Results are presented related to the ablation of animal cartilage by a XeCl laser beam (308 nm). In particular the minimum energy flux for ablation and the ablation rate as a function of the energy flux were measured. The effect of the pulse repetition rate on the cartilage temperature and the influence of a flowing cooling gas were also investigated. A new method, based on the observation of the acoustic wave produced during the ablation process and the delay of arrival of the wave to the back of the sample with respect to the laser pulse, was introduced to measure the ablation threshold and the on line ablation rate. This method was compared with other methods that use either a profilometer or the perforation of the sample to measure the ablation rate. It is shown that the acoustic method can provide accurate, on line information of the ablation rate and threshold. It is also shown that the ablation rate is reduced considerably along the depth of the sample.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.