Introduction Robotic-assisted surgery techniques are increasing in total knee arthroplasty (TKA). One crucial point is the prolonged time of surgery. The primary objective of this study was to determine the learning curve necessary to minimize the time of surgery. The secondary objective was to evaluate the accuracy of the implant alignment when using an imageless robotic system for TKA. Materials and methods In a case–control study, the first 70 consecutive robotic-assisted TKA procedures performed by a single senior surgeon were analyzed with regard to surgery time and implant alignment by comparing the intraoperative plan with the postoperative alignment. The evaluation of the learning curve with respect to surgery time was conducted using cumulative summation (CUSUM) analysis. The joint line height was measured with a new technique. Surgery time and joint line reconstruction were compared to 70 consecutive conventional TKA procedures. Results The learning curve for robotic TKA was completed after 11 cases. The learning curve did not influence the accuracy of joint line obliquity, joint line height, or limb alignment. The intraoperative plan designed for the robotic system was precisely implemented. The mean skin-to-skin time in the robotic group after the learning curve was completed did not differ from that in the manual group. A significant positive correlation was observed between the preoperative hip–knee–ankle angle and the postoperative distalization of the joint line in the robotic-assisted TKA group. Conclusion After completing the initial learning curve of 11 cases, the surgery time required to perform imageless robotic handpiece-assisted TKA was similar to that for the conventional technique. However, no learning curve was observed for the implant positioning when using the imageless robotic system. The implementation of the intraoperative plan was accurate up to < 2°. The precision of the system allows the implementation of different joint balancing approaches between valgus and varus morphotypes.
Purpose: Symptomatic horizontal instability is clinically relevant following acute acromioclavicular joint dislocations. However, the intrinsic healing response is poorly understood. The present study sought to investigate timedependent healing responses of the human acromioclavicular ligament following acute traumatic rupture. Methods: Biopsies of the acromioclavicular ligament were obtained from patients undergoing surgical treatment for acute acromioclavicular joint dislocations. Specimens were stratified by time between trauma and surgery: group 1, 0-7 days (n = 5); group 2, 8-14 days (n = 6); and group 3, 15-21 days (n = 4). Time-dependent changes in cellularity, collagen (type 1 and 3) concentration, and histomorphological appearance were evaluated for the rupture and intact zone of the acromioclavicular ligament. Results: Group 1 was characterized by cellular activation and early inflammatory response. The rupture zone exhibited a significantly higher count of CD68-positive cells than the intact zone (15.2 vs 7.4; P ≤ 0.05). Consistently, synovialization of the rupture end was observed. Within the second week, the rupture zone was subject to proliferation showing more fibroblast-like cells than the intact zone (66.8 vs 43.8; P ≤ 0.05) and a peak of collagen type 3 expression (group 1: 2.2 ± 0.38, group 2: 3.2 ± 0.18, group 3: 2.8 ± 0.57; P ≤ 0.05). Signs of consolidation and early remodeling were seen in the third week. Conclusions: The acromioclavicular ligament exhibits early and dynamic healing responses following acute traumatic rupture. Our histological findings suggest that surgical treatment of acute ACJ dislocations should be performed as early as possible within a timeframe of 1 week after trauma to exploit the utmost biological healing potential. Prospective clinical studies are warranted to investigate whether early surgical treatment of ACJ dislocations translates into clinical benefits.
Periprosthetic joint infection (PJI) remains one of the most common causes of revision knee arthroplasty. Controversy continues to surround the proper operative technique of PJI in knee arthroplasty with single- or two-stage replacement. Significant variations are seen in the eradication rates of PJI and in implant survival rates. This detailed retrospective analysis of a single tertiary center is intended to provide further data and insight comparing single- and two-stage revision surgery. A retrospective analysis of all revision total knee arthroplasty (TKA) surgeries from 2013 to 2019 was performed and screened with respect to single- or two-stage TKA revisions. Single- and two-stage revisions were analyzed with regard to implant survival, revision rate, microbiological spectrum, and other typical demographic characteristics. A total of 63 patients were included, with 15 patients undergoing single-stage revision and 48 patients undergoing two-stage revision. The mean follow-up time was 40.7 to 43.7 months. Statistically, no difference was found between both groups in overall survival (54.4% vs. 70.1%, p = 0.68) and implant survival with respect to reinfection (71.4% vs. 82.4%, p = 0.48). Further, high reinfection rates were found for patients with difficult-to-treat organisms and low- to semi-constrained implant types, in comparison to constrained implant types. A statistically comparable revision rate for recurrence of infection could be shown for both groups, although a tendency to higher reinfection rate for single-stage change was evident. The revision rate in this single-center study was comparably high, which could be caused by the high comorbidity and high proportion of difficult-to-treat bacteria in patients at a tertiary center. In this patient population, the expectation of implant survival should be critically discussed with patients.
