Applications of Micro-Electro-Mechanical Systems (MEMS) sensors have developed rapidly in the last decade, increasing the need of Failure Analysis (FA) to characterize abnormalities and to identify failure modes of various types of MEMS devices. One of the greatest challenges is removal of the sealing cap from the MEMS device without any impact to the moveable sensing elements. A novel non-destructive technique has been successfully developed using KOH wet chemical etching followed by application of ex-situ hand sticking to deprocess the sealing cap from an accelerometer device. This new approach provides a quick and reliable way to remove the sealing cap from a MEMS device.
This paper demonstrates a new de-process flow for MEMS motion sensor failure analysis, using layer by layer deprocessing to locate defect points. Analysis tools used in this new process flow include IR optical microscopy, thermal system, SEM and a cutting system to de-process of MEMS motion sensor and successful observation defect points.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.