Objective: to validate a lumbar spine endoscopic flavectomy simulator using the construct method and to assess the acceptability of the simulator in medical education. Methods: thirty medical students and ten video-assisted surgery experienced orthopedists performed an endoscopic flavectomy procedure in the simulator. Time, look-downs, lost instruments, respect for the stipulated edge of the ligamentum flavum, regularity of the incision, GOALS checklist (Global Operative Assessment of Laparoscopic Skills), and responses to the Likert Scale adapted for this study were analyzed. Results: all variables differed between groups. Procedure time was shorter in the physician group (p < 0.001). Look-downs and instrument losses were seven times greater among students than physicians. Half of the students respected the designated incision limits, compared to 80% of the physicians. In the student group, about 30% of the incisions were regular, compared to 100% in the physician group (p < 0.001). The physicians performed better in all GOALS checklist domains. All the physicians and more than 96% of the students considered the activity enjoyable, and approximately 90% believed that the model was realistic and could contribute to medical education. Conclusions: the simulator could differentiate the groups’ experience level, indicating construct validity, and both groups reported high acceptability.
ObjectiveThe objective of this study is to analyze the surgical results of humeral shaft fracture treatment and describe its epidemiology.MethodsRetrospective study that identified all patients treated with surgical fixation of humeral shaft fractures between December of 2014 and June of 2016 in a trauma reference center. All medical records were reviewed in search of epidemiological data referent to the trauma and post-operative results, including radiographic healing of the fracture and related complications.ResultsFifty-one patients were included, mostly male (78.4%), with an average age of 35.02 years. The most common trauma mechanism was a traffic accident (56.9%) followed by same-level falls (17.6%). No statistically significant difference was found between healing time comparing surgical fixation techniques, including open reduction and internal fixation, minimally invasive technique, intramedullary nailing, and external fixation.ConclusionAlthough each technique has inherent advantages and disadvantages, all fixation methods proved to be adequate options for the surgical treatment of humeral shaft fractures with high rates of healing and low rates of post-operative complications.
Objective: The use of images in 3D reconstruction is an instrument that facilitates the interpretation of the fracture, observations of deviations, rotations and articular surface. Objective: To evaluate the inter-observer and intra-observer reliability of the Neer x AO proximal humerus fracture classification on radiographs versus computed tomography with three-dimensional reconstruction (3D). Methods: We evaluated the digital radiographs (anteroposterior and profile) and computerized tomography with 3D reconstruction of patients presenting with a proximal humerus fracture, surgically treated at an Orthopedics and Traumatology Service. All radiographs and computed tomography were classified (Neer and AO) by eight (8) orthopedic surgeons, specialists in the upper limb and sent, following the pre-established numeration by the author, in a spreadsheet to the author of the study. Results: The Neer and AO scores were more reproducible when determined by computed tomography with 3D reconstruction, mainly in fractures of greater complexity (Neer 4 parts and AO group C). However, in absolute values, inter and intra-observer reproducibility and concordance still remain low. Conclusion: Computed tomography with 3D reconstruction allows a better analysis of fractures of group C and Neer 4 parts. However, the inter and intra-observer agreement does not increase significantly in comparison to the radiographs. Level of evidence III, Study of non-consecutive patients, without gold standard, applied uniformly.
Objectiveto compare healing strength of the infraspinatus tendon of rats with corticoid inoculation, regarding maximum tension, maximum force and rupture force, after injury and experimental repair.Methodsa total of 60 Wistar rats were subjected to tenotomy of the infraspinatus tendon, which was then sutured. Before the surgery, they were divided into a control group (C) inoculated with serum and a study group (S) inoculated with corticoids over the tendon. After repair, the rats were sacrificed in groups of 10 individuals in the control group and 10 in the study group at the times of one week (C1 and S1), three weeks (C3 and S3) and five weeks (C5 and S5). The rats were dissected, separating out the infraspinatus tendon with the humerus. The study specimens were subjected to a traction test, with evaluation of the maximum tension (kgf/cm2), maximum force (kgf) and rupture force (kgf), comparing the study group with the respective control groups.Resultsamong the rats sacrificed one week after the procedure, we observed greater maximum tension in group C1 than in group S1. The variables of maximum force (kgf) and rupture force did not differ statistically between the groups investigated. In the same way, among the rats sacrificed three weeks after the procedure, group C3 only showed greater maximum tension than group S3 (p = 0.007), and the other variables did not present differences. Among the rats sacrificed five weeks after the procedure (C5 and S5), none of the parameters studied presented statistical differences.Conclusionwe concluded that corticoid diminished the resistance to maximum tension in the groups sacrificed one and three weeks after the procedure, in comparison with the respective control groups. The other parameters did not show differences between the study and control groups.
