Background In laboratory animals, exposure to most general anaesthetics leads to neurotoxicity manifested by neuronal cell death and abnormal behaviour and cognition. Some large human cohort studies have shown an association between general anaesthesia at a young age and subsequent neurodevelopmental deficits, but these studies are prone to bias. Others have found no evidence for an association. We aimed to establish whether general anaesthesia in early infancy affects neurodevelopmental outcomes. Methods In this international, assessor-masked, equivalence, randomised, controlled trial conducted at 28 hospitals in Australia, Italy, the USA, the UK, Canada, the Netherlands, and New Zealand, we recruited infants of less than 60 weeks' postmenstrual age who were born at more than 26 weeks' gestation and were undergoing inguinal herniorrhaphy, without previous exposure to general anaesthesia or risk factors for neurological injury. Patients were randomly assigned (1:1) by use of a web-based randomisation service to receive either awake-regional anaesthetic or sevoflurane-based general anaesthetic. Anaesthetists were aware of group allocation, but individuals administering the neurodevelopmental assessments were not. Parents were informed of their infants group allocation upon request, but were told to mask this information from assessors. The primary outcome measure was full-scale intelligence quotient (FSIQ) on the Wechsler Preschool and Primary Scale of Intelligence, third edition (WPPSI-III), at 5 years of age. The primary analysis was done on a per-protocol basis, adjusted for gestational age at birth and country, with multiple imputation used to account for missing data. An intention-totreat analysis was also done. A difference in means of 5 points was predefined as the clinical equivalence margin. This completed trial is registered with ANZCTR, number ACTRN12606000441516, and ClinicalTrials.gov, number NCT00756600. Findings Between Feb 9, 2007, and Jan 31, 2013, 4023 infants were screened and 722 were randomly allocated: 363 (50%) to the awake-regional anaesthesia group and 359 (50%) to the general anaesthesia group. There were 74 protocol violations in the awake-regional anaesthesia group and two in the general anaesthesia group. Primary outcome data for the per-protocol analysis were obtained from 205 children in the awake-regional anaesthesia group and 242 in the general anaesthesia group. The median duration of general anaesthesia was 54 min (IQR 41-70). The mean FSIQ score was 99•08 (SD 18•35) in the awake-regional anaesthesia group and 98•97 (19•66) in the general anaesthesia group, with a difference in means (awake-regional anaesthesia minus general anaesthesia) of 0•23 (95% CI-2•59 to 3•06), providing strong evidence of equivalence. The results of the intention-to-treat analysis were similar to those of the per-protocol analysis. Interpretation Slightly less than 1 h of general anaesthesia in early infancy does not alter neurodevelopmental outcome at age 5 years compared with awake-regional anaesthesia ...
Background Vital signs are usually recorded once every 8 h in patients at the hospital ward. Early signs of deterioration may therefore be missed. Wireless sensors have been developed that may capture patient deterioration earlier. The objective of this study was to determine whether two wearable patch sensors (SensiumVitals [Sensium Healthcare Ltd., United Kingdom] and HealthPatch [VitalConnect, USA]), a bed-based system (EarlySense [EarlySense Ltd., Israel]), and a patient-worn monitor (Masimo Radius-7 [Masimo Corporation, USA]) can reliably measure heart rate (HR) and respiratory rate (RR) continuously in patients recovering from major surgery. Methods In an observational method comparison study, HR and RR of high-risk surgical patients admitted to a step-down unit were simultaneously recorded with the devices under test and compared with an intensive care unit–grade monitoring system (XPREZZON [Spacelabs Healthcare, USA]) until transition to the ward. Outcome measures were 95% limits of agreement and bias. Clarke Error Grid analysis was performed to assess the ability to assist with correct treatment decisions. In addition, data loss and duration of data gaps were analyzed. Results Twenty-five high-risk surgical patients were included. More than 700 h of data were available for analysis. For HR, bias and limits of agreement were 1.0 (–6.3, 8.4), 1.3 (–0.5, 3.3), –1.4 (–5.1, 2.3), and –0.4 (–4.0, 3.1) for SensiumVitals, HealthPatch, EarlySense, and Masimo, respectively. For RR, these values were –0.8 (–7.4, 5.6), 0.4 (–3.9, 4.7), and 0.2 (–4.7, 4.4) respectively. HealthPatch overestimated RR, with a bias of 4.4 (limits: –4.4 to 13.3) breaths/minute. Data loss from wireless transmission varied from 13% (83 of 633 h) to 34% (122 of 360 h) for RR and 6% (47 of 727 h) to 27% (182 of 664 h) for HR. Conclusions All sensors were highly accurate for HR. For RR, the EarlySense, SensiumVitals sensor, and Masimo Radius-7 were reasonably accurate for RR. The accuracy for RR of the HealthPatch sensor was outside acceptable limits. Trend monitoring with wearable sensors could be valuable to timely detect patient deterioration. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New
Background and objectivesIntermittent vital signs measurements are the current standard on hospital wards, typically recorded once every 8 hours. Early signs of deterioration may therefore be missed. Recent innovations have resulted in ‘wearable’ sensors, which may capture patient deterioration at an earlier stage. The objective of this study was to determine whether a wireless ‘patch’ sensor is able to reliably measure respiratory and heart rate continuously in high-risk surgical patients. The secondary objective was to explore the potential of the wireless sensor to serve as a safety monitor.DesignIn an observational methods comparisons study, patients were measured with both the wireless sensor and bedside routine standard for at least 24 hours.SettingUniversity teaching hospital, single centre.ParticipantsTwenty-five postoperative surgical patients admitted to a step-down unit.Outcome measuresPrimary outcome measures were limits of agreement and bias of heart rate and respiratory rate. Secondary outcome measures were sensor reliability, defined as time until first occurrence of data loss.Results1568 hours of vital signs data were analysed. Bias and 95% limits of agreement for heart rate were −1.1 (−8.8 to 6.5) beats per minute. For respiration rate, bias was −2.3 breaths per minute with wide limits of agreement (−15.8 to 11.2 breaths per minute). Median filtering over a 15 min period improved limits of agreement of both respiration and heart rate. 63% of the measurements were performed without data loss greater than 2 min. Overall data loss was limited (6% of time).ConclusionsThe wireless sensor is capable of accurately measuring heart rate, but accuracy for respiratory rate was outside acceptable limits. Remote monitoring has the potential to contribute to early recognition of physiological decline in high-risk patients. Future studies should focus on the ability to detect patient deterioration on low care environments and at home after discharge.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.