Abstract. Fibre optic distributed temperature sensing (DTS) is widely applied in Earth sciences. Many applications require a spatial resolution higher than that provided by the DTS instrument. Measurements at these higher resolutions can be achieved with a fibre optic cable helically wrapped on a cylinder. The effect of the probe construction, such as its material, shape, and diameter, on the performance has been poorly understood. In this article, we study data sets obtained from a laboratory experiment using different cable and construction diameters, and three field experiments using different construction characteristics. This study shows that the construction material, shape, diameter, and cable attachment method can have a significant influence on DTS temperature measurements. We present a qualitative and quantitative approximation of errors introduced through the choice of auxiliary construction, influence of solar radiation, coil diameter, and cable attachment method. Our results provide insight into factors that influence DTS measurements, and we present a number of solutions to minimize these errors. These practical considerations allow designers of future DTS measurement set-ups to improve their environmental temperature measurements.
Distributed temperature sensing has proven a useful technique for geoscientists to obtain spatially distributed temperature data. When studies require high‐resolution temperature data in three spatial dimensions, current practices to enhance the spatial resolution do not suffice. For example, double‐diffusive phenomena induce sharp and small‐scale temperature patterns in water bodies subject to thermohaline gradients. This article presents a novel approach for a 3‐D dense distributed temperature sensing setup, the design of which can be customized to the required spatial resolution in each dimension. Temperature is measured along fiber‐optic cables that can be arranged as needed. In this case, we built a dense cage of very thin (1.6 mm) cables to ensure that interference with flow patterns was minimal. Application in water bodies with double‐diffusion‐induced sharp temperature gradients shows that the setup is well able to capture small‐scale temperature patterns and even detects small unsuspected seeps and potential salt‐fingers. However, the potential effect of the setup on the flow patterns requires further study.
In this article, we rehabilitate the integrating rising bubble technique as an effective means of obtaining discharge measurements. Since Sargent (1981, 1982a), the technique has not been applied widely, mainly as a result of practical difficulties. We hypothesize that modern image processing techniques can greatly improve the rising bubble technique. We applied the technique in both a laboratory setup and a field study, after determining the bubble rising velocity for our nozzles in the specific case. During our measurements, we captured digital photographs of the bubble envelope at the water surface, each picture being a single measurement of the discharge. The photographs were corrected for lens distortion and reprojected so that accurate distances on water surface level could be obtained. This easy digital procedure resulted in accurate discharge measurements, even when turbulence was involved and the averages of multiple image analyses yielded good results. The study shows that the rising bubble technique can be a preferable discharge gauging technique in some situations. Recent developments in image processing facilitate the method substantially
Abstract. Fibre optic Distributed Temperature Sensing (DTS) is widely applied in earth sciences. Many applications require a spatial resolution higher than the provided by the DTS instrument. Measurements at these higher resolutions can be achieved with a fibre optic cable helically wrapped on a cylinder. The effect of the probe construction, such as its material, shape, and diameter, on the performance has been poorly understood. In this article, we study datasets obtained from a laboratory experiment using different cable and construction diameters, and three field experiments using different construction characteristics. This study shows that the construction material, shape, diameter, and cable attachment method can have a significant influence on DTS temperature measurements. We present a qualitative and quantitative approximation of errors introduced through the choice of auxiliary construction, influence of solar radiation, coil diameter, and cable attachment method. Our results provide insight into factors that influence DTS measurements, and we present a number of solutions to minimize these errors. These practical considerations allow designers of future DTS measurement setups to improve their environmental temperature measurements.
Abstract:The urban heat island effect was first described 200 years ago, but the development of ways to mitigate heat in urban areas reaches much further into the past. Uchimizu is a 17th century Japanese tradition, in which water is sprinkled around houses to cool the ground surface and air by evaporation. Unfortunately, the number of published studies that have quantified the cooling effects of uchimizu are limited and only use surface temperature or air temperature at a single height as a measure of the cooling effect. In this research, a dense three-dimensional Distributed Temperature Sensing (DTS) setup was used to measure air temperature with high spatial and temporal resolution within one cubic meter of air above an urban surface. Six experiments were performed to systematically study the effects of (1) the amount of applied water; (2) the initial surface temperature; and (3) shading on the cooling effect of uchimizu. The measurements showed a decrease in air temperature of up to 1.5 • C at a height of 2 m, and up to 6 • C for near-ground temperature. The strongest cooling was measured in the shade experiment. For water applied in quantities of 1 mm and 2 mm, there was no clear difference in cooling effect, but after application of a large amount of water (>5 mm), the strong near-ground cooling effect was approximately twice as high as when only 1 mm of water was applied. The dense measurement grid used in this research also enabled us to detect the rising turbulent eddies created by the heated surface.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.