Background.
The optimal method of oxygen delivery to donor kidneys during ex vivo machine perfusion has not been established. We have recently reported the beneficial effects of subnormothermic (22°C) blood perfusion in the preservation of porcine donation after circulatory death kidneys. Since using blood as a clinical perfusate has limitations, including matching availability and potential presence of pathogen, we sought to assess hemoglobin-based oxygen carrier (HBOC-201) in oxygen delivery to the kidney for renal protection.
Methods.
Pig kidneys (n = 5) were procured after 30 minutes of warm in situ ischemia by cross-clamping the renal arteries. Organs were flushed with histidine tryptophan ketoglutarate solution and subjected to static cold storage or pulsatile perfusion with an RM3 pump at 22°C for 4 hours with HBOC-201 and blood. Thereafter, kidneys were reperfused with normothermic (37°C) oxygenated blood for 4 hours. Blood and urine were subjected to biochemical analysis. Total urine output, urinary protein, albumin/creatinine ratio, flow rate, resistance were measured. Acute tubular necrosis, apoptosis, urinary kidney damage markers, neutrophil gelatinase-associated lipocalin 1, and interleukin 6 were also assessed.
Results.
HBOC-201 achieved tissues oxygen saturation equivalent to blood. Furthermore, upon reperfusion, HBOC-201 treated kidneys had similar renal blood flow and function compared with blood-treated kidneys. Histologically, HBOC-201 and blood-perfused kidneys had vastly reduced acute tubular necrosis scores and degrees of terminal deoxynucleotidyl transferase 2'-deoxyuridine, 5'-triphosphate nick end labeling staining versus kidneys treated with cold storage. Urinary damage markers and IL6 levels were similarly reduced by both blood and HBOC-201.
Conclusions.
HBOC-201 is an excellent alternative to blood as an oxygen-carrying molecule in an ex vivo subnormothermic machine perfusion platform in kidneys.
Introduction
The current methods of preserving donor kidneys in nonoxygenated cold conditions minimally protect the kidney against ischemia-reperfusion injury (IRI), a major source of complications in clinical transplantation. However, preserving kidneys with oxygenated perfusion is not currently feasible due to the lack of an ideal perfusion mechanism that facilitates perfusion with blood at warm temperature. Here, we have designed an innovative renal pump circuit system that can perfuse blood or acellular oxygen carrier under flexible temperatures, pressures, and oxygenation. We have tested this apparatus to study optimal conditions of storage of our porcine model of donation after cardiac death (DCD) kidneys.
Methods
Porcine kidneys were retrieved after 30 minutes of cross-clamping renal pedicles
in situ
. Cessation of blood mimics postcardiac death in humans and simulates DCD warm ischemic injury. Procured kidneys were flushed and subjected to static cold storage (SCS) for 4 hours. For warm perfusion, kidneys were cannulated for pulsatile oxygenated perfusion with blood:PlasmaLyte for 4 hours at 15 °C, 22 °C, and 37 °C. To mimic posttransplant scenario, all kidneys were reperfused with blood for an additional 4 hours at 37 °C.
Results
Compared with all other groups, 22 °C perfusion resulted in significant reduction of acute tubular necrosis (ATN), apoptosis, kidney damage markers, Toll-like receptor signaling, and cytokine production. It was associated with maximal renal blood flow and urine output. Kidneys stored at 15 °C thrombosed within 2 hours under this condition. Martius Scarlet Blue staining confirmed that 22 °C was the optimal temperature to minimize hemorrhage and blood clots.
Conclusion
Our novel study shows that oxygenated perfusion at near-room-temperature provides optimal donor kidney storage conditions.
Carbon monoxide releasing molecules-401 provides renal protection after cold storage of kidneys and provides a novel clinically relevant ex vivo organ preservation strategy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.