T reatment of patients with acute ischemic stroke (AIS) is aimed at reopening occluded arteries and reestablishment of intracranial perfusion. Determining pivotal characteristics about the occluding thrombus using available imaging has the potential to improve patient's diagnostics and prognostics.Background and Purpose-Preclinical studies showed that thrombi can be permeable and may, therefore, allow for residual blood flow in occluded arteries of patients having acute ischemic stroke. This perviousness may increase tissue oxygenation, improve thrombus dissolution, and augment intra-arterial treatment success. We hypothesize that the combination of computed tomographic angiography and noncontrast computed tomography imaging allows measurement of contrast agent penetrating a permeable thrombus, and it is associated with improved outcome. Methods-Thrombus and contralateral artery attenuations in noncontrast computed tomography and computed tomographic angiography images were measured in 184 Multicenter Randomized Clinical trial of Endovascular treatment of acute ischemic stroke in the Netherlands (MR CLEAN) patients with thin-slice images. Two quantitative estimators of the thrombus permeability were introduced: computed tomographic angiography attenuation increase (Δ) and thrombus void fraction (ε). Patients were dichotomized as having a pervious or impervious thrombus and associated with outcome, recanalization, and final infarct volume. Results-Patients with Δ≥10.9 HU (n=81 [44%]) and ε≥6.5% (n=77 [42%]) were classified as having a pervious thrombus.These patients were 3.2 (95% confidence interval, 1.7-6.4) times more likely to have a favorable outcome, and 2.5 (95% confidence interval, 1.3-4.8) times more likely to recanalyze, for Δ based classification, and similarly for ε. These odds ratios were independent from intravenous or intra-arterial treatment. Final infarct volume was negatively correlated with both perviousness estimates (correlation coefficient, −0.39 for Δ and −0.40 for ε). Conclusions-This
Helminth parasites control host-immune responses by secreting immunomodulatory glycoproteins. Clinical trials and mouse model studies have demonstrated the potential of helminth-derived glycoproteins for the treatment of immune-related diseases, like allergies and autoimmune diseases. Studies are however hampered by the limited availability of native parasite-derived proteins. Moreover, recombinant protein production systems have thus far been unable to reconstitute helminth-like glycosylation essential for the functionality of some helminth glycoproteins. Here we exploited the flexibility of the N-glycosylation machinery of plants to reconstruct the helminth glycoproteins omega-1 and kappa-5, two major constituents of immunomodulatory Schistosoma mansoni soluble egg antigens. Fine-tuning transient co-expression of specific glycosyltransferases in Nicotiana benthamiana enabled the synthesis of Lewis X (LeX) and LDN/LDN-F glycan motifs as found on natural omega-1 and kappa-5, respectively. In vitro and in vivo evaluation of the introduction of native LeX motifs on plant-produced omega-1 confirmed that LeX on omega-1 contributes to the glycoprotein’s Th2-inducing properties. These data indicate that mimicking the complex carbohydrate structures of helminths in plants is a promising strategy to allow targeted evaluation of therapeutic glycoproteins for the treatment of inflammatory disorders. In addition, our results offer perspectives for the development of effective anti-helminthic vaccines by reconstructing native parasite glycoprotein antigens.
Progressive changes in dimensions of the endograft within the infrarenal neck could be detected on regular CTA scans before the complication became urgent in many patients.
Purpose: To evaluate the association between aortic curvature and other preoperative anatomical characteristics and late (>1 year) type Ia endoleak and endograft migration in endovascular aneurysm repair (EVAR) patients. Methods: Eight high-volume EVAR centers contributed 116 EVAR patients (mean age 81±7 years; 103 men) to the study: 36 patients (mean age 82±7 years; 31 men) with endograft migration and/or type Ia endoleak diagnosed >1 year after the initial EVAR and 80 controls without early or late complications. Aortic curvature was calculated from the preoperative computed tomography scan as the maximum and average curvature over 5 predefined aortic segments: the entire infrarenal aortic neck, aneurysm sac, and the suprarenal, juxtarenal, and infrarenal aorta. Other morphological characteristics included neck length, neck diameter, mural neck calcification and thrombus, suprarenal and infrarenal angulation, and largest aneurysm sac diameter. Independent risk factors were identified using backward stepwise logistic regression. Relevant cutoff values for each of the variables in the final regression model were determined with the receiver operator characteristic curve. Results: Logistic regression identified maximum curvature over the length of the aneurysm sac (>47 m −1 ; p=0.023), largest aneurysm sac diameter (>56 mm; p=0.028), and mural neck thrombus (>11° circumference; p<0.001) as independent predictors of late migration and type Ia endoleak. Conclusion: Aortic curvature is a predictor for late type Ia endoleak and endograft migration after EVAR. These findings suggest that aortic curvature is a better parameter than angulation to predict post-EVAR failure and should be included as a hostile neck parameter.
This retrospective validation study showed that apposition surfaces between an endograft and the infrarenal neck can be calculated accurately and with low variability. Determination of the (ap)position of the endograft in the aortic neck and detection of subtle changes during follow-up are crucial to determining eventual failure after EVAR.
