PurposeTo assess the longitudinal changes in optical quality including intraocular scattering in normal eyes and eyes with short tear breakup time (TBUT).MethodsWe prospectively examined twenty eyes of 20 healthy subjects, and age-matched twenty eyes of 20 short TBUT subjects. The modulation transfer function (MTF) cutoff frequency, the Strehl ratio, and the objective scattering index (OSI) were quantitatively assessed using an Optical Quality Analysis System. We investigated the changes in these variables measured consecutively at the initial examination, 5, and 10 seconds without blinking. We also compared these variables in eyes with short TBUT with those in normal eyes.ResultsNo significant differences in the MTF cutoff frequency, Strehl ratio, or OSI were detected over a 10-second period in normal eyes. These variables also became significantly degraded even over a 5-second period in eyes with short TBUT (p<0.01). We found significant differences in these variables at 5 and 10 seconds (p<0.05), but none immediately after the blink between normal and short TBUT eyes.ConclusionsOptical quality including intraocular scattering deteriorated significantly with time in eyes with short TBUT, whereas we found significant differences over a 10-second period in normal eyes. Eyes with short TBUT showed greater deterioration in optical quality after the blink than normal eyes. The longitudinal assessment of optical quality may be effective in distinguishing eyes with short TBUT from normal eyes.
Purpose. To objectively determine the effects of pupil size on optical quality parameters in astigmatic eyes using a double-pass instrument. Methods. We examined twenty-two eyes of 22 healthy volunteers (mean age ± standard deviation, 27.1 ± 2.8 years) who had no ophthalmic diseases other than refractive errors (manifest cylinder ≤0.25 diopters (D)). After we fully corrected cycloplegic refraction, we created with-the-rule astigma tism of 1, 2, and 3 diopters in these eyes and then quantitatively assessed the modulation transfer function (MTF) cutoff frequency and the Strehl2D ratio with 2-, 4-, and 6-mm pupil sizes using the Optical Quality Analysis System. Results. The MTF cutoff frequency and the Strehl2D ratio decreased significantly as the amount of astigmatism increased at each pupil size (P < 0.001 for 2, 4, and 6 mm, analysis of variance). They also decreased significantly with an increase in pupil size at each diopter of astigmatism (P < 0.001 for 0, 1, 2, and 3 D). Multiple comparisons demonstrated a significant difference between measurements made for a 2-mm pupil and for a 6-mm pupil at each diopter of astigmatism (P < 0.001 for 0, 1, 2, and 3 D, Dunnett test) and those made for a 4-mm pupil and for a 6-mm pupil at each diopter of astigmatism (P < 0.001 for 0 D, P < 0.05 1, 2, and 3 D). Conclusions. Eyes with larger pupils had lower optical quality even when they were astigmatic. It may be necessary to correct the preexisting astigmatism to acquire excellent visual performance, especially in astigmatic eyes with larger pupils.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.