The use of near-infrared or infrared photons is a promising approach for biomedical imaging in living tissue. This technology often requires exogenous contrast agents with combinations of hydrodynamic diameter, absorption, quantum yield and stability that are not possible with conventional organic fluorophores. Here we show that the fluorescence emission of type II quantum dots can be tuned into the near infrared while preserving absorption cross-section, and that a polydentate phosphine coating renders them soluble, disperse and stable in serum. We then demonstrate that these quantum dots allow a major cancer surgery, sentinel lymph node mapping, to be performed in large animals under complete image guidance. Injection of only 400 pmol of near-infrared quantum dots permits sentinel lymph nodes 1 cm deep to be imaged easily in real time using excitation fluence rates of only 5 mW/cm(2). Taken together, the chemical, optical and in vivo data presented in this study demonstrate the potential of near-infrared quantum dots for biomedical imaging.
AF remains the most common complication after CABG and consequently is a drain on hospital resources. Concerted efforts to reduce the incidence of AF and the associated increased length of stay would result in substantial cost saving and decrease patient morbidity.
To determine whether advances in diagnostic procedures have reduced the value of autopsies, we analyzed 100 randomly selected autopsies from each of the academic years 1960, 1970, and 1980 at one university teaching hospital. In all three eras about 10 per cent of the autopsies revealed a major diagnosis that, if known before death, might have led to a change in therapy and prolonged survival; another 12 per cent showed a clinically missed major diagnosis for which treatment would not have been changed. Among 1980 autopsies, renal disease and pulmonary embolus were less common causes of death than before, but systemic bacterial, viral, and fungal infections increased significantly and were missed clinically 24 per cent of the time. The introduction of radionuclide scans, ultrasound, and computerized tomography as diagnostic procedures did not reduce the use of conventional tests in patients who subsequently died and were studied by autopsy. Over-reliance on these new procedures occasionally contributed directly to missed major diagnoses. We conclude that advances in diagnostic technology have not reduced the value of the autopsy, and that a goal-directed autopsy remains a vital component in the assurance of good medical care.
ObjectiveThis study compares the quality of valve replacement and repair performed through minimally invasive incisions as compared to the standard operation for aortic and mitral valve replacement.
Summary Background DataWith the advent of minimally invasive laparoscopic approaches to orthopedic surgery, urology, general surgery, and thoracic surgery, it now is apparent that standard cardiac valve operations can be performed through very small incisions with similar approaches.
MethodsEighty-four patients underwent minimally invasive aortic (n = 41) and minimally invasive mitral valve repair and replacement (n = 43) between July 1996 and April 1997. Demographics, procedures, operative techniques, and postoperative morbidity and mortality were calculated, and a subset of the first 50 patients was compared to a 50-patient cohort who underwent the same operation through a conventional median sternotomy. Demographics, postoperative morbidity and mortality, patient satisfaction, and charges were compared.
ResultsOf the 84 patients, there were 2 operative mortalities both in class IV aortic patients from multisystem organ failure. There was no operative mortality in the patients undergoing mitral valve replacement or repair. The operations were carried out with the same accuracy and attention to detail as with the conventional operation. There was minimal postoperative bleeding, cerebral vascular accidents, or other major morbidity. Groin cannulation complications primarily were related to atherosclerotic femoral arteries. A comparison of the minimally invasive to the conventional group, although operative time and ischemia time was higher in minimally invasive group, the requirement for erythrocytes was significantly 421
Hypoalbuminemia and low body mass index each independently predict increased morbidity and mortality after cardiac operations. Preoperative risk stratification with the use of body mass index and serum albumin may help to identify subgroups of patients at high risk for adverse outcomes after cardiac operations.
Minimally invasive valve surgery can be performed at very low levels of morbidity and mortality, with results equal to or better than conventional techniques. All forms of valve repair and replacement operations can be performed. Long-term survival and freedom from reoperation are excellent.
Minimally-invasive approaches have become increasingly important in cardiac valve surgery. Smaller incisions have become commonplace in many major centers. We reviewed the existing literature and present the current state-of-the-art of minimally-invasive valve operations in this paper.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.