Purpose This study aimed to validate a new joint line measurement technique in total knee arthroplasty for separated assessment of the medial and lateral femoral joint line alteration with 3D-surface scan technology. Separate assessment of the medial and lateral joint line alteration may improve TKA alignment assessment regarding to joint line restoration in kinematic alignment and use of robotic-assisted TKA surgery. Methods The medial and lateral joint line difference after TKA implantation on an artificial bone model was analyzed and compared with a 3D-scan and full femoral radiographs pre- and postoperatively. Radiographic analysis included the perpendicular distance between the most distal point of the medial and lateral condyle and the reproduced preoperative lateral distal femoral angle (LDFA). For evaluation of validity and reliability, radiographs were captured initially with true anteroposterior view and subsequently with combined flexion and rotation malpositioning. Reliability of the introduced measurement technique in between three observers was tested with intraclass correlation coefficient (ICC). Results Radiographic measurement showed a mean difference of 0.9 mm on the medial side and 0.6 mm on the lateral side when compared to the 3D-surface scan measurement. The reliability of measurement accuracy was ≤ 1 mm in x-rays with < 10° flexion error regardless to malrotation in these images. The ICC test showed very good reliability for the medial joint line evaluation and good reliability for lateral joint line evaluation (ICC 0.92, ICC 0.86 respectively). Conclusion The new introduced joint line measurement method showed a sufficient reliability, accuracy and precision. It provides separated information about medial and lateral joint line alteration in TKA surgery in absolute values. Level of evidence V - Experimental Study
Purpose The purpose of this study was to examine the predictive value concerning clinical outcome and implant survival, as well as the accuracy of individual tests of a recently published radiographic decision aid for unicondylar knee arthroplasty indication findings. Methods In the retrospective part of the study, 98 consecutive patients who had undergone unicondylar knee arthroplasty (Phase 3 Oxford medial UKA) were included, using revision questionnaires, as well as the Forgotten Joint Score‐12 (FJS‐12) and Knee Osteoarthritis Outcome Score (KOOS) and analysed for suitability of the radiographic decision aid. Inappropriate and appropriate indications were then compared concerning the clinical outcome and implant survival. The prospective part of the study assessed the accuracy of the decision aid's radiographic tests (varus and valgus stress views, true lateral view and skyline view), and included 90 patients. Definition as appropriate for UKA procedure included medial bone‐on‐bone situation in varus stress views, full‐thickness lateral cartilage and functional medial collateral ligament in valgus stress views, functional anterior cruciate ligament (ACL) in true lateral views and absence of lateral facet osteoarthritis with bone loss in skyline views. Pre‐operative radiographic assessment with respect to the decision aid was then compared with intraoperative articular conditions. The clinical outcome was analysed using non‐parametric tests (Mann–Whitney U), and revision rates were compared using the Fisher's exact test. Accuracy assessment included calculations of the sensitivity, specificity, negative predictive value and positive predictive value. A p value < 0.05 was considered statistically significant. Results Appropriate unicondylar knee arthroplasty with respect to the decision aid showed a significantly lower revision rate compared to inappropriate unicondylar knee arthroplasty (7.3% vs. 50.0%, p < 0.0001), as well as higher clinical outcome scores (FJS‐12: 53.13 vs. 31.25, p = 0.041 and KOOS‐QDL: 68.75 vs. 50.0, p = 0.036). The overall sensitivity (70.1%) and specificity (76.2%) for the radiographic decision aid was comparably low, which was essentially based on false negative cases (22.7%) regarding medial bone‐to‐bone conditions. Conclusion The radiographic decision aid is a helpful tool to predict clinical outcome and implant survival of mobile‐bearing unicondylar knee arthroplasty. Strict use of the radiographic decision aid may lead to increased exclusion of appropriate patients with unicondylar knee arthroplasty implantation.
