Purpose We performed two parallel systematic reviews and meta-analyses to determine the association between early migration of tibial components and late aseptic revision.Methods One review comprised early migration data from radiostereometric analysis (RSA) studies, while the other focused on revision rates for aseptic loosening from long-term survival studies. Thresholds for acceptable and unacceptable migration were determined according to that of several national joint registries: < 5% revision at 10 years.Results Following an elaborate literature search, 50 studies (involving 847 total knee prostheses (TKPs)) were included in the RSA review and 56 studies (20,599 TKPs) were included in the survival review. The results showed that for every mm increase in migration there was an 8% increase in revision rate, which remained after correction for age, sex, diagnosis, hospital type, continent, and study quality. Consequently, migration up to 0.5 mm was considered acceptable during the first postoperative year, while migration of 1.6 mm or more was unacceptable. TKPs with migration of between 0.5 and 1.6 mm were considered to be at risk of having revision rates higher than 5% at 10 years.Interpretation There was a clinically relevant association between early migration of TKPs and late revision for loosening. The proposed migration thresholds can be implemented in a phased, evidence-based introduction of new types of knee prostheses, since they allow early detection of high-risk TKPs while exposing only a small number of patients.
PurposeThere is renewed interest in the all-polyethylene tibial component in total knee arthroplasty (TKA). Long-term results of this prosthesis in rheumatoid arthritis (RA) patients, however, are limited. Therefore, we studied 104 primary cemented all-polyethylene tibial TKA in 80 consecutive RA patients for up to 25 years to determine the long-term survival of all-polyethylene tibial components in patients suffering from end stage RA.MethodsWe estimated revision rates according the revision rate per 100 observed component years used in national joint registries. Kaplan–Meier was used to estimate survival curves.ResultsDuring the 25-year follow-up, three revisions for tibial component loosening were performed. The mean revision rate of all-polyethylene tibial components with revision for aseptic loosening as the endpoint was 0.09 per 100 observed component years. This corresponds to a revision rate of 0.9% after ten years and 2.25% after 25 years. Survivorship according to Kaplan–Meier was 100% at ten years and 87.5% at 25 years [95% confidence interval (CI) 64.6–100)].ConclusionThis study shows good long-term results of all-polyethylene tibial TKA in patients with RA. RA patients with multiple-joint inflammation may be less physically active than osteoarthritis patients, resulting in a lower demand on the prosthesis, and these patients may, indeed, be good candidates for all-polyethylene tibial TKA. Our results suggest that all-polyethylene tibial TKA could be a successful and cost-saving treatment for end-stage knee arthritis in RA patients.
Purpose The aim of this study was to develop a more accurate method to deal with patients lost to follow-up based on the competing risks approach. Methods A cohort of 112 patients who received 143 primary cemented total knee arthroplasties forms the basis for this study. Follow-up was up to 25 years. The new method for dealing with lost to follow-up accounts for competing events (i.e. death and failure of a prosthesis) using the cumulative incidence estimator and estimates time to event for patients lost to follow-up using national demographic registries. The results of this new method were compared with the worst case scenario estimated by Kaplan-Meier. Results Six different situations were identified covering all possible situations in long-term follow-up for total knee arthroplasty. The new method-considering all patients lost to follow-up as revised-showed a twofold reduction in revision rate compared to the traditional worst case scenario using Kaplan-Meier. Conclusions Lost to follow-up should be prevented whenever possible, but this may be unavoidable for long-term follow-up studies. In situations where lost to follow-up does occur, the new proposed method offers an efficient and valid approach to deal with this problem.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.