Active-sampling approaches are commonly used for personal monitoring, but are limited by energy usage and data that may not represent an individual’s exposure or bioavailable concentrations. Current passive techniques often involve extensive preparation, or are developed for only a small number of targeted compounds. In this work, we present a novel application for measuring bioavailable exposure with silicone wristbands as personal passive samplers. Laboratory methodology affecting precleaning, infusion, and extraction were developed from commercially available silicone, and chromatographic background interference was reduced after solvent cleanup with good extraction efficiency (>96%). After finalizing laboratory methods, 49 compounds were sequestered during an ambient deployment which encompassed a diverse set of compounds including polycyclic aromatic hydrocarbons (PAHs), consumer products, personal care products, pesticides, phthalates, and other industrial compounds ranging in log Kow from −0.07 (caffeine) to 9.49 (tris(2-ethylhexyl) phosphate). In two hot asphalt occupational settings, silicone personal samplers sequestered 25 PAHs during 8- and 40-h exposures, as well as 2 oxygenated-PAHs (benzofluorenone and fluorenone) suggesting temporal sensitivity over a single work day or week (p < 0.05, power =0.85). Additionally, the amount of PAH sequestered differed between worksites (p < 0.05, power = 0.99), suggesting spatial sensitivity using this novel application.
Currently there is a lack of inexpensive, easy-to-use technology to evaluate human exposure to environmental chemicals, including polycyclic aromatic hydrocarbons (PAHs). This is the first study in which silicone wristbands were deployed alongside two traditional personal PAH exposure assessment methods: active air monitoring with samplers (i.e., polyurethane foam (PUF) and filter) housed in backpacks, and biological sampling with urine. We demonstrate that wristbands worn for 48 h in a non-occupational setting recover semivolatile PAHs, and we compare levels of PAHs in wristbands to PAHs in PUFs-filters and to hydroxy-PAH (OH-PAH) biomarkers in urine. We deployed all samplers simultaneously for 48 h on 22 pregnant women in an established urban birth cohort. Each woman provided one spot urine sample at the end of the 48-h period. Wristbands recovered PAHs with similar detection frequencies to PUFs-filters. Of the 62 PAHs tested for in the 22 wristbands, 51 PAHs were detected in at least one wristband. In this cohort of pregnant women, we found more significant correlations between OH-PAHs and PAHs in wristbands than between OH-PAHs and PAHs in PUFs-filters. Only two comparisons between PAHs in PUFs-filters and OH-PAHs correlated significantly (rs = 0.53 and p = 0.01; rs = 0.44 and p = 0.04), whereas six comparisons between PAHs in wristbands and OH-PAHs correlated significantly (rs = 0.44 to 0.76 and p = 0.04 to <0.0001). These results support the utility of wristbands as a biologically relevant exposure assessment tool which can be easily integrated into environmental health studies. Graphical abstractPAHs detected in samples collected from urban pregnant women Electronic supplementary materialThe online version of this article (10.1007/s00216-018-0992-z) contains supplementary material, which is available to authorized users.
BackgroundFew studies have examined the broad health effects of occupational exposures in flight attendants apart from disease-specific morbidity and mortality studies. We describe the health status of flight attendants and compare it to the U.S. population. In addition, we explore whether the prevalence of major health conditions in flight attendants is associated with length of exposure to the aircraft environment using job tenure as a proxy.MethodsWe surveyed flight attendants from two domestic U.S. airlines in 2007 and compared the prevalence of their health conditions to contemporaneous cohorts in the National Health and Nutrition Survey (NHANES), 2005-2006 and 2007-2008. We weighted the prevalence of flight attendant conditions to match the age distribution in the NHANES and compared the two populations stratified by gender using the Standardized Prevalence Ratio (SPR). For leading health conditions in flight attendants, we analyzed the association between job tenure and health outcomes in logistic regression models.ResultsCompared to the NHANES population (n =5,713), flight attendants (n = 4,011) had about a 3-fold increase in the age-adjusted prevalence of chronic bronchitis despite considerably lower levels of smoking. In addition, the prevalence of cardiac disease in female flight attendants was 3.5 times greater than the general population while their prevalence of hypertension and being overweight was significantly lower. Flight attendants reported 2 to 5.7 times more sleep disorders, depression, and fatigue, than the general population. Female flight attendants reported 34% more reproductive cancers. Health conditions that increased with longer job tenure as a flight attendant were chronic bronchitis, heart disease in females, skin cancer, hearing loss, depression and anxiety, even after adjusting for age, gender, body mass index (BMI), education, and smoking.ConclusionsThis study found higher rates of specific diseases in flight attendants than the general population. Longer tenure appears to explain some of the higher disease prevalence. Conclusions are limited by the cross-sectional design and recall bias. Further study is needed to determine the source of risk and to elucidate specific exposure-disease relationships over time.
