The aims of this study were (a) to investigate the acute effects of different drop jump (DJ) accentuated eccentric loading (AEL) protocols and (b) to investigate the effect of these AEL DJ protocols on subsequent countermovement jump (CMJ) performance. The subjects were 12 strength-trained athletes; initially, baseline CMJ performance was assessed and individual optimal DJ drop height identified. In subsequent weeks, subjects completed 1 set of 5 DJs with no additional load or an AEL of 10, 20, or 30% of their individual body mass (BM) using dumbbells to provide the extra load. After the AEL DJ protocols, 3 CMJs were completed after 2, 6, and 12 minutes rest. A generalized linear mixed model was used to investigate the effects of AEL load and time post-DJs on CMJ height, peak power, and ground reaction force. The 20% AEL condition resulted in greater CMJ height in comparison with all other conditions (p < 0.001). CMJ height was significantly greater after 2 and 6 minutes rest compared with 12 minutes (p < 0.001 and p ≤ 0.05 respectively). Greater peak power was also found during the CMJs after the 20% AEL condition compared with baseline, BM, and 10% AEL (p ≤ 0.05). In conclusion, 5 DJs with 20% AEL followed by a 2 minutes recovery period resulted in significant enhancement in CMJ height and peak power.
In this sample of male academy rugby union athletes, the preferred leg and forwards displayed superior strength compared with the nonpreferred leg and backs. These findings highlight the importance of individualized athletic assessments to detect crucial strength differences in male rugby union athletes.
Bridgeman, LA, McGuigan, MR, Gill, ND, and Dulson, DK. Relationships between concentric and eccentric strength and countermovement jump performance in resistance trained men. J Strength Cond Res 32(1): 255-260, 2018-The purpose of this study was to investigate the relationships between concentric and eccentric peak force (PF) and countermovement jump (CMJ) performance in resistance trained men. Subjects were 12 men (mean ± SD; age: 25.4 ± 3.5 years; height: 177.2 ± 4.5 cm; mass: 84.0 ± 10.1 kg). The men were tested for concentric and eccentric PF using the Exerbotics squat device. Subjects then completed 3 CMJs to allow for the calculation of peak power (PP), peak ground reaction force, and jump height (JH). Correlations between the variables of interest were calculated using Pearson product-moment correlation coefficients. A large relationship was found between absolute concentric PF and absolute CMJ PP (r = 0.66, p ≤ 0.05). Absolute eccentric PF had a very large relationship with absolute CMJ PP and CMJ JH (r = 0.74, p < 0.01 and r = 0.74, p < 0.001, respectively). In addition, absolute eccentric PF was found to have a moderate relationship with relative CMJ PP (r = 0.58, p ≤ 0.05). Relative eccentric PF was had a very large relationship with relative CMJ PP and CMJ JH (r = 0.73, p < 0.001 and r = 0.79, p < 0.001, respectively). Based on these findings, strength and conditioning coaches and athletes who wish to enhance CMJ performance may wish to include exercises, which enhance lower-body eccentric strength within their training.
Bridgeman, LA, Gill, ND, Dulson, DK, and McGuigan, MR. The effect of exercise induced muscle damage after a bout of accentuated eccentric load drop jumps and the repeated bout effect. J Strength Cond Res 31(2): 386-394, 2017-Although previous studies have investigated exercise-induced muscle damage (EIMD) after a bout of unloaded drop jumps (DJs), none have investigated the effects of accentuated eccentric load (AEL) DJs on EIMD. The purpose of this study was to investigate the effects of 30 and 50 AEL DJs on strength, jump performance, muscle soreness, and blood markers. Eight resistance trained athletes participated in this study. In week 1, baseline countermovement jump (CMJ), squat jump (SJ), concentric and eccentric peak force (PF), creatine kinase, and muscle soreness were assessed. Subjects then completed 30 AEL DJs and baseline measures were retested immediately postintervention, 1, 24, and 48 hours later. Two weeks later, the subjects completed the same protocol with an increase in AEL DJ volume (50). Subjects' SJ height was reduced in week 1 compared with week 3, postintervention, 1, 24, and 48 hours later (ES = -0.34, -0.44, -0.38, and -0.40). Subjects' CMJ height was reduced in week 1 compared with week 3, postintervention, 1, and 24 hours later (ES = -0.37, -0.29, and -0.39). Concentric PF was reduced in week 1 compared with week 3, postintervention and 24 and 48 hours later (ES = -0.02, -0.23, and -0.32). Eccentric PF was reduced in week 1 compared with week 3, postintervention, 24, and 48 hours later (ES = -0.24, -0.16, and -0.50). In this sample, 30 AEL DJs attenuated the effects of EIMD following which 50 AEL DJs completed 2 weeks later.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.