Adequate EndoAnchor penetration into the aortic wall is less likely when the aortic neck diameter is large or when the neck contains significant mural calcium. No penetration of the EndoAnchor was the only factor predictive of postprocedural type IA endoleak. This study stresses the importance of careful selection of patients based on preoperative assessment of the infrarenal neck on CT angiography and emphasizes careful deployment of EndoAnchors into the aortic wall to improve successful treatment of type IA endoleaks.
Purpose: This study investigated the effect of different EndoAnchor configurations on aortic endograft displacement resistance in an in vitro model. Materials and Methods: An in vitro model was developed and validated to perform displacement force measurements on different EndoAnchor configurations within an endograft and silicone tube. Five EndoAnchor configurations were created: (1) 6 circumferentially deployed EndoAnchors, (2) 5 EndoAnchors within 120° of the circumference and 1 additional, contralateral EndoAnchor, (3) 4 circumferentially deployed EndoAnchors, (4) 2 rows of 4 circumferentially deployed EndoAnchors, and (5) a configuration of 2 columns of 3 EndoAnchors. An experienced vascular surgeon deployed EndoAnchors under C-arm guidance at the proximal sealing zone of the endograft. A constant force with increments of 1 newton (N) was applied to the distal end of the endograft. The force necessary to displace a part of the endograft by 3 mm was defined as the endograft displacement force (EDF). Two video cameras recorded the measurements. Videos were examined to determine the exact moment 3-mm migration had occurred at part of the endograft. Five measurements were performed after each deployed EndoAnchor for each configuration. Measurements are given as the median and interquartile range (IQR) Q1, Q3. Results: Baseline displacement force measurement of the endograft without EndoAnchors resulted in a median EDF of 5.1 N (IQR 4.8, 5.2). The circumferential distribution of 6 EndoAnchors resulted in a median EDF of 53.7 N (IQR 49.0, 59.0), whereas configurations 2 through 5 demonstrated substantially lower EDFs of 29.0 N (IQR 28.5, 30.1), 24.6 N (IQR 21.9, 27.2), 36.7 N, and 9.6 N (IQR 9.4, 10.0), respectively. Decreasing the distance between the EndoAnchors over the circumference of the endograft increased the displacement resistance. Conclusion: This in vitro study demonstrates the influence EndoAnchor configurations have on the displacement resistance of an aortic endograft. Parts of the endograft where no EndoAnchor has been deployed remain sensitive to migration. In the current model, the only configuration that rivaled a hand-sewn anastomosis was the one with 6 EndoAnchors. A circumferential distribution of EndoAnchors with small distances between EndoAnchors should be pursued, if possible. This study provides a quantification of different EndoAnchor configurations that clinicians may have to adopt in clinical practice, which can help them make a measured decision on where to deploy EndoAnchors to ensure good endograft fixation.
To identify preoperative anatomical aortic characteristics that predict seal failures after endovascular aneurysm sealing (EVAS) and compare the incidence of events experienced by patients treated within vs outside the instructions for use (IFU). Methods: Of 355 patients treated with the Nellix EndoVascular Aneurysm Sealing System (generation 3SQ+) at 3 high-volume centers from March 2013 to December 2015, 94 patients were excluded, leaving 261 patients (mean age 76±8 years; 229 men) for regression analysis. Of these, 83 (31.8%) suffered one or more of the following events: distal migration ⩾5 mm of one or both stent frames, any endoleak, and/or aneurysm growth >5 mm. Anatomical characteristics were determined on preoperative computed tomography (CT) scans. Patients were divided into 3 groups: treated within the original IFU (n=166), outside the original IFU (n=95), and within the 2016 revised IFU (n=46). Categorical data are presented as the median (interquartile range Q1, Q3). Results: Neck diameter was significantly larger in the any-event cohort vs the control cohort [23.7 mm (21.7, 26.3) vs 23.0 mm (20.9, 25.2) mm, p=0.022]. Neck length was significantly shorter in the any-event cohort [15.0 mm (10.0, 22.5) vs 19.0 mm (10.0, 21.8), p=0.006]. Maximum abdominal aortic aneurysm (AAA) diameter and the ratio between the maximum AAA diameter and lumen diameter in the any-event group were significantly larger than the control group (p=0.041 and p=0.002, respectively). Regression analysis showed aortic neck diameter (p=0.006), neck length (p=0.001), and the diameter ratio (p=0.011) as significant predictors of any event. In the comparison of events to IFU status, 52 (31.3%) of 166 patients in the inside the original IFU group suffered an event compared to 13 (28.3%) of 46 patients inside the 2016 IFU group (p=0.690). Conclusion: Large neck diameter, short aortic neck length, and the ratio between the maximum AAA and lumen diameters are preoperative anatomical predictors of the occurrence of migration (⩾5 mm), any endoleak, and/or aneurysm growth (>5 mm) after EVAS. Even under the refined 2016 IFU, more than a quarter of patients suffered from an event. Improvements in the device seem to be necessary before this technique can be implemented on a large scale in endovascular AAA repair.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.