Aims
Data on ventricular pulsed-field ablation (PFA) are sparse in the setting of chronic myocardial infarction (MI). The objective of this study was to compare the biophysical and histopathologic characteristics of PFA in healthy and MI swine ventricular myocardium.
Methods and results
Myocardial infarction swine (n = 8) underwent coronary balloon occlusion and survived for 30 days. We then performed endocardial unipolar, biphasic PFA of the MI border zone and a dense scar with electroanatomic mapping and using an irrigated contact force (CF)-sensing catheter with the CENTAURI System (Galaxy Medical). Lesion and biophysical characteristics were compared with three controls: MI swine undergoing thermal ablation, MI swine undergoing no ablation, and healthy swine undergoing similar PFA applications that included linear lesion sets. Tissues were systematically assessed by gross pathology utilizing 2,3,5-triphenyl-2H-tetrazolium chloride staining and histologically with haematoxylin and eosin and trichrome. Pulsed-field ablation in healthy myocardium generated well-demarcated ellipsoid lesions (7.2 ± 2.1 mm depth) with contraction band necrosis and myocytolysis. Pulsed-field ablation in MI demonstrated slightly smaller lesions (depth 5.3 ± 1.9 mm, P = 0.0002), and lesions infiltrated into the irregular scar border, resulting in contraction band necrosis and myocytolysis of surviving myocytes and extending to the epicardial border of the scar. Coagulative necrosis was present in 75% of thermal ablation controls but only in 16% of PFA lesions. Linear PFA resulted in contiguous linear lesions with no gaps in gross pathology. Neither CF nor local R-wave amplitude reduction correlated with lesion size.
Conclusion
Pulsed-field ablation of a heterogeneous chronic MI scar effectively ablates surviving myocytes within and beyond the scar, demonstrating promise for the clinical ablation of scar-mediated ventricular arrhythmias.
OBJECTIVES: Guidewire retention after intravascular catheter insertion is considered a "never event. " Prior reports attribute this complication to various characteristics including uncooperative patients, operator inexperience, off-hour or emergent insertion, and underutilization of ultrasound guidance. In this descriptive analysis of consecutive events, we assessed the frequency of patient, operator, and procedural factors in guidewire retention.
DESIGN:Pre-specified observational analysis as part of a quality improvement study of consecutive guidewire retention events across a multihospital health system from August 2007 to October 2015.
Radiofrequency (RF) ablation can be a source of electromagnetic interference (EMI) for cardiovascular implantable electronic devices (CIEDs). The response of CIEDs to this type of EMI can be variable and unpredictable. We report a case with an uncommon response where there was a failure to deliver pacing pulses to both atrial and ventricular pacing leads during RF ablation close to the atrial lead even when the pacemaker was set to pace asynchronously. We also explain the mechanism behind this unusual pacemaker response.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.