR using the existing footprint remnant for tunnel placement showed better functional results with respect to faster ROM recovery, higher subjective outcome scores, and better arthroscopic second-look with no revision cases.
DNA methylation has emerged as a crucial regulator of chondrocyte dedifferentiation, which severely compromises the outcome of autologous chondrocyte implantation (ACI) treatment for cartilage defects. However, the full-scale DNA methylation profiling in chondrocyte dedifferentiation remains to be determined. Here, we performed a genome-wide DNA methylation profiling of dedifferentiated chondrocytes in monolayer culture and chondrocytes treated with DNA methylation inhibitor 5-azacytidine (5-AzaC). This research revealed that the general methylation level of CpG was increased while the COL-1A1 promoter methylation level was decreased during the chondrocyte dedifferentiation. 5-AzaC could reduce general methylation levels and reverse the chondrocyte dedifferentiation. Surprisingly, the DNA methylation level of COL-1A1 promoter was increased after 5-AzaC treatment. The COL-1A1 expression level was increased while that of SOX-9 was decreased during the chondrocyte dedifferentiation. 5-AzaC treatment up-regulated the SOX-9 expression while down-regulated the COL-1A1 promoter activity and gene expression. Taken together, these results suggested that differential regulation of the DNA methylation level of cartilage-specific genes might contribute to the chondrocyte dedifferentiation. Thus, the epigenetic manipulation of these genes could be a potential strategy to counteract the chondrocyte dedifferentiation accompanying in vitro propagation. J. Cell. Physiol. 232: 1708-1716, 2017. © 2016 Wiley Periodicals, Inc.
BackgroundRockwood type IV acromioclavicular joint (ACJ) dislocation is a trauma usually needs surgical treatment. Paired EndoButton technique (PET) is used in treating such condition. However, the effect of using different types of PET (single versus double PET) for fixation remains controversial. This study aims to evaluate and compare the efficacy of single and double PET and to provide a suitable option for the surgeons.MethodsWe retrospectively reviewed the charts of patients with acute Rockwood type IV ACJ dislocation who had undergone arthroscopic fixation using single or double PET fixation between March 2009 and March 2015. Seventy-eight consecutive patients identified from chart review were picked and were divided into the single and double PET group with 39 cases in each group. The indexes of visual analog scale score (VAS) for pain, the radiographs of the affected shoulder at different time points of the follow-up, the time of return to activities and sports, the constant functional score, and the Karlsson acromioclavicular joint (ACJ) score, were assessed in a minimum of 2 years postoperation.ResultsThe average coracoclavicular (CC) and acromioclavicular (AC) distances of the affected joints in the double PET group were significantly smaller than those of the single PET group 2 years postoperation (P < 0.05). The average AC and CC distances in the healthy shoulder joints were significantly smaller than those of the affected joints in the single PET group (P < 0.05); however, these values were not significantly different from those of the affected joints in the double PET group (P > 0.05). The mean VAS pain score was not significantly different, while significant difference was found for the number and times of cases return to activities and sports, constant functional score, and Karlsson ACJ score (P < 0.05) between the two groups. Therefore, the double PET group has better outcome than the single PET group. Complications including redislocation, button slippage, erosion, or AC joint instability occurred in the single PET group, while the complication in the double PET group was rare.ConclusionsCompared with the single PET, the double PET group achieved better outcome with less complications in arthroscopically treating acute Rockwood type IV ACJ dislocation.
AimTo evaluate the outcome of arthroscopy treatment using high-strength line in the treatment of tibial avulsion fracture of posterior cruciate ligament.MethodsBoth the avulsed bone block and the tibia bone bed were refreshed. The procedure was completed with the assistance of PCL director drill guide. The reduction and fixation using high-strength line were used to fix the avulsed bone by from posterior middle portal. Rehabilitation began early postoperatively.ResultsFrom January 2010 to June 2012, a total of 18 arthroscopically treated cases of PCL tibial avulsion fracture were retrospectively evaluated. Reduction of the avulsion fragment was obtained in all cases. 16 cases were followed up for 7–30 months (average 13.6), and 2 cases were out of follow-up. In the 16 followed patients, flexion and extension were back to normal within 6 weeks, and return to normal walk in 12 weeks. The bone healing was good without any vascular or nerve complications. All the patients regained the preinjury activity level. The mean score (and standard deviation) increased from 38.9 ± 4.9 points to 95.2 ± 3.8 points with the system of Lysholm, from 57.1 ± 10.3 points to 94.3 ± 4.4 points with the system of IKDC. Post-test displacement of KT3000 declined from 3.6 ± 0.39 to 1.1 ± 0.27 mm.ConclusionArthroscopic vertical fixation by high-strength line is a simple, safe, reliable, and micro-invasive treatment to PCL tibial avulsion fracture. It is a kind of real all arthroscopic technique, and good for early postoperative rehabilitation. The total stability of the knee could be gained, and the second operation to remove the internal fixation is avoided.
Background As several neurologic and hardware complications have been reported with screw fixation. Suture buttons are used to serve as an alternative to screw fixation to obtain better outcome and to reduce the complication. The purpose of this study was to observe the clinical outcomes and make the radiologic assessment of a modified suture button (MSB) arthroscopic Latarjet procedure. Methods A total of ninty-one patients with recurrent shoulder joint dislocation who underwent MSB arthroscopic Latarjet procedure was retrospectively reviewed. Fifty cases identified from the chart review met the inclusion criteria. The clinical outcomes and position of the grafts, glenohumeral degeneration, and graft healing condition were assessed postoperatively in a follow-up with at least one and half of a year. Results All the fifty patients were satisfied with their clinical outcome. The overall complication rate was 4% in this study. The mean visual analog scale score, the affected shoulder active mobility in Ers(external rotation at the side), Era(external rotation in abduction) decreased significantly; the ASES score, Rowe score, Walch-Duplay score improved significantly. CT scans in the sagittal view showed that grafts in 88% of cases were in good position, grafts in 12% of cases were fixed too superiorly and inferiorly. In the axial view grafts in forty cases were flush with the glenoid rim, ten were considered as too lateral. The ten grafts became remodeled and were more flush with the glenoid rim in the follow-up. Conclusions The MSB arthroscopic Latarjet procedure provides excellent outcome with few complications, and no degenerative changes were observed in the follow-up. Moreover, the graft fixed too laterally presented a phenomenon of remodeling and became flush with the glenoid rim over time. Electronic supplementary material The online version of this article (10.1186/s12891-019-2544-x) contains supplementary material, which is available to authorized users.
The combined delivery of BMP-7 and IGF-1 genes using an IRES-based strategy synergistically enhanced differentiation of hPDLCs. It is suggested that this could be a new potential method in gene therapy for periodontal reconstruction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.