Background:The authors sought to demonstrate the safety and effectiveness of the multilevel stabilization screw (MLSS) technique in decreasing the incidence of proximal junctional failure in long segmental instrumented fusions for adult degenerative scoliosis.Methods:Institutional review board approval was obtained and all patients with adult spinal deformity who underwent the MLSS technique were analyzed. A neuro-radiologist and spine-focused neurosurgeon not involved with the surgical treatment performed radiographic analysis. Proximal junctional angle was defined as the caudal endplate of the upper instrumented vertebra (UIV) to the cephalad endplate of two supradjacent vertebrae above the UIV. The UIV is defined as the most cephalad vertebra completed captured by the instrumentation. Abnormal proximal junctional kyphosis (PJK) was defined as proximal junctional sagittal Cobb angle >10 degrees and proximal junction sagittal Cobb angle at least 10 degrees greater than the preoperative measurement. The presence of both is criteria necessary to be considered abnormal.Results:Twenty patients with degenerative scoliosis underwent the MLSS technique with the upper-instrumented vertebrae in the proximal thoracic spine. Fifteen patients met inclusion criteria with greater than 12 months radiographic and clinical follow up. Three patients were excluded due to lack of follow up imaging and two patients were excluded due to the inability to measure the UIV. Age range was 44–84 years with a mean of 66. Eleven of the 15 patients were over the age of 60 at the time of surgery. The male-to-female ratio was 4:11. Body mass index (BMI) range was 24–44 with a mean of 31.5 units. The follow up period ranged from 14 to 58 months with an average follow up of 30 months. The mean change in Cobb angle at the proximal junction was 4.00 degrees with a range from -0.92 to 9.13 degrees. There were no fractures or instrumentation failures at or near the proximal junction. There was no revision surgeries performed for proximal junctional failure. Retrospective clinical questionnaires revealed that surgical expectations were met in 15 of 19 patients surveyed, 79%. One patient was not reachable for a postoperative phone interview. In patients who were not satisfied with their overall experience, the change in Cobb angle ranged from -0.92 to 9.13 degrees with an average change of 3.90 degrees. Whereas patients reporting an overall positive experience had a change in Cobb angle range from -0.12 to 8.07 degrees with an average change of 4.05 degrees.Conclusion:PJK and failure are well-recognized suboptimal outcomes of long-segmental fusions of the thoracolumbar spine that can lead to significant neurological morbidity and costly revision surgeries. With no known proximal junction failures to date, the MLSS technique has shown promising results in preventing adverse proximal junctional conditions and can be safely performed under fluoroscopy guidance. Future direction includes a comparative study establishing the relative risk of developing PJK ...
Background:The underlying pathophysiology leading to syringomyelia is elusive with multiple flow-related theories constituting our current limited understanding of the disease process. Syringomyelia is associated with pathologies related to the disturbance of cerebral spinal fluid flow found in conditions such as Chiari I malformations, spinal malignancy, spinal cord tethering, trauma, or arachnoid adhesions. Our aim is to describe a unique surgical shunting technique used to treat refractory cases of idiopathic syringomyelia.Methods:Five patients, aged 22-50, presented with progressive neurologic symptoms associated with an idiopathic syrinx. All underwent decompressive laminectomy surgery with syringosubarachnoid shunting using the silastic wedge technique.Results:In five cases of idiopathic syringomyelia, clinical and radiographic follow up ranges from 3 to 36 months. Three patients have radiographic and clinical follow up greater than 24 months. All patients improved clinically and their symptoms have been stable.Conclusions:Shunting procedures for the syringomyelia disease spectrum have been criticized due to the inconsistent long-term outcomes. This surgical technique used to treat symptomatic idiopathic syringomyelia has been devised based on our intraoperative experience, surgical outcomes, and evaluation of the literature. The purpose of the wedges is to preserve patency of the communication between the syrinx cavity and the expanded subarachnoid space by preventing healing of the myelotomy edges and by maintaining an artificial conduit between the syrinx cavity and the subarachnoid space. Although short-term results are promising, continued long-term follow up is needed to determine the ultimate success of the silastic wedge shunting procedure.
AIM:To evaluate the feasibility of this novel surgical approach for treatment of cervical discitis and vertebral osteomyelitis. MATERIAL and METHODS:This is a report of two patients who underwent anterior cervical decompression for discitis and vertebral osteomyelitis (DVO) with cervical spine reconstruction with polymethylmethacrylate impregnated with antibiotics (AI-PMMA). RESULTS:Both patients had successful procedures that were followed by 6 weeks of intravenous antibiotics. Stabilization and eradication of infection was achieved with clinical and radiographic stabilization seen in both. Follow-up is greater than 18 months and both patients remain off antibiotics. CONCLUSION:The described technique using AI-PMMA offers immediate structural stability and local delivery of high concentration of antibiotics. Use in two patients has demonstrated a cost effective, long-term biomechanically stable construct and infection control.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.