Aims This study aimed to explore whether serum combined with synovial interleukin-6 (IL-6) measurement can improve the accuracy of prosthetic joint infection (PJI) diagnosis, and to establish the cut-off values of IL-6 in serum and synovial fluid in detecting chronic PJI. Methods Patients scheduled to have a revision surgery for indications of chronic infection of knee and hip arthroplasties or aseptic loosening of an implant were prospectively screened before being enrolled into this study. The Musculoskeletal Infection Society (MSIS) definition of PJI was used for the classification of cases as aseptic or infected. Serum CRP, ESR, IL-6, and percentage of polymorphonuclear neutrophils (PMN%) and IL-6 in synovial fluid were analyzed. Statistical tests were performed to compare these biomarkers in the two groups, and receiver operating characteristic (ROC) curves and area under the curve (AUC) were analyzed for each biomarker. Results A total of 93 patients were enrolled. There was no difference in demographic data between both groups. Synovial fluid IL-6, with a threshold of 1,855.36 pg/ml, demonstrated a mean sensitivity of 94.59% (95% confidence interval (CI) 81.8% to 99.3%) and a mean specificity of 92.86% (95% CI 82.7 to 98.0) for detecting chronic PJI. Then 6.7 pg/ml was determined to be the optimal threshold value of serum IL-6 for the diagnosis of chronic PJI, with a mean sensitivity of 97.30% (95% CI 85.8% to 99.9%) and a mean specificity of 76.79% (95% CI 63.6% to 87.0%). The combination of synovial IL-6 and serum IL-6 led to improved accuracy of 96.77% in diagnosing chronic PJI. Conclusion The present study identified that a combination of IL-6 in serum and synovial IL-6 has the potential for further improvement of the diagnosis of PJI. Cite this article: Bone Joint Res 2020;9(9):587–592.
Aims Prosthetic joint infection (PJI) remains a major clinical challenge. Neutrophil CD64 index, Fc-gamma receptor 1 (FcγR1), plays an important role in mediating inflammation of bacterial infections and therefore could be a valuable biomarker for PJI. The aim of this study is to compare the neutrophil CD64 index in synovial and blood diagnostic ability with the standard clinical tests for discrimination PJI and aseptic implant failure. Methods A total of 50 patients undergoing revision hip and knee arthroplasty were enrolled into a prospective study. According to Musculoskeletal Infection Society (MSIS) criteria, 25 patients were classified as infected and 25 as not infected. In all patients, neutrophil CD64 index and percentage of polymorphonuclear neutrophils (PMN%) in synovial fluid, serum CRP, ESR, and serum CD64 index levels were measured preoperatively. Receiver operating characteristic (ROC) curves and the area under the curve (AUC) were analyzed for each biomarker. Results Serum CD64 index showed no significant difference between the two groups (p = 0.091). Synovial fluid CD64 index and PMN% discriminated good differentiation between groups of PJI and aseptic failure with AUC of 0.946 (95% confidence interval (CI) 0.842 to 0.990) and 0.938 (95% CI 0.832 to 0.987) separately. The optimal threshold value of synovial CD64 index for the diagnosis of PJI was 0.85, with a sensitivity of 92.00%, a specificity of 96.00%, and diagnostic odds ratio (DOR) of 227.11. Conclusion The present study demonstrates that CD64 index in synovial fluid could be a promising laboratory marker for screening PJI. The cut-off values of 0.85 for synovial CD64 index has the potential to distinguish aseptic failure from PJI. Cite this article: Bone Joint J 2020;102-B(4):463–469.
Background
Diagnosis of periprosthetic joint infection (PJI), especially chronic PJI, is very confusing and challenging. The value of C-reactive protein (CRP) in infectious diseases has been recognized, but the diagnostic value of CRP in chronic PJI is unknown. Our aim was to investigate the diagnostic value of synovial CRP in chronic PJI and to explore the role of combined serum and synovial CRP in distinguishing chronic PJI from aseptic failure after knee and hip arthroplasties.
Methods
We prospectively enrolled patients scheduled to have a revision surgery for chronic PJI or aseptic loosening from January 2019 to December 2020, in which synovial CRP was additionally measured along with routine preoperative diagnostic serum ((ESR, CRP) and synovial (PMN%) biomarkers. The receiver operating characteristic (ROC) curves and area under the curve (AUC) were analyzed for each biomarker to determine diagnostic efficacy.
Results
There were no statistically significant differences between the infection (n = 39) and aseptic (n = 58) groups, including 61 hips and 36 knees. The synovial CRP levels were significantly higher in the infection group than in the aseptic group (median: 9.93 mg/l vs 3.58 mg/l; p < .001). The optimal cut-off value for detecting chronic PJI of Synovial fluid (SF) CRP was of 7.26 mg/l with a sensitivity of 84.62%, a specificity of 93.10%. The combined model I (Serum CRP > 10.2 mg/l OR SF CRP > 7.26 mg/l) had a negative predictive value (NPV) of 96.67%, and a sensitivity of 97.44%. The combined model II (Serum CRP > 10.2 mg/l AND Synovial CRP > 7.26 mg/l) led to a specificity of 1, and a positive predictive value (PPV) of 1.
Conclusions
The present study demonstrated that the combination of serum and synovial CRP can be used as an adjunct to the diagnosis of chronic PJI.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.