Iatrogenic injury of the ureters is a feared complication of abdominal surgery. Zwitterionic near-infrared fluorophores are molecules with geometrically-balanced, electrically-neutral surface charge, which leads to renal-exclusive clearance and ultralow non-specific background binding. Such molecules could solve the ureter mapping problem by providing real-time anatomic and functional imaging, even through intact peritoneum. Here we present the first-in-human experience of this chemical class, as well as the efficacy study in patients undergoing laparoscopic abdominopelvic surgery. The zwitterionic near-infrared fluorophore ZW800-1 is safe, has pharmacokinetic properties consistent with an ideal blood pool agent, and rapid elimination into urine after a single low-dose intravenous injection. Visualization of structure and function of the ureters starts within minutes after ZW800-1 injection and lasts several hours. Zwitterionic near-infrared fluorophores add value during laparoscopic abdominopelvic surgeries and could potentially decrease iatrogenic urethral injury. Moreover, ZW800-1 is engineered for one-step covalent conjugatability, creating possibilities for developing novel targeted ligands.
Purpose: Incomplete oncologic resections and damage to vital structures during colorectal cancer surgery increases morbidity and mortality. Moreover, neoadjuvant chemoradiotherapy has become the standard treatment modality for locally advanced rectal cancer, where subsequent downstaging can make identification of the primary tumor more challenging during surgery. Near-infrared (NIR) fluorescence imaging can aid surgeons by providing realtime visualization of tumors and vital structures during surgery.Experimental Design: We present the first-in-human clinical experience of a novel NIR fluorescent peptide, cRGD-ZW800-1, for the detection of colon cancer. cRGD-ZW800-1 was engineered to have an overall zwitterionic chemical structure and neutral charge to lower nonspecific uptake and thus background fluorescent signal. We performed a phase I study in 11 healthy volunteer as well as a phase II feasibility study in 12 patients undergoing an elective colon resection, assessing 0.005, 0.015, and 0.05 mg/kg cRGD-ZW800-1 for the intraoperative visualization of colon cancer.Results: cRGD-ZW800-1 appears safe, and exhibited rapid elimination into urine after a single low intravenous dose. Minimal invasive intraoperative visualization of colon cancer through fullthickness bowel wall was possible after an intravenous bolus injection of 0.05 mg/kg at least 2 hours prior to surgery. Longer intervals between injection and imaging improved the tumor-tobackground ratio.Conclusions: cRGD-ZW800-1 enabled fluorescence imaging of colon cancer in both open and minimal invasive surgeries. Further development of cRGD-ZW800-1 for widespread use in cancer surgery may be warranted given the ubiquitous overexpression of various integrins on different types of tumors and their vasculature.
Background Carcinoembryonic antigen is overexpressed in colorectal cancer (CRC), making it an optimal target for fluorescence imaging. A phase I/II study was designed to determine the optimal imaging dose of SGM-101 for intraoperative fluorescence imaging of primary and recurrent CRC. Methods Patients were included and received a single dose of SGM-101 at least 24 h before surgery. Patients who received routine anticancer therapy (i.e., radiotherapy or chemotherapy) also were eligible. A dedicated near-infrared imaging system was used for real-time fluorescence imaging during surgery. Safety assessments were performed and SGM-101 efficacy was evaluated per dose level to determine the most optimal imaging dose. Results Thirty-seven patients with CRC were included in the analysis. Fluorescence was visible in all primary and recurrent tumors. In seven patients, no fluorescence was seen; all were confirmed as pathological complete responses after neoadjuvant therapy. Two tumors showed false-positive fluorescence. In the 37 patients, a total of 97 lesions were excised. The highest mean intraoperative tumor-to-background ratio (TBR) of 1.9 (p = 0.019) was seen in the 10-mg dose. This dose showed a sensitivity of 96%, specificity of 63%, and negative predictive value of 94%. Nine patients (24%) had a surgical plan alteration based on fluorescence, with additional malignant lesions detected in six patients. Conclusions The optimal imaging dose was established at 10 mg 4 days before surgery. The results accentuate the potential of SGM-101 and designated a promising base for the multinational phase III study, which enrolled the first patients in June 2019.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.