Participants showed a significant improvement in speech recognition in noise when comparing four remote microphone systems with different wireless transmission methods to hearing aids alone.
This study aimed to document improvements in speech recognition when listening through fixed or adaptive directional microphone arrays relative to listening through omnidirectional microphone arrays in a variety of near-field noise conditions. Twelve participants with mild to severe hearing loss were recruited. Data were analyzed in a manner to facilitate discussion of both group and individual performance. The activation of directional microphones significantly improved speech recognition in all listening conditions when compared to omnidirectional listening conditions. Significant differences in speech recognition performance were not observed between fixed and adaptive directional microphone conditions. Analysis of individual outcomes shows a wide range of both absolute speech recognition scores and directional benefit across treatment conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.