The present study examined the potential use of polar organic chemical integrative samplers (POCIS) for exposure assessment of munitions constituents, including 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), and their breakdown products (aminodinitrotoluenes [ADNTs], diaminonitrotoluenes [DANTs], and hexahydro-1,3,5-trinitroso-1,3,5-triazine [TNX]). Loss of munitions constituents from the sorbent phase after uptake was observed for the "pesticide" POCIS configuration but not for the "pharmaceutical" configuration. Therefore, the latter was selected for further investigation. Under constant exposure conditions, TNT, ADNTs, DANT, RDX, and atrazine (a common environmental contaminant) accumulated at a linear rate for at least 14 d, with sampling rates between 34 mL/d and 215 mL/d. When POCIS were exposed to fluctuating concentrations, analyte accumulation values were similar to values found during constant exposure, indicating that the sampler was indeed integrative. In contrast, caffeine (a common polar contaminant) and TNX did not accumulate at a linear rate and had a reduction in accumulation of greater than 50% on the POCIS during fluctuating exposures, demonstrating that POCIS did not sample those chemicals in an integrative manner. Moreover, in a flow-through microcosm containing the explosive formulation Composition B, TNT and RDX were readily measured using POCIS, despite relatively high turnover rates and thus reduced water concentrations. Mean water concentrations estimated from POCIS were ± 37% of mean water concentrations measured by traditional grab sample collection. Thus, POCIS were found to have high utility for quantifying exposure to most munitions constituents evaluated (TNT, ADNTs, and RDX) and atrazine.
Cyclopiazonic acid (α-CPA) is a tremorgenic mycotoxin that is commonly produced by certain species of the aspergilli, in particular Aspergillus flavus, which is more widely known for production of the aflatoxins. Despite the fact that α-CPA may co-occur with aflatoxins, immunoassay-based methods for monitoring for CPA have not been widely developed. We report the development and evaluation of several monoclonal antibodies (mAbs) for α-CPA. Two mAbs in particular were very sensitive, with ICs of 1.1 and 1 ng/mL (clones 1418 and 1231, respectively). Tolerances to aqueous methanol or acetonitrile were good, which permitted the development of an antigen-immobilized competitive enzyme-linked immunosorbent assay (CI-ELISA) for detection of CPA in maize. Spiked or naturally contaminated maize, extracted with aqueous methanol, was diluted with buffer for analysis. The working range for the assay (IC to IC) was from 5 to 28 μg/kg. Recoveries from maize spiked over the range from 2 to 50 μg/kg averaged 88.6 ± 12.6%. Twenty-eight samples of maize were tested by both the CI-ELISA and a liquid chromatography-fluorescence (LC-FLD) method. For the five samples above the limits of quantitation of both methods, CI-ELISA tended to overestimate CPA content, a difference that we speculate may be due to related metabolites or perhaps "masked" derivatives of CPA. The antibodies developed and the resulting CI-ELISA will be useful tools for further evaluation of the prevalence of this mycotoxin in maize.
Fumonisins are a group of mycotoxins that routinely contaminate maize. Their presence is monitored at multiple stages from harvest to final product. Immunoassays are routinely used to screen commodities in the field while laboratory-based methods, such as mass spectrometry (MS), are used for confirmation. The use of a portable mass spectrometer unlocks the potential to conduct confirmatory analyses outside of traditional laboratories. Herein, a portable mass spectrometer was used to measure fumonisins in maize. Samples were extracted with aqueous methanol, cleaned up on an immunoaffinity column, and tested with the portable MS. The limits of detection were 0.15, 0.19, and 0.28 mg/kg maize for fumonisins B1 (FB1), FB2/FB3, and total fumonisins, respectively. The corresponding limits of quantitation in maize were 0.33, 0.59, and 0.74 mg/kg. Recoveries ranged from 93.6% to 108.6%. However, RSDs ranged from 12.0 to 29.8%. The method was applied to the detection of fumonisins in 64 samples of maize collected as part of the Illinois Department of Agriculture’s monitoring program. Good correlations were observed between the portable MS and a laboratory-based LC-MS method (r2 from 0.9132 to 0.9481). Results suggest the portable MS can be applied to the measurement of fumonisins in maize at levels relevant to international regulations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.