To assess differences and trends in personal chemical exposure, volunteers from 14 communities in Africa (Senegal, South Africa), North America (United States (U.S.)) and South America (Peru) wore 262 silicone wristbands. We analysed wristband extracts for 1530 unique chemicals, resulting in 400 860 chemical data points. The number of chemical detections ranged from 4 to 43 per wristband, with 191 different chemicals detected, and 1339 chemicals were not detected in any wristband. No two wristbands had identical chemical detections. We detected 13 potential endocrine disrupting chemicals in over 50% of all wristbands and found 36 chemicals in common between chemicals detected in three geographical wristband groups (Africa, North America and South America). U.S. children (less than or equal to 11 years) had the highest percentage of flame retardant detections compared with all other participants. Wristbands worn in Texas post-Hurricane Harvey had the highest mean number of chemical detections (28) compared with other study locations (10–25). Consumer product-related chemicals and phthalates were a high percentage of chemical detections across all study locations (36–53% and 18–42%, respectively). Chemical exposures varied among individuals; however, many individuals were exposed to similar chemical mixtures. Our exploratory investigation uncovered personal chemical exposure trends that can help prioritize certain mixtures and chemical classes for future studies.
This study investigated the use of postural sway measurements as a potential safety monitoring technique. Sixteen healthy male volunteers (age: 41.8+/-9.3 years) participated in this study. The level of neurophysiological strain and the ability to maintain upright balance for workers wearing personal protective equipment (PPE) were investigated. Three levels of PPE, the United States Environmental Protection Agency (USEPA)-defined levels A, B, and C, were worn in random order while performing two randomly ordered tasks, resting and a workload. After the workload task, the perceived exertion and discomfort were recorded. Postural sway, measured using a microprocessor-based force platform system, was assessed after each task. The variables of sway area and sway length were calculated from stabilograms. These measurements were taken for three sway tests: 1) Eyes open (EO), 2) Eyes closed on a four-inch foam (FC), and 3) a dynamic test with the subject reaching for a weight placed in front, lifting it to his or her chest, and lowering back to the shelf four times (RE). The heart rate was significantly higher for the workload task (p < 0.05), and the levels A and B PPE demonstrated significantly higher perceived exertion results than level C PPE (p < 0.05). The heart rate and perceived exertion were not significantly correlated with the sway measurements. Level A produced significant self-reported discomfort results for the upper back, lower back, and thighs. The sway variables showed significant differences with the PPE levels and the task. The workload task produced significantly higher sway length than the resting task (p < 0.05) for all test conditions. The PPE level B produced significantly higher sway length than PPE level A (p < 0.05) in the FC test condition. These results indicate that postural stability is altered with PPE use and with fatigued postural muscles. In summary, postural sway measurements may be used as a potential safety monitoring technique.
Background Occupational exposure to extremely low frequency magnetic fields (ELF) is a suspected risk factor for brain tumours, however the literature is inconsistent. Few studies have assessed whether ELF in different time windows of exposure may be associated with specific histologic types of brain tumours. This study examines the association between ELF and brain tumours in the large-scale INTEROCC study. Methods Cases of adult primary glioma and meningioma were recruited in seven countries (Australia, Canada, France, Germany, Israel, New Zealand, United Kingdom) between 2000 and 2004. Estimates of mean workday ELF exposure based on a job exposure matrix assigned. Estimates of cumulative exposure, average exposure, maximum exposure, and exposure duration were calculated for the lifetime, and 1–4, 5–9, and 10+ years prior to the diagnosis/reference date. Results There were 3,761 included brain tumour cases (1,939 glioma, 1,822 meningioma) and 5,404 population controls. There was no association between lifetime cumulative ELF exposure and glioma or meningioma risk. However, there were positive associations between cumulative ELF 1–4 years prior to the diagnosis/reference date and glioma (odds ratio (OR) ≥ 90th percentile vs < 25th percentile = 1.67, 95% confidence interval (CI) 1.36–2.07, p < 0.0001 linear trend), and, somewhat weaker associations with meningioma (OR ≥ 90th percentile vs < 25th percentile = 1.23, 95% CI 0.97–1.57, p = 0.02 linear trend). Conclusions Results showed positive associations between ELF in the recent past and glioma. Impact Occupational ELF exposure may play a role in the later stages (promotion and progression) of brain tumourigenesis.
Natural gas extraction (NGE) has expanded rapidly in the United States in recent years. Despite concerns, there is little information about the effects of NGE on air quality or personal exposures of people living or working nearby. Recent research suggests NGE emits polycyclic aromatic hydrocarbons (PAHs) into air. This study used low-density polyethylene passive samplers to measure concentrations of PAHs in air near active (n = 3) and proposed (n = 2) NGE sites. At each site, two concentric rings of air samplers were placed around the active or proposed well pad location. Silicone wristbands were used to assess personal PAH exposures of participants (n = 19) living or working near the sampling sites. All samples were analyzed for 62 PAHs using GC-MS/MS, and point sources were estimated using the fluoranthene/pyrene isomer ratio. ∑PAH was significantly higher in air at active NGE sites (Wilcoxon rank sum test, p < 0.01). PAHs in air were also more petrogenic (petroleum-derived) at active NGE sites. This suggests that PAH mixtures at active NGE sites may have been affected by direct emissions from petroleum sources at these sites. ∑PAH was also significantly higher in wristbands from participants who had active NGE wells on their properties than from participants who did not (Wilcoxon rank sum test, p < 0.005). There was a significant positive correlation between ∑PAH in participants' wristbands and ∑PAH in air measured closest to participants' homes or workplaces (simple linear regression, p < 0.0001). These findings suggest that living or working near an active NGE well may increase personal PAH exposure. This work also supports the utility of the silicone wristband to assess personal PAH exposure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.