Seven patients who sustained complex distal femoral fractures above total knee arthroplasties all treated by supracondylar (retrograde) femoral nailing were retrospectively evaluated. All the patients demonstrated uncomplicated postoperative follow-ups and returned to weight bearing between 2 and 3 months after surgery. No delayed healing occurred and alignment of the femur was satisfactory.Résumé Nous avons réalisé une étude rétrospective comprenant sept fractures periprothetiques complexes du fémur distal chez sept porteurs de PTG. Toutes les fractures ont ete traitees par enclouage rétrograde du fémur. L'evolution post-opératoire et la réeducation à la marche étaient sans particularités chez tous les patients. Toutes les fractures ont consolidés sans problemes avec un bon alignement.
A series of 199 total hip arthroplasties was performed using a porous-coated, hemispherical press-fit acetabular cup. At a mean follow-up of 91.5 months 158 cups were available for clinical and radiological review. The mean age of the patients at the time of the index arthroplasty was 62.5 years. The mean Harris Hip score at final follow-up was 87.3. No shells were revised although eccentric polyethylene wear prompted liner replacement in two cases. Osteolysis was noted in six cases but predominantly in relation to the femoral stem. Focal pelvic osteolytic lesions were rare. All the cups were classified as stable on radiography.Résumé Une série de 199 arthroplasties totales de la Hanche a été exécutée utilisant une cupule acétabulaire hémisphérique avec surface réhabitable de type "pressfit". Cent cinquante cupules étaient disponibles pour étude une clinique et radiologique à un suivi moyen de 91.5 mois. L'âge moyen des patients à l'arthroplastie était de 62.5 ans. Le score de Harris au dernier examen était 87.3. Aucune cupule n'a été révisée bien que l'usure du polyéthylène excentrique ait conduit au remplacement du liner dans 2 cas. Une ostéolyse a été notée dans 6 cas, d'une manière prédominante au niveau de la tige fémorale. Toutes les cupules ont été classées comme stables radiologiquement.
A series of 198 total hip arthroplasties was performed using a porous-coated, hemispheric press-fit cup. One hundred and twenty-seven cups were available for clinical and radiological examination at mean followup of 10.6 years. The mean age at the index procedure was 61.2 years. The mean Harris hip score at final follow-up was 89.8. Three cups were revised for aseptic loosening and two liners were changed for eccentric wear and pelvic osteolysis. Nine additional patients showed mild or suspected osteolysis. Two cups were rated "fibrous" stable. There was no correlation between additional screw fixation of the press-fit cup and osteolysis or revision.Résumé Nous avons réalisé une étude rétrospective comprenant 127 prothèses totales de la hanche en utilisant une cupule acetabulaire non cimentée. 'Age moyen des patients lors d'intervention était de 61.2 ans. La durée moyenned' observation post-operatoire était de 10.6 ans. Le score de Harris lors du dernier examen clinique était de 89.9. Trois cupules étaient révisées pour descellement aseptique et deux inserts en polyéthylène étaient changés pour usure et ostéolyse. Neuf autres patients montraient une ostéolyse discrète. Deux cupules étaient stables avec une fixation dite «fibreuse». Aucune corré-lation entre utilisation de vis pour la fixation primaire et le développement d'osteolyse n'a été trouvée.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.