Undesirable condenser tube leaks frequently occur in power plants, resulting in reduced power output, increased burden on downstream systems, and substantial revenue losses. Current techniques such as wood flour provide temporary in situ remediation but lack adhesive properties to form stable seals. Here, we report the development of in situ sealants for long-term defect repair. The carboxylic acids on graphene oxides and Claisen graphene were used as chemical handles to covalently install a bio-inspired, adhesive catechol, generating a class of functional graphenic material (FGM) sealants. FGM sealants outperformed unfunctionalized scaffolds with enhanced antimicrobial activity to prevent fouling (up to 55% reduction) and superior cohesive properties to promote stable seals. Further, FGM sealants were adhesive, effectively sealing defects in a model experiment, whereas unfunctionalized scaffolds did not display any sealant capacity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.