The orbit is contained within a complex bony architecture with overlying soft tissue that involves many important anatomical structures. Orbital trauma is a frequent cause of damage to these structures. The authors review the literature on reconstructive techniques focusing on fractures of the orbital rim, orbital roof, orbital floor, medial orbital wall, and naso-orbito-ethmoid complex. A thorough literature review was conducted using PubMed analyzing articles relevant to the subject matter. Various search terms were used to identify articles regarding orbital trauma presentation, diagnosis, management, as well as postoperative complications. Articles were examined by all authors and pertinent information was gleaned for the purpose of generating this review. Orbital trauma can result in a wide variety of complications in form and function. Not all orbital fractures require operative repair. However, bony disruption can cause enophthalmos, hypophthalmos, telecanthus, epiphora, cerebrospinal fluid leaks, orbital hematoma, and even blindness to name a few. Timing of operative repair as well as reconstructive method is dictated by the patient's individual presentation. Successful fracture management requires a detailed understanding of the anatomy and pathophysiology to ensure restoration of the patients' preoperative state. Orbital trauma encompasses a wide variety of mechanisms of injury and resulting fracture patterns. A variety of surgical approaches to the orbit exist as has been discussed allowing the surgeon access to all area of interest. Regardless of the fracture complexity, the principles of atraumatic technique, anatomic reduction, and stable fixation apply in all cases.
Objectives Automated external defibrillators (AEDs) are lifesaving, but little is known about where they are located or how to find them. We sought to locate AEDs in high employment areas of Philadelphia and characterize the process of door-to-door surveying to identify these devices. Methods Block groups representing approximately the top 3rd of total primary jobs in Philadelphia were identified using the US Census Local Employment Dynamics database. All buildings within these block groups were surveyed during regular working hours over six weeks during July-August 2011. Buildings were characterized as publically accessible or inaccessible. For accessible buildings, address, location type, and AED presence were collected. Total devices, location description and prior use were gathered in locations with AEDs. Process information (total people contacted, survey duration) was collected for all buildings. Results Of 1420 buildings in 17 block groups, 949 (67%) were accessible, but most 834 (88%) did not have an AED. 283 AEDs were reported in 115 buildings (12%). 81 (29%) were validated through visualization and 68 (24%) through photo because employees often refused access. In buildings with AEDs, several employees (median 2; range 1–8) were contacted to ascertain information, which required several minutes (mean 4; range 1–55). Conclusions Door-to-door surveying is a feasible, but time-consuming method for identifying AEDs in high employment areas. Few buildings reported having AEDs and few permitted visualization, which raises concerns about AED access. To improve cardiac arrest outcomes, efforts are needed to improve the availability of AEDs, awareness of their location and access to them.
Background Tranexamic acid (TXA) is an antifibrinolytic that has become widely used in aesthetic facial plastic surgery, although its efficacy has not been well investigated. Objectives To evaluate the existing evidence for use of TXA in aesthetic facial plastic surgery, highlighting routes of administration, dosing, surgical applications, and clinical outcomes. Methods Systematic review of primary literature evaluating TXA in aesthetic facial plastic surgery. Results Eleven studies met inclusion criteria: 8 prospective randomized controlled trials, 2 retrospective case series/cohort studies, and 1 clinical opinion. Six studies evaluated TXA in rhinoplasty, 4 in rhytidectomy, and 1 in blepharoplasty. Significant reductions in intraoperative blood loss were found in 5 rhinoplasty studies. Three rhinoplasty and 2 rhytidectomy studies found significantly reduced postoperative edema and ecchymosis. One rhinoplasty and 1 rhytidectomy study reported reduced operative time and time to achieve hemostasis. One rhytidectomy study reported reduced postoperative drain output and faster time to drain removal. No studies reported an adverse outcome directly related to TXA. Conclusions Existing literature investigating TXA in aesthetic facial plastic surgery is sparse with varying levels of evidence and heterogeneous data. Literature suggests systemic TXA reduces intraoperative blood loss during rhinoplasty, although the clinical significance of this blood loss reduction is unclear. TXA may also reduce postoperative edema and/or ecchymosis in rhytidectomy and rhinoplasty, although the lack of validated grading scales yields insufficient evidence to support this claim. Topical and subcutaneously injected TXA are emerging administration routes in rhytidectomy, with evidence suggesting TXA mixed with tumescent may reduce postoperative drain output, thereby expediting drain removal. Level of Evidence: 2
4. Laryngoscope, 128:818-822, 2018.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.