As causas mais frequentes de óbito nos pacientes com lesões inalatórias estão relacionadas à intoxicação por monóxido de carbono (CO). A intoxicação pelo CO se dá pela falta de ar respirável, havendo substituição do oxigênio pelo CO, formando a carboxihemoglobina (COHb). A toxicidade se faz dependente de sua concentração. O artigo em questão avalia a relação da dosagem de COHb associada ao sinal de Montalti positivo, em cadáveres carbonizados, que foram encaminhados ao Instituto de Medicina Legal de Belo Horizonte (IML-BH). O objetivo é de comprovar se os cadáveres em questão vieram a óbito por asfixia ou por outro fator secundário. Para a realização da pesquisa foram feitos levantamentos de dados através de laudos necroscópicos e análises desses, os materiais analisados foram exames de espectrofotometria disponibilizados pelo IML-BH. Foi feito o levantamento dos resultados de COHb e realizado a correlação entre a COHb e o sinal de Montalti, que se mostra positivo quando encontrada fuligem na traqueia. Existiram dificuldades para estabelecer a porcentagem padrão que seria usada como referência para poder se confirmar que a intoxicação foi a causa mortis. Apesar disso, foi possÃvel realizar as dosagens de COHb e fazer correlações dessa com: a faixa etária dos indivÃduos, o nÃvel de drogas de abuso e álcool no sangue e o local que ocorreu a carbonização. Os resultados alcançados demonstram a importância das dosagens feitas para a determinação da causa mortis do indivÃduo, como fator essencial para o fechamento de laudos e investigações.
ResumoO objetivo do presente trabalho é criar um modelo de treinamento em artroscopia de ombro de baixo custo abaixo de 100 dólares, tornando-o acessível à capacitação prática de estudantes de medicina e residentes. O modelo foi criado utilizando um cano de PVC de 150 mm de diâmetro em 90 graus e um modelo de ombro sintético. O posicionamento das peças foi disposto de forma a simular a posição de decúbito lateral com membro superior em tração, frequente nas artroscopias. Para auxiliar no treinamento, foram demarcados pontos coloridos na glenóide e foi confeccionado um modelo de parte do manguito rotador na porção superior da escápula. Foi possível confeccionar um modelo para treinamento de artroscopia do ombro com um valor abaixo de 100 dólares, de fácil manufatura, que pode ser um auxiliar no treinamento de cirurgiões.
ResumoO uso dos fios metálicos, denominados fios de Kirschner, é um método de fixação simples e eficaz para a correção de fraturas e luxações do ombro na cirurgia ortopédica. Uma das possíveis complicações é a migração do fio durante o acompanhamento pós-operatório. Os autores apresentam um caso de um paciente masculino de 48 anos, administrador, que sofreu uma queda de mesmo nível com trauma em ombro direito durante uma partida de futebol. Atendido em um hospital de referência de ortopedia e traumatologia, foi diagnosticada luxação acromioclavicular grau V. Quatro dias após o trauma, fez-se o tratamento cirúrgico da luxação acromioclavicular com amarrilhos com fios de âncora, transferência do ligamento coracoacromial e fixação com fio de Kirchner do acrômio à clavícula. No retorno, 12 dias após o procedimento cirúrgico, identificou-se a migração do fio de Kirschner do bordo do acrômio. Apesar de orientado a se submeter a cirurgia para remoção do fio, o paciente se recusou. Nove meses após o tratamento cirúrgico, o paciente apresentou dores no ombro esquerdo (lado contralateral), dificuldade para mobilizar o ombro, equimose e saliência. Foram feitas radiografias bilaterais e foi constatado que o fio de Kirschner, originalmente no ombro direito, estava no ombro contralateral. Fez-se então cirurgia para remoção do implante, com sucesso.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.