Introduction: This paper explores the potential of the StyleGAN model as an high-resolution image generator for synthetic medical images. The possibility to generate sample patient images of different modalities can be helpful for training deep learning algorithms as e.g. a data augmentation technique. Methods: The StyleGAN model was trained on Computed Tomography (CT) and T2-weighted Magnetic Resonance (MR) images from 100 patients with pelvic malignancies. The resulting model was investigated with regards to three features: Image Modality, Sex, and Longitudinal Slice Position. Further, the style transfer feature of the StyleGAN was used to move images between the modalities. The root-mean-squard error (RMSE) and the Mean Absolute Error (MAE) were used to quantify errors for MR and CT, respectively. Results: We demonstrate how these features can be transformed by manipulating the latent style vectors, and attempt to quantify how the errors change as we move through the latent style space. The best results were achieved by using the style transfer feature of the StyleGAN (58.7 HU MAE for MR to CT and 0.339 RMSE for CT to MR). Slices below and above an initial central slice can be predicted with an error below 75 HU MAE and 0.3 RMSE within 4 cm for CT and MR, respectively. Discussion: The StyleGAN is a promising model to use for generating synthetic medical images for MR and CT modalities as well as for 3D volumes.
Recent developments in magnetic resonance (MR) to synthetic computed tomography (sCT) conversion have shown that treatment planning is possible without an initial planning CT. Promising conversion results have been demonstrated recently using conditional generative adversarial networks (cGANs). However, the performance is generally only tested on images from one MR scanner, which neglects the potential of neural networks to find general high-level abstract features. In this study, we explored the generalizability of the generator models, trained on a single field strength scanner, to data acquired with higher field strengths. T2-weighted 0.35T MRIs and CTs from 51 patients treated for prostate (40) and cervical cancer (11) were included. 25 of them were used to train four different generators (SE-ResNet, DenseNet, U-Net, and Embedded Net). Further, an ensemble model was created from the four network outputs. The models were validated on 16 patients from a 0.35T MR scanner. Further, the trained models were tested on the Gold Atlas dataset, containing T2-weighted MR scans of different field strengths; 1.5T(7) and 3T(12), and 10 patients from the 0.35T scanner. The sCTs were dosimetrically compared using clinical VMAT plans for all test patients. For the same scanner (0.35T), the results from the different models were comparable on the test set, with only minor differences in the mean absolute error (MAE) (35-51HU body). Similar results were obtained for conversions of 3T GE Signa and the 3T GE Discovery images (40-62HU MAE) for three of the models. However, larger differences were observed for the 1.5T images (48-65HU MAE). The overall best model was found to be the ensemble model. All dose differences were below 1%. This study shows that it is possible to generalize models trained on images of one scanner to other scanners and different field strengths. The best metric results were achieved by the combination of all networks.
Purpose: Radiochromic film dosimetry is extensively used for quality assurance in photon and proton beam therapy. So far, GafchromicTM EBT3 film appears as a strong candidate to be used in future magnetic resonance (MR) based therapy systems. The response of Gafchromic EBT3 films in the presence of magnetic fields has already been addressed for different MR-linacs systems. However, a detailed evaluation of the influence of external magnetic fields on the film response and calibration curves for proton therapy has not yet been reported. This study aims to determine the dose responses of EBT3 films for clinical proton beams exposed to magnetic field strengths up to 1 T in order to investigate the feasibility of EBT3 film as an accurate dosimetric tool for a future MR particle therapy system (MRPT). Methods: The dosimetric characteristics of EBT3 films were studied for a proton beam passing through magnetic field strengths of B = 0, 0.5, and 1 T. Absorbed dose calibration and measurements were performed using clinical proton beams in the nominal energy range of 62.4-252.6 MeV. Irradiations were done using an in-house developed PMMA slab phantom placed in the center of a dipole research magnet. Monte Carlo (MC) simulations using the GATE/Geant4 toolkit were performed to predict the effect of magnetic fields on the energy deposited by proton beams in the phantom. Planned and measured doses from 3D box cube irradiations were compared to assess the accuracy of the dosimetric method using EBT3 films with/without the external magnetic field. Results: Neither for the mean pixel value nor for the net optical density, any significant deviations were observed due to the presence of an external magnetic field (B ≤ 1T) for doses up to 10 Gy. Doseresponse curves for the red channel were fitted by a three-parameter function for the field-free case and for B = 1T, showing for both cases an R-square coefficient of unity and almost identical fitting parameters. Independently of the magnetic field, EBT3 films showed an under-response as high as 8% in the Bragg peak region, similarly to previously reported effects for particle therapy. No noticeable influence of the magnetic field strength was observed on the quenching effect of the EBT3 films. Conclusions: For the first time detailed absorbed dose calibrations of EBT3 films for proton beams in magnetic field regions were performed. Results showed that EBT3 films represent an attractive solution for the dosimetry of a future MRPT system. As film response functions for protons are not affected by the magnetic field strenght, they can be used for further investigations to evaluate the dosimetric effects induced due to particle beams bending in magnetic fields regions.
Purpose: The melanin-concentrating hormone receptor 1 (MCHR1) has become an important pharmacological target, since it may be involved in various diseases, such as diabetes, insulin resistance, and obesity. Hence, a suitable positron emission tomography radiotracer for the in vivo assessment of the MCHR1 pharmacology is imperative. The current paper contrasts the extensive in vitro, in vivo, and ex vivo assessments of the radiotracers [18 F]FE@SNAP and were conducted on adherent Chines hamster ovary (CHO-K1) cells stably expressing the human MCHR1 and MCHR2. Small animal imaging studies on mice and rats were performed under displacement and baseline conditions, as well as after pretreatment with the Pglycoprotein/breast cancer resistant protein inhibitor tariquidar. After the imaging studies, detailed analyses of the ex vivo biodistribution were performed. Ex vivo metabolism was determined in rat blood and brain and analyzed at various time points using a quantitative radio-HPLC assay.Cécile Philippe and Markus Zeilinger contributed equally to this work.C o r r e s p o n d e n c e t o : M a r k u s M i t t e r h a u s e r ; e -m a i l :
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.