BACKGROUNDThe possible advantage of hybrid closed-loop therapy (i.e., artificial pancreas) over sensor-augmented pump therapy in very young children with type 1 diabetes is unclear.
METHODSIn this multicenter, randomized, crossover trial, we recruited children 1 to 7 years of age with type 1 diabetes who were receiving insulin-pump therapy at seven centers across Austria, Germany, Luxembourg, and the United Kingdom. Participants received treatment in two 16-week periods, in random order, in which the closedloop system was compared with sensor-augmented pump therapy (control). The primary end point was the between-treatment difference in the percentage of time that the sensor glucose measurement was in the target range (70 to 180 mg per deciliter) during each 16-week period. The analysis was conducted according to the intention-to-treat principle. Key secondary end points included the percentage of time spent in a hyperglycemic state (glucose level, >180 mg per deciliter), the glycated hemoglobin level, the mean sensor glucose level, and the percentage of time spent in a hypoglycemic state (glucose level, <70 mg per deciliter). Safety was assessed.
Aims/hypothesis-Young children who develop multiple autoantibodies (mAbs) are at very high risk for type 1 diabetes. We assessed whether a population with mAbs detected by screening is also at very high risk, and how risk varies according to age, type of autoantibodies and metabolic status.
Background: The COVID-19 pandemic has impacted the conduct of clinic visits. We conducted a study to evaluate two academic laboratories' fingerstick capillary blood collection kits suitable for home use for laboratory measurement of HbA1c. Methods: Four clinical sites recruited 240 participants (aged 4-80 years, HbA1c 5.1%-13.5%). Capillary blood samples were obtained by the participant or parent using collection kits from two laboratories (University of Minnesota Advanced Research and Diagnostic Laboratory (ARDL) and Children's Mercy Hospital Laboratory (CMH)) and mailed under varying shipping conditions by United States Postal Service to the laboratories. Comparisons were made between HbA1c measurements from capillary samples and contemporaneously obtained venous samples. The primary outcome was percentage of capillary HbA1c values within 5% of the corresponding venous values. Results: HbA1c values were within 5% of venous values for 96% of ARDL kit specimens shipped with a cold pack and 98% without a cold pack and 99% and 99%, respectively, for the CMH kits. R 2 values were 0.98, 0.99, 0.99, and 0.99, respectively. Results appeared similar across HbA1c levels and for pediatric and adult participants. Usability survey scores were high. Conclusions: Capillary blood collection kits, suitable for home use, from two academic laboratories, were demonstrated to be easy to use and provided results that are comparable with those obtained from venous specimens. Based on these results, there is strong evidence that HbA1c measurements from capillary specimens obtained with these specific kits can be used interchangeably with HbA1c measurements from venous specimens for clinical research and clinical care.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.