Background and Objectives:
There is no clear evidence of a negative impact of biliary stents on the diagnostic yield of EUS-guided fine-needle biopsy (EUS-FNB) for diagnosing pancreatic head lesions. We aimed to evaluate the association between the presence of biliary stents and the diagnostic accuracy of EUS-FNB.
Materials and Methods:
A multicenter retrospective study including all jaundiced patients secondary to pancreatic head masses was performed. Patients were divided into two groups according to the presence of a biliary stent placed before EUS-FNB. Pathological results were classified according to the Papanicolaou classification and compared against the final diagnosis. Diagnostic measures in the two groups were compared. Multivariate logistic regression analyses including potential factors affecting EUS-FNB accuracy were performed.
Results:
Overall, 842 patients were included, 495 (58.8%) without and 347 (41.2%) with biliary stent. A plastic or a metal stent was placed in 217 (62.5%) and 130 (37.5%) cases, respectively. Diagnostic sensitivity and accuracy were significantly higher in patients without biliary stent than in those with stent (91.9% and 92.1%
vs
. 85.9% and 86.4%,
P
= 0.010 At multivariate analyses, lesion size (odds ratio [OR]: 1.05, 95% confidence interval [CI]: 1.02–1.09,
P
= 0.01) and presence of biliary stent (OR: 0.51, 95% CI: 0.32–0.89,
P
= 0.01) were independently associated with diagnostic accuracy. In the subgroup of patients with biliary stent, the type of stent (plastic
vs
. metal) did not impact EUS-FNB yield, whereas the use of larger bore needles enhanced diagnostic accuracy (OR: 2.29, 95% CI: 1.28–4.12,
P
= 0.005).
Conclusions:
In this large retrospective study, an indwelling biliary stent negatively impacted the diagnostic accuracy of EUS-FNB. Preferably, EUS-FNB should precede endoscopic retrograde cholangiopancreatography, especially in the case of small tumors.
Background The advantage of using the macroscopic on-site evaluation (MOSE) technique during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) performed with 22G Franseen needles has not been investigated. We aimed to compare EUS-FNB with MOSE vs. EUS-FNB performed with three needle passes.
Methods This randomized trial involved 10 Italian referral centers. Consecutive patients referred for EUS-FNB of pancreatic or nonpancreatic solid lesions were included in the study and randomized to the two groups. MOSE was performed by gross visualization of the collected material by the endoscopists and considered adequate when a white/yellowish aggregate core longer than 10 mm was retrieved. The primary outcome was diagnostic accuracy. Secondary outcomes were specimen adequacy, number of needle passes, and safety.
Results 370 patients with 234 pancreatic lesions (63.2 %) and 136 nonpancreatic lesions (36.8 %) were randomized (190 EUS-FNB with MOSE and 180 with standard EUS-FNB). No statistically significant differences were found between EUS-FNB with MOSE and conventional EUS-FNB in terms of diagnostic accuracy (90.0 % [95 %CI 84.8 %–93.9 %] vs. 87.8 % [95 %CI 82.1 %–92.2 %]; P = 0.49), sample adequacy (93.1 % [95 %CI 88.6 %–96.3 %] vs. 95.5 % [95 %CI 91.4 %–98 %]; P = 0.31), and rate of adverse events (2.6 % vs. 1.1 %; P = 0.28). The median number of passes was significantly lower in the EUS-FNB with MOSE group (1 vs. 3; P < 0.001).
Conclusions The accuracy of EUS-FNB with MOSE is noninferior to that of EUS-FNB with three needle passes. MOSE reliably assesses sample adequacy and reduces the number of needle passes required to obtain the diagnosis with a 22G Franseen needle.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.