Microperforated panels (MPPs) are typically made of a thin metal or plastic panel and are often unsuitable for an interior finish because thin limp panels do not have enough strength. In particular, an interior finish of room walls requires appropriate strength. In order to solve this problem, a honeycomb structure is attached behind MPPs to stiffen the construction. Thus, it is possible to stiffen an MPP without increasing its thickness, which is important to keep MPPs at their best absorption performance. Furthermore, a honeycomb can increase MPPs’ absorption coefficient in a similar way as a porous layer backed by a honeycomb. In this study, an experiment was performed to gain insight into the acoustical effect of a honeycomb structure behind MPPs and a simple theoretical model to interpret the experimental effects is presented. The experimental results show that the honeycomb affects the absorption characteristics of MPPs: the absorption peak increases and shifts to lower frequencies. This effect becomes more significant as the thickness of the honeycomb increases. The results from the theoretical model show the same tendency. This is attributed to the fact that the honeycomb makes a similar condition to local reaction in the back cavity.
The aim of this study was clarify the effects of reducing various functional pressures essential for the maintenance of bone homeostasis. Femoral bone mineral density (BMD) and biological apatite (BAp) crystallite alignment were measured in conventionally reared and hindlimb-unloaded mice. The femur was divided into 10 equal segments perpendicular to the longitudinal axis of the bone and measurements were performed on the cortical bone in the five segments closest to the midpoint of the femur. Significantly lower BMD and BAp alignment in the longitudinal (Z-axis) direction were observed in the hindlimb-unloaded group. The present findings suggest that unloading by tail suspension significantly decreases not only mouse femoral bone mass but also BAp crystallite alignment, although minimal uniaxial preferential alignment is retained.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.