Purpose It is known that in uni-compartmental knee arthroplasty (UKA) low-volume surgeons have a higher complication and revision rate than high-volume surgeons. Further, robotic-assisted UKA leads to lower early revision rate as well as fewer limb and joint line outliers compared to conventional UKA. The purpose of this study was to retrospectively analyze the outliers’ and revision rate of low-volume UKA surgeons with different robotic systems at short-term follow-up. Methods In this case–control study, 103 robotic-assisted UKAs were included. The procedures were performed between 2016 and 2019 from two low-volume UKA surgeons with an imageless (IL) (63 patients) and image-based (IB) (40 patients) robotic system. Alignment outliers, joint line (JL) reconstruction, complication and revision rates of the two different robotic systems were analyzed. The minimum follow-up was two years. Outliers were defined as a postoperative valgus malalignment greater than 182°. The surgery time for all procedures was evaluated. Results The overall revision rate was 3.9% (4 of 103). Two occurred in the IB group (5.0%) and two in the IL group (3.2%). No valgus malalignment outliers were observed in both groups. The mean JL was not distalized by more than 2 mm in both groups (IL: 1.3 ± 1.6 mm vs. IB: 1.8 ± 0.9 mm, p value 0.08). The IL procedures had a significant lower mean surgery time (55 ± 13 min vs. 68 ± 14, p value 0.001). Conclusion Robotic-assisted UKA is a safe procedure in the hand of low-volume UKA surgeons. Robotic-assisted UKA minimizes overcorrection into valgus mal-alignment. Low revision rates are observed at short-term follow-up for robotic-assisted UKA. The choice of the different robotic systems has no impact on the outcome.
Background Horizontal instability following acute acromioclavicular joint (ACJ) reconstruction still occurs with a high prevalence. Although the human acromioclavicular ligament complex (ACLC) represents the major horizontal ACJ stabilizer, experimental studies on healing characteristics are lacking. Therefore, the purpose of this histological study was to investigate the healing potential of the ACLC following acute anatomical reconstruction Methods In this prospective clinical-experimental study, 28 ACLC biopsies were performed in patients with complete ACJ dislocations (Rockwood type 4 or 5) during acute hook plate stabilization (IG: implantation group; n = 14) and hook plate removal (EG: explantation group; n = 14). Histological analyses included Giemsa staining, polarized light microscopy and immunostaining against CD68, αSMA and collagen type I and type III. Histomorphological evaluation entailed cell counts, collagen expression score, ligament tissue maturity index (LTMI) and descriptive analysis of specific ligamentous structures. Statistics consisted of nonparametric Mann–Whitney U tests and a level of significance of P < .05. Results Total cell counts (cells/mm2 1491 ± 296 vs. 635 ± 430; P < 0.001) and collagen III expression (3.22 ± 0.22 vs. 1.78 ± 0.41; P < 0.001) were higher in EG compared to IG. Inversely αSMA + (11 ± 9 vs. 179 ± 186; P < 0.001) and CD68 + cell counts (56 ± 20 vs. 100 ± 57; P 0.009) were significantly lower in the EG. The EG revealed a comparable reorientation of ligamentous structures. Consistently, ACLC samples of the EG (21.6 ± 2.4) displayed a high total but differently composed LTMI score (IG: 24.5 ± 1.2; P < 0.001). Conclusions This experimental study proved the ligamentous healing potential of the human ACLC following acute anatomical reconstruction. Histomorphologically, the ACLC reliably showed a ligamentous state of healing at a mean of about 12 weeks after surgery. However, processes of ligamentous remodeling were still evident. These experimental findings support recent clinical data showing superior horizontal ACJ stability with additional AC stabilization in the context of acute ACJ reconstruction. Though, prospective clinical and biomechanical studies are warranted to evaluate influencing factors on ACLC healing and potential impacts of acute ACLC repair on clinical outcome. Study type Controlled Laboratory Study
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.