The neuropeptide oxytocin (OT) is associated with a plethora of social behaviors, and is a key topic at the intersection of psychology and biology. However, tools for measuring OT are still not fully developed. We describe a robust nano liquid chromatography-mass spectrometry (nanoLC-MS) platform for measuring the total amount of OT in human plasma/serum. OT binds strongly to plasma proteins, but a reduction/alkylation (R/A) procedure breaks this bond, enabling ample detection of total OT. The method (R/A + robust nanoLC-MS) was used to determine total OT plasma/serum levels to startlingly high concentrations (high pg/mL-ng/mL). Similar results were obtained when combining R/A and ELISA. Compared to measuring free OT, measuring total OT can have advantages in e.g. biomarker studies.
This paper presents for the first time a phenomenological theoretical model for the time dependent distribution of analytes during electromembrane extraction (EME). The model was verified experimentally for a range of model drugs and peptides. Analytes were extracted from an acidified aqueous sample solution, through an organic supported liquid membrane (SLM), and into an acidified aqueous acceptor solution. Mass transfer was governed by an applied electric field across the SLM. A rapid depletion was seen in the sample during extractions, with a steady increase in the amount accumulated in the acceptor solution. This was in good accordance with the theoretical model. A deviation from the modeled behavior was seen for some of the peptides where trapping of analyte in the SLM was high. The results demonstrated for the first time that EME behaved like a distribution system, with voltage dependent distribution coefficients. In addition, electrokinetic migration was observed across the SLM, which added an electrophoretic component to the mass transfer. This improved theoretical understanding will be highly beneficial for future optimization and development of applications using EME.
A large screening of different components in the supported liquid membrane (SLM) in electromembrane extraction (EME) was performed to test the extraction efficiency on eight model peptides. Electromembrane extraction from a 500 μL acidified aqueous sample containing the model peptides in the concentration 10 μg/mL was used. Extraction time was 5 min with an electric potential of 10 V and 900 rpm agitation of the sample vial. The samples were extracted through a hollow fiber-based SLM with different compositions of organic solvents and carriers. A small volume of acidified acceptor solution (25 μL) was after extraction analyzed directly, or with some dilution, on CE or HPLC. This article has identified mono- or di-substituted phosphate groups as the prominent group of carrier molecules needed to obtain acceptable recoveries. For the organic solvents, primary alcohols and ketones have shown promise regarding recovery and reproducibility, with some differences in selectivity. A new composition of the SLM, namely 2-octanone and tridecyl phosphate (90:10 w/w) has proved to give higher extraction recoveries and lower standard deviation than SLMs previously reported in the literature.
The current work presents a large systematic screening of 61 possible organic solvents used as supported liquid membranes (SLM) in electromembrane extraction (EME). For each organic solvent, recovery, current across the SLM, and stability considerations have been investigated and correlated to relevant solvent properties through partial least square regression analysis. The five unpolar basic drugs pethidine, haloperidol, methadone, nortriptyline, and loperamide were used as model analytes. Efficient EME solvents were found to have a low water solubility (<0.5 g L(-1)) and belonged to cluster 2 of a Kamlet-and-Taft-based solvent classification system (high dipole moments and proton acceptor properties). These parameters were especially found in nitroaromatic compounds and ketones. Small molecules with low log P value and high water solubility were unsuitable, as they tended to give unstable extractions, caused by a high current across the SLM. This was often combined with substantial solvent-related interferences and the generation of an electroosmotic flow across the SLM, with resulting acceptor solution expansion. Large molecules with a high log P value were classified as inefficient. For these solvents, no current was measured across the SLM and no analytes were extracted. This is the first time systematic knowledge on the SLM in EME has been gathered and investigated, and the presented results could be highly beneficial for future development and optimization of EME.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.