A 64-year-old male had an awake right nasal fiber-optic intubation with an endotracheal tube for open reduction and internal fixation of bilateral displaced mandibular fractures. After induction of anesthesia, an 18 Fr nasogastric tube (NGT) was inserted through the left nostril and was secured. The patient required high flow rates to deliver adequate tidal volumes with the ventilator. A chest x-ray done in the postanesthesia care unit revealed a malpositioned NGT in the left lower lobe bronchus, which was immediately removed. The patient was extubated on postoperative day 2. Various traditional methods, such as aspiration of gastric contents, auscultation of gastric insufflations, and chest x-ray are in use to detect or prevent the misplacement of an NGT. These methods can be unreliable or impractical. Use of capnography to detect an improperly placed NGT should be considered in the operating room as a simple, cost-effective method with high sensitivity to prevent possibly serious sequelae of an NGT placed within the bronchial tree.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.